Sunteți pe pagina 1din 49

ALCATEL-LUCENT 9500 MPR LONG-HAUL R5.

1
Wireless Transmission Installation & Commissioning

May, 2014

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
ALCATEL-LUCENT 9500 MPR
UNIQUE, SIMPLIFIED, END-TO-END PORTFOLIO

Metro cell sites Macro cell last mile site Microwave Hub Site Microwave/Fiber Hub Site
(9500 MPR-s) (9500 MPR) (9500 MPR) (9500 MPR)
Common MPTs: Split-
• Full outdoor mount

• Split-mount

Full indoor

MSS-8
MSS-1 MSS-4

Single Management Platform

INNOVATIVE END-TO-END PRODUCT FAMILY EFFICIENTLY ADDRESSING ALL SITES & APPLICATIONS

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
ALCATEL-LUCENT 9500 MPR LONG-HAUL
A SIMPLE EXTENSION OF THE 9500 END-TO-END STRATEGY
ETSI
MPT-HC MPT-HL

SAME:
• architecture
• software OS
• network and services management
• compact indoor networking options

COMPACT INDOOR NETWORKING OPTIONS


MSS-1 (0.5 RU)

MSS-4 (1 RU)

MSS-8 (2 RU)

UNIQUE, SIMPLIFIED, END-TO-END PORTFOLIO

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9500 MPR MICROWAVE SERVICES SWITCH (MSS)
COMPACT AND FULLY-FEATURED INDOOR UNITS

MSS-1 (0.5 RU) MSS-4 (1 RU) MSS-8 (2 RU)

FEATURES MSS-1 MSS-4 MSS-8


• Fixed • Modular: • Modular: 8 slots
• No slots • 2 core slots (1+1), 2 interface slots • 2 core slots (1+1), 6 interface slots
CHASSIS • 16 Gbps • 16 Gbps • 16 Gbps
• Operating temp: 40C to +65C • Operating temp: 40C to +65C • Operating temp: 40C to +65C
• 16 E1/DS1, 4x 10/100/1000 RJ-45, • Up to 64 E1/DS1, 4 DS3, 4 STM1/OC3, • Up to 192 E1/DS1, 12 DS3, 2 E3,
2x SFP 2 E3, 22 GE 12 STM1/OC3, 54 GE
INTERFACES • Console, sync-in & sync-out, ToD, • Console, sync-in & sync-out, ToD, • Console, sync-in & sync-out, ToD,
management, alarm management, alarm management, alarm

• TDM/PDH, SONET/SDH • TDM/PDH, SONET/SDH • TDM/PDH, SONET/SDH


SERVICES • MEF compliant E-Line, E-Tree, E-LAN • MEF compliant E-Line, E-Tree, E-LAN • MEF compliant E-Line, E-Tree, E-LAN

• ITU-T G.8032 • ITU-T G.8032 • ITU-T G.8032


NETWORKING • Multichannel Ethernet LAG • Multichannel Ethernet LAG • Multichannel Ethernet LAG
• SONET/SDH • SONET/SDH • SONET/SDH
• Dual feeds: -48/-60V DC, or optional • Dual feeds: -48/-60V DC, or optional
POWER • Dual feeds: +/-24V DC to +/- 48V
integrated +24V DC integrated +24V DC

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9500MPR TRAFFIC OPTIMIZATION
TDM TRAFFIC SDH CHANNELIZED
E1s are transported without STM-1 channelized is
being mapped on the SDH terminated and active E1 are
layer. MSS-8 carried.

PACKET TRAFFIC SDH TRANSPARENT


No need for packet and TDM STM-1 transparent is also
switch – packet only supported

MSS: MW INDOOR UNIT WITH INTEGRATED SWITCH & ADM


LESS EQUIPMENT – LESS SPACE - LESS SPARES
LESS POWER – SIMPLIFIED OPERATIONS
ANY TRAFFIC MIX
7

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
INTRODUCING THE NEW 9500 MPR LONG-HAUL SYSTEM

TOP RACK UNIT (TRU)


FANS • Power distribution
RECEIVER FILTERS
TRANSMIT FILTERS

NETWORKING
TRANSCEIVERS • Compact MSS indoor unit
• 10 per subrack • Extra space for:
• 20 per rack • MSS for high port density add/drop
• IP/MPLS options
FANS • Nodal and/or repeater configurations
• Up to 20 directions:
• Repeater up to 10 directions
• Nodal up to 4 directions
• 10G microwave networking ready

