Sunteți pe pagina 1din 25

- Table of Contents -

PART. 1 GENERAL PART. 2 TECHNICAL

1. Specification 1-1 1. Unit Explanation 2-1

2. Composition 1-4 2. System Block Diagram 2-6

3. Configuration 1-5 3. Signal Flow 2-7

4. Test Point & Output 2-8


1. Specification

Type Dual Frequency System


Range 328.6 to 335.4MHz, 50kHz Spacing
Frequency
Stability ±0.001%
DDS Synthesizer Controlled Difference between Course and Clearance is 5~14K
For CSB Course Max 5W, Normal 3W (control step:100mW)
For SBO Course Max 200mW, Normal 60mW (control step:1mW)
Output Power For CSB Clearance Max 600mW, Normal 300mW (control step:1mW)
Harmonic radiation & Spurious 0.25㎼(-36dBm) Max.
Stability ±0.2dB(At the operating frequency)
Type DDS syn.
Frequency 90Hz(±1%), 150Hz(±1%)
Depth of modulation(90Hz/150Hz) 40%(for each tone)
Adjustable Range Full Range / 0.1% step
Modulator
Mod Stability ±0.1% at the operating system
SDM Stability ±0.8% at the operating system
DDM Stability ±0.2% at the operating system
Tolerance ±0.01% at the operating system

1-1
1. Specification

Operating Mode AND, OR (selectable)

System change Time 1sec Max. (refer to ICAO Annex 10 CAT Ⅲ-c)

Configuration of Monitor System Integral(BITE), Near Field and Far Field

DDM (COU:0±0.009DDM, Width:±0.025 at 0.175DDM)


SDM(±4% at 80%)
Monitoring MOD(±2% at 40%)
Frequency Difference
Monitoring ITEM
DC voltage and Main power
(hot & cool standby monitoring)
RF level(±20% at setting value)
Center Line Alarm
Displacement Sensitivity Alarm
Each Monitor Ant. Operation Alarm

Alarm Time Delay 0.5sec to 10sec, Adjustable step is 0.1sec.

-5dBm to -35dBm, In here output power is fixed by AGC circuit in MON


Receiver Dynamic Range
unit that It is processed by DSP device.

1-2
1. Specification

OS : Base on Windows XP
PC LMMS
CPU : Core 2 duo
(Desk Top)
RAM: 2G, HDD: 250GB or higher

OS : Base on Windows XP
Control Function PC RMMS
CPU : Core 2 duo
(Note Book)
RAM : 2G, HDD: 120GB or higher

GUI Program Base on Windows XP


Communication Line RS-232, RS-485, Ethernet, ADSL/SDSL
Input AC 110V to 220V±10%, 50Hz±5% single phase, SMPS type
Output Power 28V, DC
Max. handling current 40A Max
Type Dual redundant power(refer to system block diagram)

Power Supply Input DC +28V from AC/DC


Output Power +6V, ±15, +28V
Battery capacity 5 hour(When the full system turn on)
Battery type dry type and not need any maintenance
EMC/EMI Compliant to MIL Std-461C

1-3
2. Composition

GP system consists of 6 subsystems.,

UIS SCS SAS PSS ADS ANS


User Signal Signal Power Antenna Antenna
Interface Generation Modulation Supply Distribution Subsystem
Subsystem & Control & Amplifier Subsystem & Combine
Subsystem Subsystem Subsystem

CSP SYN MPA PSU ADU M-Array


ANT
RCMU AGU SPU PDU CMU (3EA)

RMU DETs

Interlock MON

LIU

1-4
3. Configuration : Rack

UIS
(user interface subsystem)

SCS
(signal generation & control
subsystem)

SAS
(signal modulation & amplifier
subsystem)

PSS
(power supply subsystem)

1-5
3. Configuration : UIS(user interface subsystem)

UIS
ANS

ADS SCS

PSS SAS

1-6
3. Configuration : SCS(signal generation & control subsystem)

ANS UIS

ADS SCS

PSS SAS

1-7
3. Configuration : SAS(signal modulation & amplifier subsystem)

ANS UIS

ADS SCS

PSS
SAS

1-8
3. Configuration : PSS(power supply subsystem) – Front Panel

ANS UIS

ADS SCS

SAS
PSS

1-9
3. Configuration : PSS(power supply subsystem) – Rear Panel

+28V +15V -15V +6V


COMM POWER 2 POWER 1 +28V +15V -15V +6V
1 4 1 4 1 4

2 3 2 3 2 3

INPUT 2 INPUT 1

1 1 +6V 1 1 +28V 1 1 +28V


GND GND GND GND 2 2 N.C 2 2 +6V 2 2 +6V GND GND GND GND
GND GND GND
3 3 +15V 3 3 +15V 3 3 +15V
4 4 -15V 4 4 -15V 4 4 -15V

