Sunteți pe pagina 1din 28

1.

Production Capacity HYUNDAI

1) Annual Production Capacity : 28,000MVA

2) Maximum Capacity : up to 800MVA(3 phase)

3) Maximum Voltage : up to 765kV, 2050 BIL

4) Factory Space : 16,800m

5) Manpower for Transformer factory


- 55 Engineers
- 340 Skilled Workers

2
2. Production Range HYUNDAI

1) Power Transformer

2) Distribution Transformer

3) Cast resin Transformer

4) Special Purpose Transformer


Rectifier Transformer
Furnace Transformer
Dry type Transformer
Shunt Reactor
Mobile Transformer

3
3. Quality Assurance (ISO 9001)
HYUNDAI

1) Original Date of Issue : July of 1989

2) Registered Parts of Quality Assurance

Transformer Design and Development


Production and Testing

Installation and Service

4
4. Applicable Standard
HYUNDAI

1) IEC 76 (For Europe and Asia)

2) ANSI C57.12.00 (For America)

3) CAN/CSA-C88-M90 (For Canada)

4) AS 2374 (For Australia)

5) ES 140 (For Korea)

5
5. Short Circuit Test
HYUNDAI

1) Major Performance Record of Short Circuit Test


Test of
No. Specification of Transformer Test Date Tap Change Customer

Generating Transformer
1 Sept. 1995 N.L.T.C PUD in USA
3PH 6/64/85/106/119MVA 230/14.8kV YNd1

Power Transformer
2 Nov. 1989 O.L.T.C KEPCO in Korea
3PH 45/60MVA 154/23kV Ynyno(d)

Power Transformer In-Chon Iron &


3 Nov. 1986 O.L.T.C
3PH 35/44MVA 154/23kV YNd1 Steel in Korea

Distribution Transformer
4 Dec. 1986 O.L.T.C PUB in Singapore
3PH 10MVA 22/6.6kV Ynynod(d)

Power Transformer
5 Dec. 1986 O.L.T.C WAPDA in Parkistan
3PH 20/26MVA 132/11.5kV Dyn11

6
5. Short Circuit Test
HYUNDAI

2) Detailed Explanation for the Short Circuit Test Performed to the


230kV Transformers for Rocky Reach Project

Customer : Public Utility District No.1 of Chelan County in U.S.A

Project : Replacement for Rocky Reach Dam Transformer

Transformer Rating
3phase 60Hz 119MVA 14.8/230kV Step-up Transformer
Basic Impulse Level on H.V Side : 900kV
Standard : ANSI C57.12.00

Tested and Certified by Korea Electrotechnology Research Institute

7
Picture of Short Circuit Test
HYUNDAI

8
6. Development of Transformer
HYUNDAI

1) 765kV Transformer
1PH 60Hz 2 x 333.3MVA 765/345kV
OLTC type Auto transformer (Bil : 2050kV) : 1998 Developed
1PH 60Hz 204MVA 20.9/765kV
NLTC type Step-up transformer (Bil : 2050kV) : 1999 Developed
1PH 60Hz 370MVA 765/345/23kV
NLTC type Auto transformer (Bil : 2050kV) : 1999 Developed

2) Gas Insulated Transformer


1PH 60Hz 20MVA 154/23kV OLTC Type Transformer
(Under Development)

9
6. Development of Transformer
HYUNDAI

3) Mobile Transformer (Developed)


3PH 60Hz 40MVA 154/23kV (1996)
"H" Class insulation (95C temp. rise)
Comparison of "A" and "H" class insulation
Insulation No Load Loss Load Loss Weight