ENABLING OPERATORS TO INCREASE MICROWAVE CAPACITY AND REDUCE NETWORK TCO

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
NEW 9500 MPR LONG-HAUL MPT-HL
EFFICIENTLY ADDRESSING THE NEEDS OF LONG-HAUL NETWORKS

9500 MPR LONG-HAUL MPT-HL


TRANSCEIVER SPECIFICATIONS

Frequencies supported 4 to 13 GHz

Bandwidth 14 to 56 MHz

XPIC module integrated

Second receiver port for space diversity integrated

Increased system gain 4 dB

Adaptive Modulation 4 to 1024 QAM

HIGHEST DENSITY LONG HAUL SYSTEM IN THE MARKET TODAY

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
MPT-HL CONNECTION TO MSS
RX Div
CONNECTION IS SFP BASED

RX

CORE BOARD/ MSS1


CONFIGURATIONS 1+1 or 2+0

TX

EAS v2 BOARD
CONFIGURATIONS N+0 or LAG
MPT HL

10

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
WHY EVOLVE TO PACKET LONG-HAUL?
MORE CAPACITY PER CHANNEL
TDM BASED PACKET BASED
INCREASE
CAPABILITY MORE CAPACITY
FACTOR
More efficient
transceivers
28 MHz to 56 MHz wide channels 2X
Generic Framing Procedure (GFP)
Removal of SDH frame
versus direct Ethernet
1.1X
Higher modulation
rates
Moving from 128 to 1024 QAM 1.37X
Up to 3X
Packet Compression
(1.5X – 2X based LTE profile)
1.6X

Multichannel radio LAG No dedicated protection channel 1.25

> 6X
STM1 BASED GE BASED

>6X CAPACITY INCREASE, USE IDLE CAPACITY, AND STATISTICAL MULTIPLEXING

11

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
POWER CONSUMPTIONS BENCHMARKING
ADM DECOMMISSIONING – PACKET TRANSPORT

9500 MPR
4 CHANNELS
1024 QAM AM
CONFIGURATION 4 CHANNELS
28 MHz
+ 2 PDH BOARD
880Mb/s
Payload

9600 LSY -185 Watt


4 CHANNELS+ ADM -32%

6 CHANNELS LSY + MSS -193 Watt


128 QAM FIXED / 28MHz -34%
840Mb/s Payload

12

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
ALCATEL-LUCENT 9500 MPR LONGHAUL
MPT-HL SYSTEM GAIN
SYSTEM GAIN FOR LONG HAUL SYSTEM IS LINKED TO
• RT PERFORMANCES
• BRANCHING LOSSES

RT 6 U 64 QAM 7 GHz 128 QAM 7 GHz 256 QAM


PERFORMANCES 40 MHz 28 MHz 28 MHz
9500 MPR HL 111 dB 108 dB 102 dB
9600 LSY 107 dB 103,5 =
DIFFERENCE 4 dB 4,5 dB

9500 MPR HL: BEST IN CLASS ON THE MARKET !


INCLUDING BRANCHING : 4 dB BETTER THAN BEST COMPETITOR
13

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
DIVERSITY RECEIVER WITH DIGITAL COMBINER

RPS
• Traditional switching
• ALU Enhanced RPS selects frame by frame based on the signal quality

IF COMBINER
• Combination performed on IF domain

DIGITAL COMBINER
• Flexibility and performance improvement:
• Automatic alignment
• Recovery of up to 200m delay between main and diversity
• Better performance in the event of simultaneous impairments on
both channels
14

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
PACKET MICROWAVE FOR THE LONGHAUL
MPT-HL HIGH CAPACITY H-QAM SUPPORT

1024 QAM
ADAPTIVE MODULATION AWARE MULTICHANNEL

MPT-HL

128 QAM @ 28 MHz: 163 Mbit/sec

256 QAM @ 28 MHz: 185 Mbit/sec +14%

512 QAM @ 28 MHz: 208 Mbit/sec +12%

1024 QAM @ 28MHz: 231 Mbit/sec +11%


SUPPORT FOR 1024 QAM ADAPTIVE MODULATION & MULTICHANNEL INTELLIGENCE

15

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
WHY EVOLVE TO PACKET LONG-HAUL?
MORE CAPACITY PER FOOTPRINT - LOWER NETWORK TCO

2 DIRECTIONS, 2 DIRECTIONS,
1.26 Gbps each 10 Gbps each

LOWER NETWORK TCO

TDM BASED PACKET BASED


(9:1 protection) (10:0 protection)

8X CAPACITY IN 1/3 THE FOOTPRINT

16

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
SEAMLESS EVOLUTION OF INSTALLED BASE

FOR INSTALLED BASE:


