Sunteți pe pagina 1din 27

New LED Lighting Concept for 2’ x 4’

Drop Ceiling (S3)

Patent Pending
(PI 2010002400)
36W 4’ Fluorescent Tube
Emitting light in all direction

Need Reflector to Direct the Light down to


increase the Brightness
LED is emitting light at only certain
direction
So Why we need a LED light bulb in the
form of “fluorescent tube”?
And fit into the Florescent Fitting with
reflector

No reflection
from reflector
New Concept of LED Lighting without
Fitting with reflector
INSTALLATION INSTRUCTION

Step 1 : Step 2 :
Cut away 48mm of gypsum Cut gypsum board to half
board from side
Step 3 : Step 4 :
Place one piece of gypsum Place the Arrow Slim into
board into ceiling ceiling
Step 5 :
Step 6 :
Connect the Power Supply
Hide the Power Supply into
ceiling
Step 7 : Step 8 :
Place balance piece of Test the fixtures
gypsum board into ceiling
For new Ceiling safe cost on the fitting

For Existing fluorescent fitting just replace


with standard 2’x4’ ceiling board
The metal from old fluorescent fitting
can be recycle.
Installation by 3 inches Metal Trunking
suitable for Factory & Car Park
Installation on concrete, wooden
ceiling
Installation on Plaster Ceiling
Plaster ceiling and suspension rod
example
Installation by Suspension Rod
Suspension rod screw
on the nut inside the Power Supply
casing
Plastic trunking
covered the wire
Model
• 2 feet and 4 feet
• Supreme light
– Best quality of Light
• CRI >75 (cool white) >85 warm white
– Best for office, lobby, hotel etc
• Supreme save
– Best energy saving
• 15.5watt (include power supply loss) to replace 42watt
fluorescent T8 with equal brightness and coverage
– Best for Car Park, walk way with long operation hour
Brightness compare with Fluorescent
LUX measured from Vertical axis
90.00

80.00

70.00

60.00
LUX from 2.7m

50.00

40.00

30.00

20.00

10.00

0.00
-500 -400 -300 -200 -100 0 100 200 300 400 500

Distance along the Vertical axis (cm)


Energy consumption
• Total consumption include Power Supply with
85% efficiency :
– Supreme light 18watt
– Supreme save 15watt
• Power Consumption of 4 ft fluorescent 36W
include Magnetic low loss Ballast lost : 42W
• Energy saving :
– Supreme light = 24 Watt
– Supreme save = 27 watt
Standard Wiring
• One Power Supply to one unit
AC to DC 24V
AC240V
power supply

– AC to DC24V (constant voltage) power supply are


easily available in the market.
– For 4 feet model used minimum 20W of power supply
– For 2 feet model used minimum 10W of power supply
– Advisable to used Power Supply with Power Factor
Control (PFC) for large qty project
Centralize Power Supply Wiring
• To Safe Cost One Power Supply can powered
up few units of led light bar
AC to DC 24V
AC240V
power supply

– Rated power of power supply depend on number


of led light bar.
– Advisable to used Power Supply with PFC.
With LH-10 Dimmer Wiring
• The LED light bar can be dimmed using LH Dimmer.

Dimmer
AC to DC
AC240V

24V power
supply

Dimmer

1-10V Rotary 1-10V signal cable


Dimmer switch DC24V power cable
Dimmer

DC24V PWM power cable

AC24V power cable


With LH-10 Dimmer Wiring
• LH-10 Dimmer is a proprietary dimmer special for
LED Light Bar
• There are 3 output channels for one LH-10 dimmer.
• One channel can drive up to 5 units of 4’ model or 10
units of 2’ model.
• The 1-10V Rotary Dimmer Switch are easily available
in the market.
• LH-10 Dimmer can accept any 1-10V diming signal
from any type of Digital Dimmer
With LH-DMX Control Wiring
• The LED light bar can be control by using LH-DMX Controller

LH-DMX
AC to DC
AC240V

24V power
supply

LH-DMX

CAT-5 or DMX cable


DMX console DC24V power cable
LH-DMX

DC24V PWM power cable

AC24V power cable


With LH-Motion Control Wiring
• The LED light bar can be intelligent control by using LH-DMX
controller and motion sensor

LH-Motion
Motion Sensor

AC to DC
AC240V

24V power
supply
Motion sensor signal cable
LH-Motion

Motion Sensor DC24V power cable


DC24V PWM power cable

AC24V power cable


ROI
• Fluorescent 2x36watt + fitting =RM140
• LED bar + power supply = RM150 x 2 + 40 = RM 340
• Cost different = 340-140 = RM200
• Energy saving (supreme save)= 27x2 =54W
• 12 hours/day consumption safe= 54x 12= 648whr =
0.648 kWhour
• Saving/day = 0.648*0.4 =RM0.26
• Saving/year = 0.26x365=94.9
• ROI = 200/94.9 = 2.1 years
– (excluding maintenance cost for fluorescent)
• ROI for 24 hours operation = 1.05 years

S-ar putea să vă placă și