1604112 Prof. Dr. A. A. GADHIKAR
The Vapor Compression Refrigeration Cycle involves four
components : Compressor, Condenser, Expansion valve/throttle
valve and Evaporator.
The refrigerant used does not leave the system, but is circulated
throughout the system alternately condensing and evaporating.
Ozone
3 Depletion 0
Level
Critical
4 252°F or 122°C
Temperature
Cylinder
5 Light Blue
Color Code
(COP)Refrigerator = Refrigeration Effect
Work Done by Compressor
Therefore,
(COP)R = h1 – h4
h2 - h1
Subcooling:-
After condensation process, the refrigerant is cooled below the
saturation temperature before expansion by throttling. This process is
known as subcooling.
Superheating :-
After evaporation process, the refrigerant is heated above the
saturation temperature before entering the compressor. This process is
known as superheating.