• KEEP RACK
• KEEP ANTENNAS
• KEEP BRANCHING

New packet
indoor unit
UPGRADE/REPLACE:
• TRANSCEIVERS
• PACKET INDOOR UNIT New
transceivers

WELL POSITIONED TO EVOLVE LONG-HAUL INSTALLED BASE TO PACKET

17

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
RF EXPERTISE
LEVERAGE AND EXPAND RF TOOLKIT
SIGNATURE OPTIMIZED SYSTEM GAIN EXCELLENCE

Increase resistance to selective fading Reduce antenna or increase availability

RF TOOLKIT
SPACE DIVERSITY LINK HIGH MODULATION SCHEME

Baseband combiner in second receiver Increase capacity and link availability

18

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
SITE SURVEY
• Pre-conditions under the customer responsibility for standard Installation :
The site must be accessible by road with full access and a contact person. Sites location on a map, physical address, GPS coordinates
Sites description (including indoor & outdoor images of the site) + Images of line of sight with the potential position of the antenna(s)
MW equipments types and HW configuration. Check on new load capacity on tower.

• Check of access condition & civil work


Site address, location map, physical access, Technical room location, Elevator/staircase availability, Contact person
Rack, DC Power, Pole, Pylon Air Conditioning, Fire alarms, safety system (if any)
• Indoor Installation details:
Technical room configuration, location of equipment to be installed
Indoor grounding points conformity and check of lightning
DC Power supply configuration and parameters (Primary and secondary, charger); DC breaker available
Indoor cable ducts configuration, Wall/Roof feed-thru availability
DDF configuration
• Outdoor installation detail :
Description of aerial installation (pylon/roof/water tower/others), with Height & Available space on tower for new antenna positioning.
Outdoor grounding points conformity and check of lightning
Availability of cable ducts & difficulty to install cable/feeder, type & Qty of clamps according to the cable ducts / tower attachments
Description of co-located outdoor radio equipments or antennas, with indication of the radio beam(s) direction and frequency
Estimation of global cables length (indoor and indoor-outdoor)
Elaboration of preventive plan for risks, reporting & images with eventual blocking points

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
LINK BUDGET & DIMENSIONING
• Link configuration and propagation calculations:

Link Availability
Fading
Margins

1900

1800

1700

1600

1500

1400

1300

1200

1100

1000

900

800

700

600

500

400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70. 1

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
INSTALLATION
• Pre-conditions under the customer responsibility for standard Installation :
The physical site must be accessible by road with full access and a contact person
The customer must deliver a site preparation report with information on configuration & preparation (energy, cables duct, digital
distribution frame, existing microwave installations, …). This apply only if Alcatel-Lucent is not in charge of site preparation,
Check on new load capacity on tower. Alcatel-Lucent personnel must be provided with a safe work environment

• Indoor equipment installation :


Unpacking and control of the shipped equipment
Mounting & fixing of indoor racks & cabinets into position. Assembling Indoor board(s). Intra & inter rack/cabinet/equipment cabling
Connection to secondary 48v power supply & the electrical ground
Connection of tributaries, NMS access and house keeping connections to the Digital Distribution Frame (DDF)

• Installation in case of split mount or full indoor equipment :


Installation of the antenna, the pole mounting & the ODU on the mast / pylon for the split mount
Installation of the Indoor-Outdoor cable or the elliptic wave guide in the cable duct with connectors at each termination
Grounding of the antenna, ODU, IDU-ODU cable and the wave guide
Installation of the wave guide pressurisation device for full indoor
• Common :
Pre-positioning of the antenna (with compass and/or binoculars)
Identification of both Indoor and Outdoor cables with labels & Update of the installation document with pictures detailing
Waterproofing conformity & Site cleaning to remove all the waste produced during installation of the microwave

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
COMMISSIONING
• Pre-conditions under the customer responsibility that must be fulfilled prior to the delivery.
Alcatel-Lucent personnel must be provided with a safe work environment and authorised access to the respective site,
Information on hardware configuration, Tx/Rx frequency, shifter, Data rate, modulation, Tx/Rx power value, Equipment supervision, ….
The customer must provide a site contact person for commissioning topics (frequency planning, RF perturbations,…).
Availability of a preventive plan for risks.

