Sunteți pe pagina 1din 12

ENERGY EFFICIENT AIR

CONDITIONING SYSTEM FOR


HOTEL APPLICATION

Guided By: Presented By:


Dr. Tushar Jadhav Akhil Joseph
Syed Quavi Ashraf
Mohd Faizal Khan
Problem Statement

Hotels spend as much as 30% of unneeded costs per room


each year for rented but unoccupied rooms.

It has often been observed that very little attention has


been paid to energy savings at the design stage.
Various Air Conditioning
systems
AC parameters are:
Window AC Split AC Cassette AC Package AC

Suitable for Small rooms with Any room Large indoor Telephone
window sill with/without spaces exchange
window equipment, clean
room work station

Noise Relatively on the Minimal noise Silent operation Relatively on the


higher side higher side

Capacity range 0.75 Ton to 2 Ton 0.8 Ton to 2 Ton 1 Ton to 4 Ton 3 Ton to 15 Ton

Advance feature Humidity control, Humidity control, Humidity control, Higher level of air
dust filter dust filter, dust filter, cleanliness
bacteria filter bacteria filter

Energy Consumed 2628W-7008W 2803W-7008W 3504W-14016W 10512W-52560W


Scope of work

To understand the requirement of Air conditioning for


hotel application, for Indian climatic condition.

To accomplish this ISHRAE and ASHRAE standards will be


referred.

Carry out feasibility study of 2 stage evaporative cooling


and suggest more efficient solution on working condition
and factors such as cost, space and water quality &
quantity.
2 stage evaporative cooling
system
First stage : Sensible heat
exchanger- Indirect
Evaporative cooling module

Second stage: Adiabatic heat-


exchanger
evaporative cooling
module
Psychrometric chart:
2 Stage Evaporative Cooling
System
Literature Review

Amazon Nagpur
Footwear-moulding-factory
school-auditorium-cooling
UMA Convertors
Somana State
ICC Devi Gaurav Tech Park
Hotriculture
Case Study:
ICC Devi Gaurav Tech Park
Atrium is about 1800ft with height 30ft and it serves as gate way
between the entrance and the elevator.
Management at ICC decided to go with energy VRF technology for
office air conditioning.
For conditioning they ruled out the use of any refrigerant based
system as it entails big investment and bigger maintenance cost.
OUTCOME:
Feasibility study on air washer system and HMX ambiator which is a
2-stage evaporative system was done.
ICC Devi Gaurav Tech Park
Paper:
Evaporative cooling system for storage
of fruit and vegetable.
Horticulture product are stored at lower temperature because of their highly
perishable in nature.
Pressing these type of foods in the fresh from demand that the chemical, bio-
chemical and physiological changes are restricted to be minimum by close
control of space temperature and humidity.
The high cost involved in developing cold storage or controlled atmosphere
country.
OUTCOME
Evaporative cooling system not only lowers the air temperature but also increase
the air moisture content in air.
Evaporative cooling system is well suited where, temperature is high and
humidity is low, water can be spread for this use and air movement is available.
Hotriculture
It is most suitable for short term storage of vegetable and fruits soon after
harvest.
Methodology (Tentative)

Carrying out feasibility study for a hotel.


Parameters to be considered:
Detailed layout of hotel
Physical dimension of space
Ambient condition
Number of duration of occupancy
Probable approach:
Energy Analysis of existing system
ISHRAE & ASHRAE standards for hotel
Action Plan
Thankyou