DC 28+ GND +6V GND +15V GND -15V GND DC 28+ GND +6V GND +15V GND -15V GND

BATTERY BATTERY
DC+ GND DC+ GND
RS232 RS232
D-SUB D-SUB

V-Adj V-Adj

V-Adj V-Adj

AC INPUT AC INPUT
AC 110V/230V/, 50/60Hz AC 110V/230V/, 50/60Hz

AC L AC N FG AC L AC N FG

1-10
3. Configuration : ADS(antenna distribution & combine subsystem)

ANS UIS

ADS SCS

PSS SAS

1-11
3. Configuration : ANS(antenna subsystem)

ANS
UIS
Upper Antenna
ADS SCS

PSS SAS
Middle Antenna

Lower Antenna

1-12
1. Unit Explanation

Unit Explanation

• Control of ILS full system


• Control through interface of external, user and internal modules
CSP
• Control and supervision of output by AGU & SPU
• Management of each alarm and alert by MON & SIU

• RF signal generation and provide to MPA


SYN • Local signal generation and provide to CMU detector
• Provide of RF(COS, CLR) signal monitor port in rear panel

• Audio signal(90/150Hz) generation and provide to MPA


AGU
• Provide of audio signal(COS CSB/SBO, CLR CSB) monitor port in front panel

• Converting analog signal from each detector to digital signal


MON
• Digital signal analysis by FPGA and transmit to CSP

• LIU play a Hub for ethernet communication between modules


LIU
• All internal ethernet communication is connected through LIU

• Control and monitor of MPA through CSP


SPU
• Control factor are output and phase and monitor factor are phase, output, temperature and so on

2-1
1. Unit Explanation

Unit Explanation

• Provide of CL/CS/CLR RF test port


• Envelope detection of CL & CS signal
STBY DET
• Can set up same condition with ground by control of SBO gain and phase
• Inserted 100W term and directional coupler because of directly receive of MPA output

• Provide of COU CSB/SBO and CLR CSB test port


FWD DET • Envelope detect at DET diode after amplifying of signal from output divider port
• Detect signal is sent to MON Board > A/D conversion > 90Hz/150Hz/1020 signal detection

• Provide of COU CSB/SBO and CLR CSB test port


RVS DET • Envelope detect at DET diode after amplifying of signal from output directional coupler port
• Detect signal is sent to MON Board > A/D conversion > DC level detection

• Provide of CL, CS and CLR test port


CMU DET
• Detect signal is sent to MON Board

• Provide of NFM test port


NFM DET • Envelope detect at DET diode after amplifying of signal from near field monitor antenna
• Detect signal is sent to MON Board > A/D conversion > 90Hz/150Hz signal detection

2-2
1. Unit Explanation

Unit Explanation

• Amplifier after receive RF signal(from SYN) and audio signal(from AGU)


Fucntion
• Amplitude and phase locking

• CSB : receive 0dBm(from SNN)  amplify 37dBm(5W)


COS_RF
• SBO : receive 0dBm(from SYN)  amplify 23dBm(200mW)
MPA

CLR_RF • CSB : receive 0dBm(from SNN)  amplify 28dBm(600mW)

• CSB, SBO modulation signal generate after composite RF signal and audio signal
Modulation
• Control of gain and phase change

• Receiving of equipment signal and output to ANT


ADU • Input port : 3 port > COS CSB, COS SBO and CLR CSB
• Output port : 3port > Upper ANT, Middle ANT and Low ANT
ADS
• Receiving of ANT signal and output to equipment
CMU • Input port : 3port > Upper ANT, Middle ANT and Low ANT
• Output port : 3 port > CL, CS and CLR

2-3
1. Unit Explanation

ADU
(Antenna Distribution Unit)

Gain & Phase Relationship

2-4
1. Unit Explanation

CMU
(Combining & Monitoring Unit)

Adjustment Range

Phase
MIN Standard MAX
Error

Low & Upper


CL Adj. -1.5dB 0dB 1.5dB +/- 1°
Ant

CL & Middle
CS Adj. -2.5dB 0dB 2.5dB +/- 1°
Ant

Upper Ant
Clearance - - - -
Output

2-5
2. System Block Diagram

2-6
3. Signal Flow

2-7
4. Test Point & Output

2-8

S-ar putea să vă placă și