Sunteți pe pagina 1din 20

GREATERNOIDA DISTRICT CENTER

AIM : Preparing the design for “Greater Noida District Centre”. Urban form and design is the outcome
of integration of the studies and process & expertise of many related disciplines i.e. Art, Architecture
Landscaping, Social Sciences, Economics, Planning, Engineering and Transport.

MAJOR ASPECTS OF STUDY:


Whole class was divided into 5 groups Job
done by each group is to design adistrict Introduction What are a District Centre and relation with
Center on the allotted site. population standards? Composition of the
Distt. Centre –Hotel, Shopping, Offices,
Eateries /Restaurants, Recreational, Services
and Public Facilities etc.
Services Drainage, Water, Sewerage Elect, ESS.

Facilities Public conveniences, Shelters, Food and


Beverages, Steps, Stairs Drinking water, Kiosks,
Telephone booths etc. Sitting Piazzas
Landscape Green and Paved, Lighting, Vehicular Traffic,
Pedestrians Movement, Shelters, Landscape
Allotted site furnishing etc.

Front Service road Road at the back


WHAT IS DISTRICT CENTER ?
District centres – Smaller than town centres, but still with good access and providing a range of
services for the local district area. These usually comprise groups of shops, often containing at least
one supermarket. District Centres will also contain a number of other services, often including,
community services, financial services and some small scale leisure services.

The shape and type of a district center almost always closely reflect the city's history. Cities with
maximum building height restrictions often have a separate historic section quite apart from the
financial and administrative district. In cities that grew up relatively quickly and more recently, A city's
district center is usually typified by a concentration of retail and office buildings. The district center
usually has an urban density higher than the surrounding districts of the city, and is often the location of
the tallest buildings in the city.
SITE ANALYSIS The site is located bang on
Yamuna Expressway and is
Coordinates an integral part of the
28.3076° N, 77.5631°E sports city , Greater Noida.
It is a great place for all
sports aficionados. Next to
Software Technolgy Park
with many multi national
companies and
sophisticated residential
properties, world class
educational institutes and
healthcare facilities. The
site is also in close proximity
to the ' BOULEVARD', which
is the spine that connects
the entire SPORTSCITY.
The Boulevard acts as a great linear 'living room' for the city , a place for the residents to
interact , relax , shop and enjoy the various amenities and activities lining it . The site is
connected by the Yamuna Expressway to the heart of Greater Noida Noida andDelhi.
LOCATION
Yamuna Expressway, Uttar Pradesh, India
Located bang on Yamuna Expressway.
Next to Software Technology Park with many
multi national companies and sophisticated
residential properties,

Important Landmarks :
Fl buddh international circuit 5.9 km
Jp international cricket stadium -17km
Sector 18 noida
Atta market noida
Galgotia university 12.8 km

State Uttar Pradesh

District Gautam Buddh Nagar


SITEANALYSIS
S.W.O.T ANALYSIS- GREATER NOIDA DISTRICT CENTER
STRENGTH WEAKNESS OVER COME OPPORTUNITY
•Properly designed landscape. •Surface water collection in
•Densevicinity
•Seperated pdestrian and roads storage tanks .
•Proper circulation. •Proper installation of fixture
•Justadjacenttoyamu
•Easy accessibility and wiring. na expressway
•Mix land use of offices,retail shopand •Proper drains. •Wel connectedfromnear
buyers. •Proper sanitation. byareawithproperroad.

THREATS OVER COME


•Proper security checks.
•Safe at night ,with 24 HRSactivity
and good lighting.
•Secured and safe for women.
•Mix land use.
SITE ANALYSIS
AREAS OF NEHRUPLACE AREAS OF DISTRICT CENTERG.NOIDA
Total formal retail shops = 12,900 sq. m Area of site = 233000 sqm.
approx Total paved area = 16,500 sq. m Ground coverage= 41937
approx Total informal retail shops= Open area = 191063 sqm.
9900250 sq. m approx Total formal retail shops=322,620sq.m
 Core complex office floors = G+8 Total
approx Total paved area = 36572sq. m
office area = 310,000 sq. m approx
 Area under office = 279600 sqm.
Tower floors = G+14 or more Total surface
 Total green area = 70743 sq. m approx
parking = 48,000 sq. m approx
Total of road = 52341 sqm.Approx
Total basement parking = 2,600 sq.m
approx Area ofresidence(apartments) =139800
Total multi-level parking = 24,000 sq.m sqm.
approx  Area of penthouses= 46,600 sqm.
Total parking area = 74,600 sq.m approx

