• After de-coupled motor trial, and also coupled fan trial the
coupling alignment need to be checked and re-established.
• The bearing housings are leveled with master level and the
fan shaft is lowered on the bearing liners. The NDE side
bearing pedestal is raised to maintain shaft level at DE
side. The bearing clearances are measured and bearing
housings are then boxed-up.
• The forced lube oil unit placement, lube oil cooler hydro
test, lube oil pipes joints welding, acid cleaning of piping
followed by oil flushing of pipelines are done in parallel
after establishing bearing housings placement.