Documente Academic
Documente Profesional
Documente Cultură
• Network Diagrams
Representation of Sites • Analysis Functions
Load Flow and Short Circuit
Enhancements
• Analysis Functions Network Reduction
Protection Performance Audit RMS/EMT Simulation
Quasi Dynamic Simulation Optimisation Methods
Project Combination
Transmission
Network
Distribution
Network
Combined: Transmission
& Distribution Network
DIgSILENT GmbH - PowerFactory 2017 4
Handling and Data Management
Snapshot Export
• Application Cases
Outage Planning
• Definition
– Convenient way to create / edit / delete
planned outages
– Support of recurrent outages
– Action Recorder to facilitate definition of
Remedial Actions
• Operation
– Apply single or multiple planned outages
– Reset all planned outages
Representation of Sites
– New symbols for site representation (schematic/GPS diagrams)
Protection Audit
– Validation Tool for Protection Settings & Configuration:
distance, overcurrent and differential relays
– Support of Events
• Typical Application
– Day/Month/Year simulations
– E.g. modelling of a battery
with charging/discharging logic
Add-On Modules
• User definable Add-On Module
– Add-On Module =
Calculation-Script +
Predefined Result Variables +
Default Result Box Configuration +
Default Colouring Modes
– Result Variables:
• Support integer, double, string, arrays, and
object
• Support variable per connection/ per phase
zl3
4-Winding Transformer zi
zj
LV3
HV
zh zl2 LV2
zi
– Supports all calculation functions ym z j
zl1
–
LV1
Winding-connections: Y, YN, D, Z, ZN
– Autotransformer supported
– Impedance data input:
complete (winding to winding), simplified (per winding)
Harmonic Filter
Output Window
– Icons and colours to visualise message categories (error, warning, info,….)
Load Flow
– Improved convergence behaviour
– Active/Reactive power limits:
adjustable per model
– Support unbalanced feeder load scaling
– DC Load Flow:
Support automatic tap change for phase
shifting transformers
Short Circuit
– Performance enhancements
– Option to skip transient calculation
– IEC60909 2016 edition (later service
pack)
– PF2016:
Reduced network equivalent for load
– PF2017:
Short circuit equivalent – both balanced and
unbalanced representation
RMS/EMT Simulation
• Performance improvements
“initialisation”
– Reuse previous load flow results
for initial condition calculation; performance
benefit if executing multiple cases
• Simulation Scan
– New Fault Ride Through
Scan Module
– Any calculation variable
can be monitored
– User defined FRT characteristic
RMS/EMT Simulation
• IEC61400-27-1 interface
Optimisation Methods
(Distribution Network Tools)
Text Editor
– DPL/Python programming
– Remark:
Script languages support ~1500 methods
Questions…
DIgSILENT GmbH - PowerFactory 2017 25