• List of basic operations included in Commissioning service :


Control of equipment installation, antenna type, size and installation, of indoor-outdoor and cable(s)/feeder(s) grounding
Control of tributary, auxiliary channels and alarms cabling in the DDF,
Measure of wave guide VSWR (Long haul only),
Check of 48v power supply and Equipment warming up,
Check of software releases & equipment serial numbers,
Check of local & remote terminals supervision, of the terminal configuration (Transmission parameters, Alarms thresholds),
Check Antennas pointing (2 sites) and end to end transmission,
Test of RF channels switching, of local and remote loops,
Test of transmission & 48V power supply alarms
Check of Tx/Rx power measure, Main-Diversity in XPIC configuration (SDH Long Haul products only),
Measure of the receiver BER characteristic,
Fulfilment of the Control, measures sheet and the acceptance certificate then delivery of the documentation to Alcatel-Lucent,
Update of the site installation document with pictures giving detail on antennas branching, IDU-ODU cable mounting and grounding,
cables labelling, tributaries cabling, miscellaneous inter-units cabling, etc...

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
PRE-CONDITION BEFORE SWAP INTERVENTION

The customer must deliver all the necessary information on hardware & software configuration.

• Save / Collect local equipment configurations, connection, routing tables in each station.
Physical Hardware Configuration
Make a list of the Data rate, the modulation, the Tx/Rx frequency, shifter, Tx power value, estimated Rx power value,
Make an inventory of Alarms on Equipment
Check that the link is supervised by the operation center
Make a Quality & Performance monitoring..

• Network Design / Link Budget has to be available


• Depending of the project and if necessary make a Return Los measurement
• Check Spares of Filters availability
• Make a Site survey and a visual check before migration
• Check the real usage of each breaker before initiating the system upgrading has to be done
• The peoples in charge of the Installation & Commissioning must have a good Knowledge,
competencies of 9600 LSY & 9500 MPR Products

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
SUBRACK CONNECTIONS
DATA & RPS

Data connections
RPS connections

* Refer to user manual for cables references


26

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
SUBRACK CONNECTIONS
XPIC

XPIC connection can be


established in one of these
configurations :

1-Intra-rack connections
between two RTs on the same
sub-rack (in red)
2-Intra-rack connections
between two RTs on different
sub-racks (in blue)
3-Inter-rack connections
between two RTs on different
rack (in purple)

* Refer to user manual for cables references


27

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
SUBRACK CONNECTIONS
FAN Management
Power connections
FAN Management connections

* Refer to user manual for cables references


28

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
SUBRACK CONNECTIONS
FAN Management

* Please refer to user manual for cables references


29

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
TRU UPGRADE
New TRU if needed

* Please refer to user manual for more informations


31

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9600 LSY UPGRADE

STEP 1
INSTALL THE ADAPTER KIT
To adapte the MPT-HL to the LSY
Subrack at the mechanical
dimension

33

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9600 LSY UPGRADE

INSTALLED BASE
GEth INSERT MSS
UPGRADE
STEP 2
KEEP STM-1 & ADD PACKET
STM-1
Add new transceivers packet ready
Up to 300Mb/s per TX

STEP 3
MOVE STM-1 TO PACKET
Replace existing transceivers
Up to 300Mb/s per TX
INSERT MPT-HL
34

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9600 LH UPGRADE

MPR LH SYSTEM CAN EASILY UPGRADE 9600 LH

• DEDICATED RT SUBRACK
• REMOVE ONLY OLD ELECTRONIC
• KEEP ETSI RACK, WAVEGUIDE , BRANCHING
• KEEP FILTERS
• KEEP ANTENNA AND INSTALLATION
MATERIAL
• SAVE CAPEX AND OPEX
• MIGRATION TO PACKET, INCREASING
CAPACITY

36

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9600 LH UPGRADE
Mechanical Subrack

Peel one end of 15 mn Insert the wire inside Pull-up the two lateral Pull down the connector
the connector orange levers

37

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9600 LH UPGRADE
MPR LH SYSTEM CAN EASILY UPGRADE 9600 LH
2 Channels 4 Channels
Scenario Scenario

38

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9500 MPR ADVANCED PACKET COMPRESSION
PACKET THROUGHPUT BOOSTER

PACKET COMPRESSION
AND

XX
MULTICHANNEL
BEFORE TRANSMISSION
• IFG/Preamble are
suppressed
• Ethernet/MPLS/IP headers
are compressed

X X
INCREASE EACH CHANNELS THROUGHPUT BY AS MUCH AS 300%

40

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9500MPR MULTISERVICE PACKET RING SOLUTION
DOUBLING THE CAPACITY

•Same physical packet ring can simultaneously


9500MPR protect mixed TDM and Ethernet traffic
•Clock wise and anticlockwise
•In case of failure, the traffic is re-routed: high
9500MPR
priority TDM & Ethernet are transmitted and best
effort traffic is kept if capacity is available