A Class 31 kW 241 kW 35 TON

H class 23 kW 434kW 25 TON

Remark 74% 180% 71%

Transportation with trailer


Weight : 39.4 Ton
Size(m) : L8.6 x W2.9 x H3.9

10
Picture of 154kV 40MVA Mobile Transformer-Using H Class
Insulation (NOMAX Paper) HYUNDAI

11
7. Major International Clients and Performances
HYUNDAI
1) North America
Country Client Rating of Transformer
Alumnium Company of America 161/13.8kV, 93MVA
Los Angeles Department of Water and Power 34.5/5.04kV, 16MVA
Chelan Country 230/14.8kV, 119MVA
Black & Veatch 230/15.75kV, 315MVA
General Electric Company 138/13.8kV, 125MVA
Baltimore Gas & Electric 13.8/2 X 3.9kV, 20MVA
CRS Sirrine Engineers 69/13.8KkV, 90MVA
Zurn Nepco 132/11.5kV, 90MVA
Westinghouse 138/13.8kV, 150MVA
U.S.A Florida Power Corporation 16/230kV, 235MVA
Colorado River Commission of Nevada 230/69kV, 200MVA
Sacramento Municipal Utility District 230/69/13.8kV, 200MVA
Duke Fluor Daniel 115/11kV, 93MVA
Babcock & Wilcox Engineering 138/15.5kV, 160MVA
Lower Colorado River Authority 138/22.8kV, 490MVA
Puget Sound Energy 230/117.8kV, 325MVA
National Electrical System Inc. 115/13.2kV, 115MVA
City of Tacoma 115/13.8kV, 56MVA
New York Power Authority 230/13.2kV, 86MVA
12
7. Major International Clients and Performances
HYUNDAI

2) South America
Country Client Rating of Transformer

230/34.5kV, 50MVA
Interconexion Electrical S.A
500/230/34.5kV, 150MVA
Colombia
EPM 230/115/46kV, 90MVA

ESSA 115/34.5/13.8kV, 40MVA


Trinidad Trinidad & Tobogo Electricity Commission (TTEC) 33/12kV, 6MVA
& Tobago
Panama CELMEC 115/13.8kV, 50MVA

Chile Chilectra 230/110/13.2kV, 130MVA

Peru Proyecto Ampliacion de LA S. E. 220/60/10kV, 50MVA

Guatemala JBV Guatemala, LCC 230/13.8kV, 150MVA

Venezuela ENELVEN 200/115/13.8kV, 200MVA

Puerto Rico Abengoa 115/2 X 13.8kV, 300MVA


Brazil CERJ 138/13.8kV, 33.3MVA

13
7. Major International Clients and Performances
HYUNDAI

3) Asia
Country Client Rating of Transformer

Japan Tokyo Electric Power Company 66/6.9kV, 20MVA

Singapore Public Utilities Board (PUB) 22/6.6kV, 10MVA

Tenaga Nasional Bhd. (TNB) 275/132kV, 240MVA


Malaysia
Sarawak Electricity Supply Corp. (SESCO) 275/230kV, 250MVA

Sabah Electricity Board (SEB) 275/132kV, 180MVA

Indonesia Perusahaan Umum Listrik Negara (PLN) 150/20kV, 100MVA

National Power Corp (NPC) 230/115/13.8kV, 300MVA


Philippines
Manila Electric Company (MERALCO) 110/34.5/13.8kV, 83.3MVA

Vietnam Electricity of Vietnam (EVN) 230/121/22kV, 63MVA

Vietnam POSCO Steel Co. 110/6.6kV, 20MVA

Bangladesh Bangladesh Power Development Board (BPDB) 240/140kV, 150MVA

14
7. Major International Clients and Performances
HYUNDAI

3) Asia
Country Client Rating of Transformer

Electricity Generating Authority of Thailand (EGAT) 115/34.5/11kV, 50MVA


Thailand
Metropolitan Electricity Authority (MEA) 60/11.5kV, 60MVA

Provincial Electricity Authority (PEA) 115/23.1kV, 40MVA

Myanmar Myanmar Electric Power Enterprise (MEPE) 132/33/11kV, 30MVA

Water and Power Development Authority (WAPDA) 230/11kV, 125MVA


Parkistan
Karachi Electricity Supply Corporation (KESC) 132/11kV, 40MVA

D. G Khan Cement Company 132/6.3kV, 20/26MVA

India Oil and Natural Gas Commission (ONGC) 6.6/0.433kV


2000KVA (Cast Resin Type)

Srilanka Ceylon Electricity Board (CEB) 132/33kV, 31.5MVA

15
7. Major International Clients and Performances
HYUNDAI

4) Middle East
Country Client Rating of Transformer

Electricity Corporation 132/33kV, 60MVA

SCECO-Central 132/13.8kV, 100MVA


Saudi Arabia
SCECO-East 230/115/34.5kV, 400MVA

Tabouk Electricity Company 132/13.8kV, 100MVA


Arabian American Oil Company 66/13.8kV, 67MVA

Iraq State Organization of Electricity (SOE) 400/138.6/11kV, 250MVA

Yemen Yemen General Electricity Corp. (YGEC) 132/33kV, 25MVA

Lebanon Council for Development & Reconstruction 66/20-11kV, 40MVA

Dubai Electricity Company 33/11kV, 15MVA


U.A.E
Water and Electricity Department 11/0.433kV, 1500KVA
(Cast Resin Type)

