1. WHAT IS THE MEANING OF A CONTROL
SYSTEM?
Within a System, the outputs and inputs are co-related in
such a way, to the point that the yield amount or variable
is controlled by input amount, at that point, such a
framework is called as a Control System.
The output amount is termed as a controlled variable or
response and the input amount is called command signal
or excitation.

Saytooloud/Interview-Tips
2. WHAT DO YOU UNDERSTAND BY A
HOLDING CURRENT?
At the point when SCR is conducting current in a forward
conduction state, SCR will come back to forward blocking
state when the anode current or forward current falls
beneath a low level termed as a Holding current

Saytooloud/Interview-Tips
Note: Latching current and Holding current is not one.
Latching current is related to the turn-on process of the
SCR though holding current is related with the turn off
procedure. In general, holding current will be somewhat
lesser than the latching current.

Saytooloud/Interview-Tips
3. WHAT ADVANTAGES DOES THE
FREEWHEELING DIODE PROVIDE A FULL
WAVE RECTIFIER?
It lessens the harmonics and it likewise decreases sparking
and arching over the mechanical switch such that it
diminishes the voltage spike found in an inductive load.

Saytooloud/Interview-Tips
4. WHAT IS THE SF6 CIRCUIT BREAKER?
SF6 is Sulpher hexa Flouride gas.. on the off chance that
this gas is utilized as arc quenching medium in a Circuit
breaker implies SF6 CB.

Saytooloud/Interview-Tips
5. WHAT IS THE DIFFERENCE BETWEEN
MCCB AND MCB? WHERE CAN IT BE
UTILIZED?
MCB happens to be a miniature circuit breaker which is
thermally operated and use for short circuit in little
current rating circuit. MCCB molded case circuit breaker
and is thermal operated for overload current and
magnetic operation for an instant trip in short circuit
condition and under recurrence might be inbuilt.
Ordinarily, it is utilized where the normal current is in
excess of 100A.

Saytooloud/Interview-Tips
Include these as a part of your interview preparation
process. For best interview tips and techniques, do visit
the SayTooLoud page.

Saytooloud/Interview-Tips
THANK YOU...