IN ENGINE ROOM
ALARMS CONTROL PANEL
21 25
13 17
5 9
1 22 26
14 18
2 6 10
23 27
3 7 11 15 19
24 28
4 8 12 16 20
29 33 37 41 45 49 53 57 61 65
30 34 38 42 46 50 54 58
31 35 62
39 43 66
47 51
32 36 55 59
40 44 63
48 52 67
56 60
64 68
FIRE ALARM ZONE
HIGH LEVEL HIGH LEVEL
LEVEL SWITCH
9 10
5 6 7 8
1
NM 76-84 AL 92 C
F.W. OUT COMMON
2
NM 76-84 AL 97 C
TO TEMP SWITCH
OIL PRESS AUT.START
STANDBY PUMP
PRESSURE SWITCH
NM 27-30 START 21 bar
1
2
3
4
5
THRUST BEARING TEMP HIGH
OIL PRESS AUT.START
LUB.OIL TEMP HIGH
EXH.GAS TEMP HIGH
EXH.GAS DETECTOR
TEMP SWITCH
GEAR LUB. OIL TEMP HIGH
OIL PRESS AUT.START
STANDBY PUMP
AIR TO EM’CY STOP
WATER LEVEL
TO PRESS SWITCH
PRESS SWITCH
PRESS SWITCH
F.W
AUX. CONTROL PANEL
FIRE ALARM BOTTOM
SMOKE DETECTOR
ALARM SYSTEM
PRESSURE GAUGE
PRESSURE
SWITCH
PIPING
BELL
• 1. EARTH FAULT ALARM SYSTEM
• 2. TEST ALARM SYSTEM
• 3. SUPPLY 1 FAULT
• 4. SUPPLY 2 FAULT
• 5. LUB OIL TEMP HIGH
• 6. LUB OIL PRESS LOW
• 7. LUB OIL PRESS M/E AUT.SHUT
• 8. LUB OIL PRESS M/E SHUT DOWN
• 9. LUB OIL DIFF PRESS HIGH
• 10. M/E S.W TEMP HIGH
• 11. M/E S.W PRESS LOW
• 12. M/E F.W TEMP SHUT DOWN
• 13. M/E F.O PRESS LOW
• 14. EXH. TEMP HIGH
• 15.M/E AIR PRESS MANEUV LOW
• 16. M/E OVERSPEED STOP
• 17. OVERSPEED STOP FAILURE
• 18. UPPER BEARING TEMP HIGH
• 19. THRUST BEARING TEMP HIGH
• 20. LUB OIL GEAR TEMP HIGH
• 21. LUB OIL PRESS GEAR LOW
• 22. LOW PRESS GEAR EX. LOW
• 23. SERV OIL GEAR PRESS LOW
• 24. GEAR SERV LOW PRESS AUT START
• 25. STERNTUBE OIL PUMP LOW
• 26. POWER FAIL EMERGENCY STOP
• 27. POWER FAIL CONTROLREMOTE
• 29. M/E EXPENTION TANK LOW
• 30. BOILER EXPENTION TANK LOW
• 31. F.O SERVICETANK H/L
• 32. SETTLE TANK H/L
• 34. F.O ALARM HIGH
• 35. WASTE OIL TANK HIGH
• 36. DRAIN OIL TANK HIGH
• 37. BILGE WATER TANK HIGH
• 38. SEWAGE LEVER HIGH
• 39. BILGE WATER M/E HIGH
• 40. BILGE WATER AUX. ENG HIGH
• 41. OIL BILGE DISHARGE
• 42. LUB OIL TANK M/E LOW
• 43. LOB OIL TANK AUX ENG LOW
• 44. LUB OIL TANK LOW
• 45. FAILURE AUX 1
• 48. FUEL OIL SEPERATOP WATOR SEAL
• 49. OVERLOAD / REVER POWER ALT 1
• 51. OVERLOAD / REVER POWER ALT 3
• 52. FREEZER ROOM HELP
• 53. BILGE WATER FOC.LE
• 54. FREEZER ROOM TEMP ALARM
• 57. FIRE ALARM FAULT
• 58. FIRE ALARM ZONE 1
• 59. FIRE ALARM ZONE 2
• 60. FIRE ALARM ZONE 3
• 61. FIRE ALARM ZONE 4
• 62. FIRE ALARM ZONE 5
• 63. FIRE ALARM ZONE 6
• 64. FIRE ALARM ZONE 7
• 65. FIRE ALARM ZONE 8
• 66. FIRE ALARM ZONE 9
• 67. FIRE ALARM ZONE 10
• 68. START EM’CY DIESEL
LUB OIL STANDBY PUMP
ENGINE RPM.
TURBO CHARGER
TO PRESS SWITCH
L.O PUMP
TO PRESS SWITCH
FILTER PRESS SWITCH
S.W PUMP
BILGE ALARM