AREACALCULATIONS
•Urban Design integrates the process and LITERATURE STUDY
expertise of many related disciplines including
Art , Architecture , Landscape, Social services,
Economics , Planning , Engineering and
Transport.
•upto 1960 - Planning & Architecturewere
split.
•" Planning" concentrated on Land Use
Pattern & connected socio economic issues
(MACRO)
•"Architecture" concentrated on the design of
mainly the Buildings (MICRO)

As such there emerged a "Responsibility Gap"


where the design of general public spaceswere
Concerned.
URBAN DESIGNthus came to Bridge in thisGap.
BYE– LAWS(DISTRICTCENTER)
MAXIMUM SETBACK
DISTRICTCENTER
MAXIMUM GROUND COVERAGE 25% S.NO PLOTSIZE FRONT REAR SIDE SIDE
MAXIMUM F.A.R 125 ( in sqm) SETBAC SETBAC SETBACK( SETBACK(
MAXIMUM HEIGHT 37m K K 1) 2)
1 UPTO60 0 0 0 0
OTHERCONTROLS
2 61 – 150 3 0 0 0
SOMEOFTHEBUILDINGS IN THEDISTRICT CENTER
COULD BEPERMITTED UPTO 50m HEIGHT WITH THE 3 151 - 300 3 3 0 0
APPROVAL OFGOVERNMENT FORACHIEVING AN 4 301 – 500 3 3 3 0
URBAN FORM. 5 501 –1000 6 3 3 3
BASEMENT9(s) UPTO THE BUILDING ENVELOPE LINE 6 1001 – 2000 9 3 3 3
TO THE MAXIMUM EXTENT OF PLOT AREA SHALL BE 7 2001 – 4000 9 6 6 6
ALLOWED AND IF USED FOR PARKING AND SERVICES 8 4001 – 10000 15 6 6 6
SHOULDNOTBECOUNTEDIN F.A.R. 9 ABOVE10000 15 9 9 9

ASPERMPD2021 DESIGNGUIDELINES
THEDISTRICT CENTERHAS THE
MAXIMUM COMMERCIAL WHOLESALE GOVERNMENT
CENTER MARKET OFFICES
FOLLOWINGCOMPONENTS:
REATAIL SHOPPING
COMMERCIAL OFFICES
GROUND 25 % 30 % 30 % SERVICECENTER
COVERAGE
F.A.R 150 80 200
FACILITIES
CULTURAL COMPLEX
BYE LAWS
HEIGHT NR* NR* NR* HOTEL
LANDSCAECOMPONENT
PARKING
STANDARD 3 3 1.8
WHOLESALE(WHEREPROVIDED)
ECS/100 SQM
OF FLOOR AREA

