Sunteți pe pagina 1din 102

BSC6000

Operation and
Maintenance

www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.


Foreword
This course introduces basic concepts about operation and
maintenance of the BSC6000 system, and describes in
details about the operation steps and methods of using
LMT to perform the operation and maintenance of the BSC
and the BTS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
About This Course
BSC6000 LMT User Guide

BSC6000 System Description

Online Help

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
Objectives
Upon completion of this course, you will be able to:

Get a grasp of the task for daily operation and


maintenance

Get a good grasp of the BSC operation and maintenance

Get a good grasp of the BTS operation and maintenance

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
Contents
1. Introduction to O&M

2. System Management

3. BSC Maintenance

4. Site Maintenance

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
Log In the LMT
Function Description
Log in the LMT

Procedure
Step 1: Choose Start > All
Programs > Huawei Local
Maintenance Terminal >
BSC6000 Local
Maintenance Terminal

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Log In the LMT
Procedure
Step 2: Type the BSC name, BSC IP address, and remarks

Step 3: Click Add, and then click Close to return to the Login
dialog box

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
BSC6000 LMT Window

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Navigation Bar
Management Tree
Displaying all the sites, cells, and
TRXs in the BSC

Providing query, management, and


browse of the objects

Trace & Monitor


Tracing messages on the interfaces

Monitoring the CPU/DSP usage


and port bit error rates

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Overview of the Functions
Function Description Reference
System Online management 2 System Management
management BSC management
Parameter configuration management
BSC Query and maintenance of the BSC equipment, links, 3 BSC Maintenance
maintenance channel resources, and logs

Site Monitoring, query, and maintenance of sites, cells, TRXs, 4 Site Maintenance
maintenance and boards

Software Download, load, activation, and rollback of BSC 5 Software


management software, patches, license, and BIOS Management
Query of the board software
System Import and export of network parameters 6 System Configuration
configuration Cell data configuration in batches
Data backup and restoration
Data consistency check
Alarm Browse and query of alarms 7 Alarm Management
management Maintenance and configuration of the alarm box

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
Contents
1. Introduction to O&M

2. System Management

3. BSC Maintenance

4. Site Maintenance

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
Lock the LMT
Function Description
To manually lock the BSC6000
Local Maintenance Terminal

This operation can prevent


unsafe operations of
unauthorized users

Procedure
Choose System > Lock
System or Press F6

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
Change the Password
Function Description
To change the password of the
existing user
All the users except the guests can
change their passwords. The
changed password takes effect when
you log in to the GBAM next time
Procedure
Choose System > Change
Password

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
Manage User Information
Function Description
To add an external user account
and set the related information
To delete an external user
account
To modify an external user
account

Procedure
Choose System > User
Management

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
Manage BSC Information
Function Description
To add/delete a BSC

To modify BSC
information

Procedure
Choose System > BSC
Management

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
Manage the System Configuration
Function Description
To set the default information
about system auto action

Such information includes


system auto lock time,
command timeout, maximum
lines in progress window, and
cell LAC and CI display mode

Procedure
Choose System > System
Configuration

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
Contents
1. Introduction to O&M

2. System Management

3. BSC Maintenance

4. Site Maintenance

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
Query Board Information
Function Description
To query the following information:
Board status: The board status consists of the subrack number,
slot number, management status, operation status, active/standby
status, availability status, and alarm status
Board information: Board delivery information
Board property: Board temperature

Procedure
Choose BSC Maintenance > Maintain Device > Query BSC
Board Information

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
Query Board Information

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page19
Switchover BSC Board
Function Description
To transfer the services carried in the active board to the
standby board when the active board fails

Be cautious when switching over a board. If the board


switchover fails, the related links will be disrupted and the
service data will be lost

Procedure
Choose BSC Maintenance > Maintain Device > Switch Over
BSC Board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
Switchover BSC Board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
Reset BSC Board
Function Description
To reset a BSC board , to reset the CPU or to reset the DSP

Be cautious when resetting a board. If the standby board of the


board to be reset is not installed or fails, the services carried on
this board will be disrupted when the board is reset

Procedure
Choose BSC Maintenance > Maintain Device > Reset BSC
Board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
Reset BSC Board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
Query the CPU/DSP Usage
Function Description
To query the real-time usage of the CPU and the DSP

Procedure
Choose BSC Maintenance > Maintain Device > Query
CPU/DSP Usage

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
Query CPU/DSP Status
Function Description
To query the status of the CPU in the GXPUM and the GXPUC
or the status of the DSP in the GDSUC

The status includes availability status, management status,


standby status, operation status, and alarm status

Procedure
Choose BSC Maintenance > Maintain Device > Query
CPU/DSP State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
Query CPU/DSP Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
Reset the GBAM Process
Function Description
To reset the GBAM process
when the GBAM is faulty

Procedure
Choose System > Reset
GBAM Process

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
Maintain the Fan Box
Function Description
To query the attributes of the fan box and reset the fan box

The fan box is used to maintain the working temperature of the


BSC boards. To maintain the normal running of the fan box, you
need to monitor and maintain the fan box in real time

Procedure
Choose BSC Maintenance > Maintain Device > Maintain Fan
Box

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
Maintain the Fan Box

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
Reset the Power Distribution Box
Function Description
To reset the power distribution box

The power distribution box provides power supply to the cabinet.


