Sunteți pe pagina 1din 45

Fibcom

Configurations
Contents
1.Local Login by NSAP & IP
2.SFP Details
3.Software Loading
4.Commissioning
5.Cross connection creation- Lower order &
Attributes
6.Alarm details
7.Synchronization
Fibcom 6350 Login Port : MGT_W
Fibcom :6335 Login Port:6335
In CMCC Card:MGT1
Start the application: Extended craft
terminal
Starting and reading previously configured NE lists
NE Lists previously configured.
We have to add another NE
Click Add NE

Then Select the NE class


And give a NE Name
For 6350:
NE class is T6350_33
And give the NE Name
For 6335:
NE class is T6325_14
And give the NE Name
Select OSI-LAN for login via NSAP & TCP/IP for login via IP
Set the NSAP ID from CMCC card
CMCC Card position in 6350.
Eg:0082FC432D
NSAP ID position in CMCC card
We have to look it from bottom side.
Default IPs

1.6325/6335- 192.168.16.253
2.6345- 192.168.31.239
3.6350- 192.168.31.238
The NE created
ETEX DCN Settings
Right Click and Select Equipment View.
Reading status will be in progress.

If any issue it will stuck here without showing progress


Equipment View
SFP configuration and power level checking
Optical Ports
SFP Rating
Software Loading
Files names can be seen in file Management window
Select Firmware file and click set firmware option
Select software file and set Run Build option with Power
reset
Commissioning
Step1: Set NE Address
Step2: ECC configuration through DCC r/m
Step2: ECC configuration through 2Mbps line
Step3: Set CLNS tunnel configurations

Once communication between NE and sever is established all IPs of


client NEs under same GNE will be displayed in dynamic tunnels
Cross connection Creation- Lower order & Attributes
Step 1: Select the Destination (Electrical Ports)
Step 2: Select the Source by Pressing ctrl key
(multiple selection)
Step3:Click Connect
Bidirectional cross connection Icon
Cross connections
Disconnection 21st E1.

Cross connection can identify by the arrow


<->
Attributes
Attributes-Non Intrusive Monitoring
Alarm Details- External & Internal
1. Current Alarms
Internal Alarms
Aux Ports and Alarm configuration
Synchronization
Step 1: Assign traffic port input
Step 2: Set Priority
Station Clock input
Check temperature of modules
Thanks