10% ADDITIONAL COVERAGESHALL BEALLOWEDFORPROVIDING


ATRIUM IN CASEOFCOMMERCIALCENTER
BYE– LAWS
CINEMAS/THEATERS/ FORGOVERNMRNTAL
TOILETS AUDITORIUM etc AND PUBLIC OFFICE
S.NO. FITMENTS (FOR PUBLIC) (FOR PUBLIC) (FOR STAFF) (FOR STAFF) FOR MALE FOR FEMALE
MALE FEMALE MALE FEMALE PERSONNEL PERSONNEL
1 WATER CLOSETS 1 PER 100 PERSONS 2 PER 100 PERSONS 1 FOR 1-15 1 FOR 1-12 1 FOR EVERY 25 1 FOR EVRY 15
UPTO 400 PERSONS UPTO 200 PERSONS PERSOMS PERSONS PERSONS OR PART PERSONS OR
FOR OVER 400,ADDAT FOR OVER 200 2 FOR 16-35 2 FOR 13-25 THEREOF PARTTHEREOF
THE RATE OF 1 PER 250 PERSONS,ADD AT THE PERSONS PERSONS
PERSONS OR PART RATE OF 1 PER 100
THEREOF PERSONS OR PART
THEREOF
2 ABLUTION TAPS 1 IN EACHWATER 1 IN EACHWATER 1 IN EACHWATER 1 IN EACH 1 IN EACHWATER 1 IN EACHWATER
CLOSET CLOSET CLOSET WATER CLOSET CLOSET
CLOSET
3 URINALS 1 FOR 50 PERSONS OR NIL UPTO6 NILL UPTO 6
PART THEREOF PERSONS 1 FOR 7-20
1 FOR 7-20 2 FOR 21-45
PERSONS 3 FOR 46-70
2 FOR 21-45 FOR OVER 200
PERSONS PERSONS ADD AT
THE RATE OF 2.5%
4 WASH BASINS 1 FOR EVERY 200 1 FOR EVERY 200 1 FOR 1-15 1 FOR 1-12 1 FOR EVERY 25 1 FOR EVERY 25
PERSONS RPART PERSONS OR PART PERSONS PERSONS PERSONS OR PART PERSONS OR
THEREOF THEREOF 2 FOR 16-35 2 FOR 13-25 THEREOF PART THEREOF
PERSONS PERSONS