When the power distribution box fails, reset it to recover its
functions such as power detection and over voltage protection

Procedure
Choose BSC Maintenance > Maintain Device > Reset Power
Box

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
Reset the Power Distribution Box

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
Reset Subrack
Function Description
To reset all the boards in a subrack
When the control subrack of the fan box or power distribution
box is reset, the fan box or power distribution box is also reset
The reset of a BSC6000 subrack disrupts the existing services
of the system. Be cautious when resetting a subrack

Procedure
Choose BSC Maintenance > Maintain Device > Reset
Subrack

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
Reset Subrack

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
Query Board Clock Status
Function Description
To query the status of the
input clock of a board
The clock types for
different boards is
different

Procedure
Choose BSC
Maintenance > Maintain
Device > Query Board
Clock Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
Query BSC Clock Reference Status
Function Description
To query the work status
of the existing system
clock

Procedure
Choose BSC
Maintenance > Maintain
Device > Query BSC
Clock Reference Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
Maintain LAPD Links
Function Description
To query the LAPD link status.
On the basis of the LAPD link
status, you can block, unblock,
perform loopback tests, and
reset the LAPD link

Procedure
Choose BSC Maintenance >
Maintain Transmission and
Signaling > Maintain LAPD
Link

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page36
Query the Status of the Ater OML
Function Description
To query the status of the
HDLC link

Procedure
Choose BSC Maintenance
> Maintain Transmission
and Signaling > Query Ater
OML State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
Maintain the SCCP
Function Description
To query the maintenance
information about the Signaling
Connection Control Part (SCCP)
The SCCP maintenance information
includes Destination Signaling Point
(DSP) status, SCCP status, and
congestion status of the SCCP
Procedure
Choose BSC Maintenance >
Maintain Transmission and
Signaling > Maintain SCCP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
Maintain MTP3 Links
Function Description
To query the link status, route status, DSP status of MTP3 links

To activate, deactivate, inhibit, or enable MTP3 links on the


basis of the query result

Procedure
Choose BSC Maintenance > Maintain Transmission and
Signaling > Maintain MTP3 Link

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
Maintain MTP3 Links

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
Maintaining MTP2 Links
Function Description
To query the physical link status of the MTP2

Procedure
Choose BSC Maintenance > Maintain Transmission and Signaling
> Query MTP2 Link State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
Query the Interface Board Port State
Function Description
To query the configuration status, work mode, and availability of
E1/T1 ports

Procedure
Choose BSC Maintenance > Maintain Transmission and
Signaling > Query Interface Board Port State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page42
Query the Interface Board Port State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
Maintain the Interface Board Port
Loopback
Function Description
To query the port number,
loopback status, and loopback
remaining time

To start or stop the loopback on


the basis of the query result

Procedure
Choose BSC Maintenance >
Maintain Transmission and
Signaling > Interface Board
Port Loopback

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
Maintain the Port Timeslot Loopback
Function Description
To query the timeslot number,
loopback mode, and loopback
status

To start or stop the loopback on


the basis of the query result

Procedure
Choose BSC Maintenance >
Maintain Transmission and
Signaling > Interface Board Port
Timeslot Loopback

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
Query Abis Interface Status
Function Description
To query the timeslot information, such as timeslot number,
timeslot type, and timeslot status, of the Abis interface circuits

Procedure
Choose BSC Maintenance > Maintain User Resource >
Query Abis Interface Timeslot State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
Query Abis Interface Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page47
Query Ater Interface Status
Function Description
To query the timeslots of the Ater interface
circuits

The Ater interface is the interface between


the local end and the remote end of the
BSC6000. It is an internal interface

Procedure
Choose BSC Maintenance > Maintain
User Resource > Query Ater Interface
Timeslot State

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
Maintain the A Interface
Function Description
To query the circuit status on
the A interface
To block, unblock, and reset
the A interface circuits based
on the query results

Procedure
Choose BSC Maintenance >
Maintain User Resource >
Maintain A Interface Circuit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
Maintain the Pb Interface
Function Description
To query the circuit status on the Pb interface

To block, unblock, and reset the Pb interface circuits based on


the query results

The Pb interface is the interface between the Packet Control


Unit (PCU) and the BSC. It is a Huawei internal interface

Procedure
Choose BSC Maintenance > Maintain User Resource >
Maintain Pb Interface Circuit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50
Maintain the Pb Interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page51
Query TC Resources
Function Description
To query the channel status and channel usage of the GDSUC

To query the service type, coding and decoding rate, and


loopback status of the DSP

Procedure
Choose BSC Maintenance > Maintain User Resource >
Query TC Resource .

