Documente Academic
Documente Profesional
Documente Cultură
Rev. B
Maximize productivity
and machine efficiency
Rev. B
System integration for
optimized vehicle architecture
Rev. B
PVG 100 – Why ?
Rev. B
PVG 100 – What is it?
Rev. B
Introduction of PVG 100
Pre-Compensation Post-Compensation
Features • Compensator located in front of main • Compensator located after main spool
spool
• Compensator controls the P,
• Compensator controls individual P, determined by the highest load pressure
determined by the LS work-port (LSmax), and the pump pressure - P
pressure, and the compensated across the opening area of the main
pressure. spool.
• Compensator spring and LS opens the • Compensator spring and (LSmax) closes
compensation spool the compensation spool.
Simplified
Cetop
diagram
Rev. B
Flow Sharing Definition
Rev. B
Flow Sharing Definition Graph
70
Saturated Pump Flow
60
50
40
Flow
30
Pump Flow
20 Function 1
Function 1 Desired
Function 2
10
Function 2 Desired
0
0 1 2 3 4 5 6 7 8 9 10
Time
Rev. B
Flow Sharing Definition Schematic
Rev. B
Quiz? - PVG32 Pre-compensated
Rev. B
PVG 100 – Features
Hybrid solution
PVG32/100
Hybrid solution
PVG32/100/HIC
Rev. B
PVG 100 – Features
Rev. B
Work Sections
Rev. B
PVG 100 – Features
Rev. B
PVG 100 – Features
B
PVB100 PVB100 PVT100
1 PVPV 100-1 PVB100 PVTI100/32
PVBZ32 PVB32 PVS32
2
B B B
B B
P T
P T
A A A A A A
LX
LX
4
PVPV 100-2 PVTI100/32
3
PVB100
PVPV 100-2 PVB100 PVB100 PVT100 PVBZ32 PVB32 PVS32
PVB100
B
B B B P B B
P T
T
A A A
A A A T
T LX
LX
LX
Rev. B
Inlet Configurations
• Closed center inlet modules (PVPV)
– Pilot supply for electrical actuation
• Facility for pilot shut off
• Integrated priority valve (CF and Tank ports)
Rev. B
Work Section Configurations
• All sections have integrated pressure
compensator (post compensated)
• With/without Pilot Operated Checks
• With/without shock valves in A & B port
• BSP & SAE versions
• Mechanical, Hydraulic or Electrical Actuators
• Float Available – Also with P.O. Checks
• Spools
– Closed ported (cylinder)
– Open ported -- throttled (motor)
– 40, 65, 100, 130, 150 and 180 lpm Rev. B
PVG 100/32 Interface Module-PVTI
• BSP
• SAE
T
Must use PVG To Ls Pp
32 with T0
P
Rev. B
Endcover Configurations
Rev. B
Actuation modules
Ext. : 7328
Tech. Support Assistant
Louise Callesen
Casper Friis Henrik Thunø Mariann Ebbesen Finn Kaad Arne Egholm Steen Larsen
Ext.: +5254 Ext.: 3952 Ext.: +4319 Ext.: +4182 Ext.: +5327 Ext.: +2175
PVED
Customer order database PVG 100 PVG
PVE / EH Hybrid solutions PVE
Joystick PVG 32/120 Variant Configuration
Rev. B
PVG 100
New heights in flow-sharing
www.sauer-danfoss.com
Rev. B