9500MPR

9500 MPR DELIVERS MAXIMUM RESILIENCY ALLOWING DOUBLE CAPACITY TRANSPORT AS


“NORMAL RULE”

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
9500 MPR MULTICHANNEL
SCALABILITY, RELIABILITY, ALL SERVICES, ADAPTIVE MODULATION AWARE
One logical pipe, total capacity
Multichannel distributing flow available to all services
contents over 4 channels
PDH ETHERNET FLOWS

MULTICHANNEL
SDH

Multichannel 4+0
microwave link

RELIABLY SCALE ALL SERVICES WITH ONE TECHNOLOGY WITHOUT DEDICATED PROTECTION

42

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
A NEW PARADIGM IN NETWORK DESIGN
DIFFERENT AVAILABILITY FOR DIFFERENT SERVICE

o NO MORE A SINGLE AVAILABILITY VALUE


o AVAILABILITY ACCORDING TO QoS

capacity o BETTER PERFORMANCES vs N+1


3+1
o MULTICHANNEL
LAG 4 ch o HIGH MODULATION SCHEME
availability
o ADAPTIVE MODULATION
o MORE CAPACITY vs SAME AVAILABILITY
o MORE AVAILABILITY vs SAME CAPACITY

NEW MODEL TO PERFORM NETWORK DESIGN

43

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
USEFUL LINKS

• WT Portal : http://all.alcatel-lucent.com/wps/portal/businessgroups/carrier/wtp
• WT Forum : http://forum.app.alcatel-lucent.com/
• LKDI Portal : https://softwarekeys.alcatellucent.com/flexclientws/home.jsp
• OLCS : https://support.alcatel-lucent.com/portal/olcsHome.do
(User Manual, Release note, Software, etc.)

• FTP-WT Server : ftp://ftp-wtd.alcatel.com/PSC/9500MPR/


• VIDEO TRAINING : https://training.alcatel-lucent.com/Saba/Web/Main
(Not Updated)
TER60006W -> 9500 MPR R3.3 SW Installation and Commissioning
TWT18014W -> 9500 MPR Hardware Installation

45

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
AGENDA
1-PRODUCT PRESENTATION
2-SERVICES DESCRIPTION
A- SITE SURVEY
B- LINK BUDGET & DIMENSIONING
C- INSTALLATION
D- COMMISSIONING
E- PRE-CONDITION BEFORE SWAP INTERVENTION
3-DEPLOYMENT SCENARIOS
A- New deployment - Subrack connections
B- TRU Upgrade
C- 9600 LSY Upgrade
D- 9600 LH Upgrade

4- FEATURES HIGHLIGHT
5- USEFUL LINKS
6- HANDS-ON EXPERIENCE

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
HANDS-ON EXPERIENCE
Exercices

1- Subrack Creation
2- 9500 MPT-HL Creation Slot 3 & 4
3- EAS v2 Configuration Slot 7.5 & 7.6
3- Radio Configuration
- 28 Mhz / 512 QAM
- Shifter Value = 252.04
- Frequency CH1 : Site A = 6286290 ; Site B = 6034250
- Frequency CH2 : Site B = 6256540 ; Site B = 6004500

4- Lag Configuration
5- Cross Connection Configuration
6- Vlan declaration
7- Packet Booster

47

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION
NEW 9500 MPR LONG-HAUL
EFFICIENTLY ADDRESSING THE NEEDS OF LONG-HAUL NETWORKS
9500 MPR
FEATURE HIGHLIGHTS
(MPT-HL ETSI)
• 4 GHz to 13 GHz.
• 14 to 56 MHz channel widths
• Adjacent channel support
RADIO
• Integrated XPIC
• Optional second receiver for space diversity - frequency, space, RF band
• Adaptive modulation - 4 to 1024 QAM, ATPC, RTPC
• Mixed repeater and nodal configurations
• ITU-T G.8032v2 support
NETWORKING • Up to 20 directions:
• Repeater up to 10 directions
• Nodal up to 4 directions
• Wide choice of ETSI racks:
• 1300 mm ETSI rack suitable for outdoor cabinet
• Fully protected configurations with no single point of failure:
PHYSICAL
• Indoor MSS cards, transceivers, transceivers to sub-rack connections , fans
• Optimized thermal configuration
• Low power consumption

MANAGEMENT • Single rack managed as a single network element

49

COPYRIGHT © 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.


ALCATEL-LUCENT — INTERNAL PROPRIETARY — USE PURSUANT TO COMPANY INSTRUCTION

S-ar putea să vă placă și