Oman Ministry of Electricity and Water 33/11kV, 20MVA


Shunt Reactor
Turkey Turkiye Electric Kurumu
154kV, 5MVAR

16
7. Major International Clients and Performances
HYUNDAI

5) Oceania and Canada


Country Client Rating of Transformer

Australia Pacific Power (The Electricity Commission of 132/11kV, 20MVA


New Sourth Wales) 132/69/11kV, 20MVA
Power Link (Queensland Electricity Commission) 230/34.5kV, 80/120MVA
BHP Engineering Pty Ltd. 132/66/11kV, 120MVA
Shortland County Council 66/13.8kV, 67MVA
New Zealand New Zealand Aluminium Smelter Ltd. (NZAS) 220/11kV, 50MVA
Papua New The Electricity Commission of P.N.G 132/66kV, 20MVA
Guniea
British Columbia Hydro & Power Authority 512.5/242/25.2kV, 500MVA
Richmond Hill Hydro 212.5/2 X 28kV, 125MVA
Manitoba Hydro 114.3/2 X 12.47kV, 50MVA
Alberta Power Ltd. 144/25kV, 50MVA
Canada Howe Sound Pulp & Paper Ltd. 230/13.8kV, 62MVA
Yukon Electrical Company 138/13.8kV, 40MVA
Stone & Webster Canada Ltd. 243/2 X 13.8kV, 171MVA
Transalta Vtilities 260/72kV, 224MVA
Agra Monenco/ Aurora Mine 260/72kV, 116.2MVA
Saskatchewan Power Corporation 128/24.9kV, 29.8MVA

17
7. Major International Clients and Performances
HYUNDAI

6) Europe
Country Client Rating of Transformer

Switzerland ABB Power Generation Ltd. 220/21kV, 420MVA

Germany Siemens AG 132/6.9kV, 40/45MVA

Denmark Johs Gran-Hassen Product Ltd. 220/60/10kV, 40/50MVA

7) Africa
Country Client Rating of Transformer

Egypt Egyptian Electricity Authority (EEA) 21/220kV, 395MVA

Arco Steel 220/22.5kV, 80MVA

Ethiopia Ethiopian Electric Light and Power Authority (ELPA) 132/15kV, 22MVA
Heavy Industries Secretariat Tripoil Socialist
Libya 11/225kV, 105MVA
Peoples Libyan Arab Jamshebreya

18
8. Major Production Facilities
HYUNDAI

1) Over-Head Crane (300 TON x Span 38m)

2) Vacuum Vaporization Facility (L 13m x W 4.8m x H 6.6m)

3) Air - Cleaning Facility (L 45m x W 40m x H 7m)

4) Oil Filtering Machine (8,00 litter / hour)

5) Motorized Transporter for Test (400 TON x 2EA)

6) Core Binding Machine (40 TON x W 8m)

7) Core Lamination Table (120TON)

19
9. Major Testing Facilities
HYUNDAI

1) Impulse Generator System ( 400KV / 600KJ )

2) Oscillation Lightning Impulse Test System (1,800KV / 90KJ )

3) AC Series Resonant Voltage Test System


(1,200KV / 4,800KVA )

4) AC Power Generator System ( 23MVA x 2sets )

5) AC Power Generator System ( 23MVA x 2sets )

6) Condenser Bank ( 158KV, 225MVAR )

7) Transformer Loss Measuring System (200KV / 4,000A )

20
10. Major Manufacturing Process
HYUNDAI

1) Winding Works

21
10. Major Manufacturing Process
HYUNDAI

2) Core lamination

22
10. Major Manufacturing Process
HYUNDAI

3) View of Core Structure (After Completion of Core Lamination)

23
10. Major Manufacturing Process
HYUNDAI

4) Coil Insertion Works

24
10. Major Manufacturing Process
HYUNDAI

5) View of Core and Coil Assembly Works

25
10. Major Manufacturing Process
HYUNDAI

6) Drying Works in Vacuum Vaporization Facility

26
10. Major Manufacturing Process
HYUNDAI

7) Completion of Core & Coil Assembly

27
10. Major Manufacturing Process
HYUNDAI

8) Factory Test

28

S-ar putea să vă placă și