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page52
Query TC Resources

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page53
Query Call Resources
Function Description
To query the call resource
information, such as service
type, cell number, and TRX
number, of a user

Procedure
Choose BSC Maintenance
> Maintain User Resource
> Query Call Resources

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page54
Remote Speech Loopback
Function Description
To start or stop the remote speech
loopback
To query the status of all the existing
remote speech loopback
The remote speech loopback is used
to locate external speech problems
Procedure
Choose BSC Maintenance >
Maintain User Resource > Remote
Speech Channel Loopback

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page55
Test the Inner Speech Channel
Function Description
To test the inner speech channel

The inner speech channel test is


used to locate the inner speech
problems

Procedure
Choose BSC Maintenance >
Maintain User Resource >
Test Internal Speech Channel

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page56
Set the DSP Preferential
Assignment
Function Description
To set the DSP preferential
assignment

To query the status of the speech


channels

The DSP preferential assignment can


avoid large-scale tests

Procedure
Choose BSC Maintenance >
Maintain User Resource > Set DSP
Preferential Assignment

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page57
Set DSP Speech Channel
Loopback
Function Description
To start the DSP speech
channel loopback

Procedure
Choose BSC Maintenance
> Maintain User Resource
> DSP Speech Channel
Loopback

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page58
Contents
1. Introduction to O&M

2. System Management

3. BSC Maintenance

4. Site Maintenance

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page59
Download the BTS Software
Function Description
To download the BTS software from the LMT to the GBAM
through the FTP Server

Procedure
Choose BTS Maintenance > Download BTS Software

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page60
Configure the BTS Software
Function Description
To set the file type, file name, version number, BTS type for the
downloaded software before BTS software loading

Procedure
Choose BTS Maintenance > Configure BTS Software

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page61
Load the BTS Software
Function Description
To write the configured file into the flash of the BTS

To check whether the file is consistent with the version number


configured

Procedure
Choose BTS Maintenance > Load BTS Software

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page62
Load the BTS Software

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page63
Activate the BTS Software
Function Description
To obtain the required data or software information from the
flash to boards

The BTS software must be activated before running

Procedure
Choose BTS Maintenance > Activate BTS Software

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page64
Activate the BTS Software

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page65
Query BTS Running Status
Function Description
To query the running status of the BTSs controlled by a BSC

Procedure
Choose BTS Maintenance > Query BTS Running Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page66
Query the Board Running Software
Version
Function Description
To query the board running software version of the BTS

Procedure
Choose BTS Maintenance > Query Board Running Software
Version

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page67
Query the Board Match
Function Description
To query whether the actual board type matches the configured
board type
Procedure
Choose BTS Maintenance > Query Board Match

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page68
Query the Board Bar Code
Function Description
To query the bar codes of BTS boards

The bar code of a board indicates the manufacturing information


of the board. When errors occur in several boards, query the bar
codes to check whether the boards produced in a batch are
faulty

Procedure
Choose BTS Maintenance > Query Board Bar Code

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page69
Query the Board Bar Code

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page70
Query BTS Attributes
Function Description
To query BTS attributes, such as Manufacturer ID, Software
Configuration, and Hardware Configuration
Procedure
Choose BTS Maintenance > Query BTS Attributes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page71
Reset the BTS in Levels
Function Description
To reset a or a cell or site at level 3 or level 4
Be cautious about BTS reset. The reset of a BTS leads to site
initialization, data reloading, and service disruption
Procedure
Choose BTS Maintenance > Reset BTS in Levels

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page72
Browse BTS Initialization Process
Messages
Function Description
To browse the initialization process of all the sites controlled by
a BSC

The initialization process message shows the site reset. If the


initialization fails, this message shows the failure cause

Procedure
Choose BTS Maintenance > Browse BTS Initialization
Process Message

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page73
Browse Initialization Process
Messages

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page74
Modify Management Status
Function Description
To lock, unlock, or shut down a
cell, TRX, or channel
The status of an object can be
modified only when its upper-
level objects are unlocked

Procedure
Choose BTS Maintenance >
Modify Management Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page75
Perform Force Handover
Function Description
To hand over a call from
one cell to another cell
to ensure that no call
drops occur during site
maintenance

Procedure
Choose BTS
Maintenance > Force
Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page76
Monitor Channel Status
Function Description
To monitor the status of channels and sub channels