BYE LAWS
BYE– LAWS(BASEMENT)
DELHI BUILDING BYE- LAWS

(A)the basement shall not be used for residentialpurposes. (G)the access to the basement shall be seprate from main and alternate
(B) atleast 2.4m in height from thefloor staircase providing access and exit form higher florrs.
(C)adequate ventilation shall be provided for thebasement(one (H)in case of basments for office and commercial occupancies sufficient
exhaust fan for 50sqm of basementarea). number of exi ways and access ways shall be provided with a travel
(D)the minimum height of the ceiling of any basement shall be 0.9m distance ot more than15m.
and maximum of 1.2m above the average surrounding ground level. (I) the basement shall not bepartitioned.
(E)surface drainage doesnot enter the basement causing dampness.
(F) the walls and floors of the basement should be water tight and be so
designed that the effect of the surrounding soil and moisture,if any,are MULTI-LEVEL PARKING
taken into account in design and adequate damp proofing treatment is Multi-level parking facility shulod be preferably be developed in the
given. designated parking spaces or in theresidential, public – semi public
facilities, commercial, transport mode,dtc depot etc. With thefollowing
BASEMENT IN OTHERBUILDINGS(AS PERDEVELOPMENTCODE) developmental controls;
(A)basement(s) upto setback line maximum equivalent to parking and MINIMUM PLOTSIZE– 1000sqm
services requirement, such as air conditioning plantand equipment,water In order to compensate the cost of multi-level parking also to fulfill the
storage,bioler,electric sub station,ht and lt panel room,transformer growing need of parking spaces within urban area, a maximum of 25%
compartment,control room,pump house,generator room and other of gross floor area may be utilized as commercial/officespace.
mechanical services required for the maintenance of the building with pri or In addition to the permissible parking spaces onmax. Far, 3 times
approval of the concerned agencies,could be permitted and not to be additional space for parking component shall beprovided.
counted in f.A.R. However,the area shuold not excwwd 30% of the Maximum far permissible shall be 100 (excluding parking area) or as per
basement area. the comprehensive scheme. However, no far shall be permitted in
(B)the basement(s) above the plot level shall be kept flushed with the plots/existingbuildings where 5% addl. Ground coverage is permissible.
ground and shall be ventilated with mechanicalmeans of ventilation:and Maximum ground coverage shall be 66.6% .Maximum height shall be
(C)basement(s) shall be designed to take full load of the dire tender, restricted to permissible height of the land use i n which the plot falls.
wherever required and subject to adequate safetymeasures. Number of basements – no limit, subject to adequate safety measures.
BASEMENT IN CASEOFBUILDING MORE THAN 15m IN HEIGHT For development of multi-level parking, models should be worked out
Each basement shall be seprately ventilated. Vents with cross sectional to encourage the private sector initiative with restricted commercial
area not less than 2.5% of the floor area spared evenly round the component not exceeding 10% limited to far 40 on theplot.
perimeter of the basement shall be provided in the form of grills or Specific proposals requiring relaxation in above – mentioned norms
breakable stall-boards liht or payment light or by way of shafts. would be reffered to theauthority.
The staircase of basements shall be of enclosed type having fire
resistance of not less than two hours and shall be situated at the
periphery of the basement and shall communicate with basement
BYE LAWS
through a lobby provided with fire resisting self – closing doors ofhalf-
hour fire resistance.If the travel distance exceeds 18.50m ADDITIONAL
STAIRCASEAT PROPERPLACESSHALLBEPROVIDED.
BYE -LAWS(EXITWAYS)
GENERAL CAPACITY OF EXITS: ARRANGEMENT OF EXITS:
• Every building meant for human occupancy shall be provided with The capacity of exits ( doors & Exits shall be so located that the
exists sufficient to permit safe esacape of occupants in case of fireor Stairways) indiacating the no. of travel distance on the florr shall
other emergency. Persons that could be safely not be exceed 22.5m for
• All exits shall be free of obstruction. Evacuated through a unit exit width residential , educational,
• Exits shall be clearly visible and the routes toreach the exit shall be of 50cm . institutional and hazardous
clearly marked with signage. NO. & SIZE OFEXITS: occupancies and 30m for assembly
• No buildings shall be altered so as to reduce the number,width or The requisite no. & Size of various business , storage occupancies
pprotection of exits less than required. exit Shall be provided , based on the Whenever more than one exit is
• All exits way shall be properlu illuminated. Population in each room ,area required for a floor of a building ,
• Fire fighting equipments where provided along exits shal be suitably And floor based on the occupant exits shall be placed as remote
located and clearly marked out. Load capacity of exits , travel distance from each other as possible .
• Alarm devices shall be installed. .And height of the buildingsas per
• Lifts and escalators shall not be considered asexits. Provisions of bye laws.
DOORWAYS
• Every doorway shall open into an enclosed stairway , a horizontal exit , on a corridor providing continious and protected means ofegress.
• No exit doorway shall be less than 100cm in width and shall not be less than 200cm in height.
• Each doorway shall open outwards , i.E. Away from the room but shal not obstruct the travel along any exit. No door , when opened , shall
reduced the required width of stairway or landing to less than 90cm , overhead and sliding door shall not be installed .
• Exit door shall not be open immediately upon a flight or stairs : a landing equal to atleast the width of the floor shall be provided in the stairway
at eachdoorway.
• Exit doorways shall be openable from the side which they serve without the use of akey.
STAIRWAYS
• Interiors shall be constructed ofnon combustible materials.
• Interior staircase shall be constructed as a self contain unit with atleast one side adjacent to an external wall and shall be completely enclosed.
FORBUILDINGS MORE THAN 15mm HEIGHT , ALLSTAIRCASESHALLBEENCLOSED.
• A staircase shall not be arranged round a lift shaft unless the latter is entirely enclosed by a material of fire resistance rating as that for type of
construction itself.
• Hollow combustible construction shall not bepermitted.
• The minimmum width of interna staircase shall be1m.
• In case of building other than residential , the minimum tread shall be30cm.

BYE LAWS
The maximum height of riser shall be 15cm and limited to 12 flights.
• Handrails shall be provided with a minimum height of 90cm from the center of the tread .
• The minimm headroom of stairways shall be 2.2m.
• NO LIVING SPACEOROTHERFIRERISKSHALLOPENDIRECTLYINTO THESTAIRCASEORSTAIRCASES.
• EXTERNALEXITDOOROFSTAIRCASEENCLOSUREAT GROUNDLEVELSHALLOPENDIRECTLYTOTHEOPENSPACES.
• In case of single staircase it shall terminate at the ground floor level and the access to the basement shall be by a seprate staircase. However
the second staircase may lead to the basementlevels.
LAYOUT PLAN
LANDSCAPE PLAN
BUILUP DISTRIBUTION PLAN
SERVICES ELECTRICALPLAN
SERVICES DRAINAGE PLAN
ROADS AND PEDESTRIAN
3-D VIEWS