Sunteți pe pagina 1din 18

CDRH Software Regulation

John F Murray Jr..


Center for Devices & Radiological Health
US Food and Drug Administration
JFM@CDRH.FDA.GOV
Public Health and Software

The Quality of Pubic Health is highly


dependent on the Quality of Medical
Software

i.e. Medical Device Software, Clinical Information Systems,


Hospital Information Systems, Manufacturing Systems etc
What type of Quality do we
Want?

To get some perspective lets try what I call the


YB scale. [yugo vs. bmw]

I ask the following questions:

Where would Microsoft be on this scale?


Where do we want our software quality to be?
SOFTWARE IS DIFFERENT
Software Quality - Primarily a design issue
Custom developed components
Complexity
Structured development process plus testing
Dormant latent defects
Software is easy to change
Difficult to control changes
Significance of changes
SOFTWARE RECALLS
1983 - 1996
50
45
40
35
Number of Recalls

30
25
20
15
10
5
0
83 84 85 86 87 88 89 90 91 92 93 94 95 96
Year
SOFTWARE RECALLS
BY DEVICE PANEL
Radiology

InVitro Diagnostic

Cardiovascular

Anesthesiology 1983-91

General Hospital 1992-96

Other

0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0

Average Number of Software Recalls Per Year


Do the regulations recognize this need

Yes they do:

21 CFR 830.30
21 CFR 830.30 (a) (2) (i)
21 CFR 830.30 (g)
21 CFR 830.70 (i)
21 CFR 820.30 Design Controls
Each manufacturer of any Class II or Class
III device, and the Class I devices listed in
paragraph (a)(2) of this section, shall
establish and maintain procedures to control
the design of the device in order to ensure
that the specified design requirements are
meet.
21 CFR 820.30 (a)(2)(i)
Class I
The following Class I devices are subject to
design controls:
Devices automated with computer software
21 CFR 820.30 (g)
Design validation shall include software
validation and risk analysis where
appropriate
21 CFR 820.70 (i)
Automated processes
When computers or automated data processing
systems are used as part of production or the
quality system, the manufacturer shall validate
computer software for its intended use
according to an established protocol. All
software changes shall be validated before
approval and issuance. These validation
activities shall be documented.
What is the goal?
By Law: Medical Devices must be
reasonable safe and effective
By default: Software must be safe and
effective
Safe and Effective

It depends!
Cannot be easily defined
What is safe and effective software
Software Engineering
Risk Management
Quality System
CDRH Software Message
The law and regulations are written in broad
terms
Software should be engineered using:
Software Engineering
Risk Management
Quality System
This is the CDRH Software Message
Part 2
Regulatory
Overview

Partial FDA Software Timeline


1983 1985 1987 1989 1991 1993 1995 1997 1999

a c d e f g h j l p q t
b i k m r u
n s v
o
a. Guide to Computerized Systems in Drug Processing
b. Software Development Activities Reference Materials and Training Aids for Investigators
c. Draft FDA Policy for the Regulation of Computer Products
d. Draft Application of the Medical Device GMPs to Computerized Devices and Manufacturing Processes (Final 1992)
e. Draft Guidance for the Content and Review of 510(k) Notifications for Picture Archiving and Communications Systems(PACS)
and Related Devices
f. Reviewer Guidance for Computer Controlled Medical Devices Undergoing 510(k) Review
g. Draft Guideline for the Validation of Blood Establishment Computer Systems (Version 1 issued Oct-94)
h. Letter requiring submissions for Blood Bank Information Systems
i. Proposed Electronic Records: Electronic Signatures Rule
j. Glossary of Computerized System and Software Development Terminology
k. CADx Initiative
l. Telemedicine Related Activities Report
m. Public FDA Software Policy Workshop
n. Public Draft ODE Guidance for the Content of Premarket Submission for Medical Devices Containing Software
o. New Quality System Regulation
p. Do It By Design
q. Blood Bank Software Submission Guidance
r. Software Quality Audit Initiative
s. Final Rule Electronic Records: Electronic Signatures
t. General Principles of Software Validation - Draft Guidance
u. Guidance for Off-the-Shelf (OTS) Software Use in Medical Devices - Draft
v. Letter to Manufacturers Regarding the Year 2000 Computer Problem
Documents to date

General Principles of Software Validation; Final


Guidance for Industry and FDA Staff OC

Guidance for Off-the-Shelf Software Use in Medical


Devices; Final ODE

Guidance for the Content of Premarket Submissions


for Software Contained in Medical Devices; Final
Other Works
AAMI SW 68
IEC/ISO International Version of SW 68
AAMI TIR on Software Hazard
Management
AAMI TIR on Validation of High Risk
Software
AAMI TIR on Validation of Quality System
and Manufacturing Software
We have been at this a long time
Our first publication was 1991
We continue to support standards
development
We continue to support the development of
TIR
Training to come

S-ar putea să vă placă și