Procedure
Choose BTS Maintenance > Monitor Channel Status

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page77
Monitor the Channel Interference Band
Function Description
To monitor the interference band of idle channels

The interference band is the uplink interference level reported by the


BTS to the BSC through an RF RESOURCE INDICATION message.
The interference band is divided into five grades, as listed in Table 4-2

If the interference band of an idle channel is in grades 4 or 5, the


channel interference exists

Procedure
Choose BTS Maintenance > Monitor Channel Interference Band

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page78
Monitor the Channel Interference Band

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page79
Query BTS Running Software Version
Function Description
To query the software version of a BTS

Procedure
Choose BTS Maintenance > Maintain Site > Query BTS
Running Software Version

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page80
Test Site
Function Description
To check the BTS status by testing the running status of all the
boards in a site

Procedure
Choose BTS Maintenance > Maintain Site > Test BTS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page81
Monitor BTS Resources
Function Description
To monitor the parameters, such as CPU usage, RAM usage,
Mother-tier voltage, and Temperature inside the cabinet, of the
TMU and the TRX boards

Procedure
Choose BTS Maintenance > Maintain Site > Monitor BTS
Resource

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page82
Monitor BTS Resources

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page83
Monitor Environment
Function Description
To monitor the environment, for example, to reset or clear an alarm
and query the temperature and humidity
Procedure
Choose BTS Maintenance > Maintain Site > Monitor
Environment

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page84
Send the System Information to a Cell
Function Description
To send the system information to a cell

Procedure
Choose BTS Maintenance > Maintain Cell > Send Cell System
Message

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page85
Query Frequency Scan
Function Description
To query frequency scan

Procedure
Choose BTS Maintenance > Maintain Cell > Query
Frequency Scan

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page86
Configure Frequency Scan
Function Description
To set the start time and duration of frequency scan

When the GBAM time is in the scan duration, the frequency


scan starts and reports the scan results periodically. When the
GBAM time is not in the scan duration, the frequency scan stops

Procedure
Choose BTS Maintenance > Maintain Cell > Configure
Frequency Scan

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page87
Configure Frequency Scan

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page88
Test TRX Performance
Function Description
To test the performance of all the TRXs or selected TRXs in a site
The test items include interference level and power level
Procedure
Choose BTS Maintenance > Maintain TRX > Test TRX
Performance

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page89
Query the Power Mode
Function Description
To query the power mode of TRXs

Procedure
Choose BTS Maintenance >
Maintain TRX > Query Power
Mode.

Set Location. Select the TRXs in


the Candidate TRXs box and add
them to the Selected TRXs box,
and then click Query

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page90
Query the Automatic Power Correction
Type
Function Description
To query the automatic power
correction type

Procedure
Choose BTS Maintenance >
Maintain TRX > Query
Automatic Power Correction
Type.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page91
Test TRX Loopback
Function Description
To test TRX loopback

The TRX loopback test


consists of BIU Loop Test
and TRX Self Test

Procedure
Choose BTS Maintenance
> Maintain TRX > Test TRX
Loopback

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page92
Test Channel Loopback
Function Description
To test the channel loopback

The BTS channel loopback


test consists of TRX RF Self
Loop Test and BIU Loop Test

Procedure
Choose BTS Maintenance >
Maintain TRX > Test
Channel Loopback

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page93
Test Idle Timeslots
Function Description
To test idle timeslots

In the network optimization process, the network has to be


manually set to maximum interference mode to obtain the
maximum interference of the entire network. All the idle
timeslots in a specific area are set to send idle frames to
achieve this maximum interference mode

Procedure
Choose BTS Maintenance > Maintain TRX > Test Idle
Timeslot

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page94
Test Idle Timeslots

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page95
Test the CODEC Mode
Function Description
To test the CODEC mode

Procedure
Choose BTS Maintenance > Maintain TRX > Test CODEC
Mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page96
Reset TRX
Function Description
To reset a TRX

Procedure
Choose BTS Maintenance > Maintain TRX > Reset TRX

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page97
Query Board Information
Function Description
To query board information,
such as the software version
and hardware version

Procedure
Choose BTS Maintenance
> Maintain Board > Query
Board Information

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page98
Maintain the Clock
Function Description
To query and set clock
parameters, such as clock
mode, trace mode,
current value, and
calibration value

Procedure
Choose BTS
Maintenance > Maintain
Board > Maintain Clock

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page99
Reset a Board
Function Description
To reset a board, such as the CDU, TRX, TMU, PBU, TEU, TES,
or EAC

Procedure
Choose BTS Maintenance > Maintain Board > Reset Board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page100
Summary
In this course we have learned
The daily operation and maintenance of BSC6000

The BSC operation and maintenance of BSC6000

The BTS operation and maintenance of BSC6000

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page101
Thank you
www.huawei.com

S-ar putea să vă placă și