CALIBRATION DE CAPTEURS

Auteur Aomar BOUMRAR


Unit Supervisor DML
Juillet 2011
DRAWWORK
CALIBRATION ADLOC

Drum diameter : 0.787m

Cable diameter :0.0381m

Number of lines between bloks :10 u

Number of grooves on drun:36 u

Complete cable layer(s) drun :0 u

Coeff.current:1.000 u

Juillet 2011
Calibration WOH
CALIBRATION ADLOC

4mA --------- 0 bar 0bar ------------ 0t


8,98mA --------- 15,6 bar 15,6bar --------- 102t

9,18m A ---------- 16,21 bar 16,21bar----------- 110t

12,80mA ---------- 27,5 bar 27,5 bar ---------- 180t

Juillet 2011
Calibration WOH
Calibration Points Manufacture

signal (mA) Pressure Values (bar)


4 0
20 50

Equivalent Pressure For a Signal Values


Input Signal (mA) Result Pressure (bar)
9,18 16,1875

Juillet 2011
Calibration SPP

CALIBRATION ADLOC

4mA --------- 0psi.

15,90mA------- 4470 psi. Néant

Juillet 2011
Calibration
TORQ

CALIBRATION ADLOC

0mv-------- 0A. 0A--------- lb*f

1,757mv-------450A. 5mA---------26500lb*f

Juillet 2011
Calibration PIT Level

CALIBRATION ADLOC

4mA--------0.25m Cross section :14.68m2

20mA-------2.5m Dead volume :100L

Juillet 2011
Calibration PIT Level
Trip Tank

CALIBRATION ADLOC

4mA--------0.25m Cross section :2m2

20mA-------5m Dead volume :100L

Juillet 2011
Calibration Mw

CALIBRATION ADLOC

4mA--------1 g/cm3

10.399mA-------1.32g/cm3

Juillet 2011
Calibration T°

CALIBRATION ADLOC

4mA-------- 0 deg C

20mA------- 200 deg C

Juillet 2011
Calibration H2S

CALIBRATION ADLOC

4mA--------0ppm

20mA-------100ppm

Juillet 2011
Calibration Pump

CALIBRATION ADLOC

Efficiency :0.94

Stroke displacement :14.02

Cut off :5l/min

Number of pulses per stroke :1 u

Gear factor and p/stk:1 u

Juillet 2011
Calibration RPM

CALIBRATION ADLOC
number of pulse per revolution=4 unit

gear factor and p/str =1 unit

Juillet 2011