FlexILS provides a toolbox for creating an optimized flex-grid based line system
2 | Infinera Confidential & Proprietary
FlexILS Coherent Optimized Amplifiers
IAM1 and IAM2 EDFAs IRM1 Hybrid Raman Amplifier
Module Type Degrees C CDC OSA Power Express Integrated WSS Ports MTC-n
Balancing Config Amp slots
FRM-20X Route and 9* Per FSP-E 20 1
Select Channel
FRM-9D Route and 9* Per FSP-E 16 3
Select Channel
FRM-4D Broadcast 4 Per Direct (28dB 6 2
and Select Channel LC-LC with OSC)
FSP-E
Optical Express shuffle panel
FRM-20X
FRM-20X
FMM-C-12 FSM-CDC
FSP-C FSP-C
500G
500G
Add/Drop 500G
500G
Add/Drop Contentionl
Mux
Mux panel
panel Contentionl
4T ess
ess
4T per
per add/drop:
panel
panel add/drop:
6T
6T per
per
module
module 100G
100G
MTC-n 100G
100G
500G
MTC-n
500G
AOFx-100
AOFx-100
AOFx-500
AOFx-500
AOFx-100
AOFx-100
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-100
AOFx-100
AOFx-500
AOFx-500
AOFx-100
XT-500F
AOFx-100
XT-500F
XT-500F
XT-500F
XTC-10/4/2/2E ; XT-500F/ 3600F
7 | Infinera Confidential & Proprietary
FRM-4D Node options
To other express To other express
degrees degrees
Inter Degree
FRM-4D FRM-4D
Connection
IRM
100G
100G
Passive
Passive
100G Mux(TM)
Mux(TM)
100G
Add/Drop. for
for
Add/Drop.
500G Coherent
Coherent
500G per
per 500G
500G Add/Drop
Add/Drop
FMM-C-5 CFP
CFP and
and
FMM-C-5 9.5T
9.5T per
per FMM-
FMM- AOFx-100
AOFx-100
F250
F250
100G
100G
MTC-n MTC-n
XT-500F
XT-500F
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
XTC-10/4/2/2E: XT-500F/3600F
8 | Infinera Confidential & Proprietary
“Automate Everything”
Extending “Ease Of Use” from Digital to Photonic Domain
Digital Photonic
Domain Domain
Auto-Discovery
P P
Hello Hello
Topology/Node Discovery
Inventory and Configuration Management
Bottom line:
ADAPT • Easy to deploy
P P
Automatic adjustment & monitoring of
WDM parameters • Simple to operate
“Hands-free” link turn-up & optimization • Self healing
Network with high
GMPLS: WSON*/SSON* efficiency
Route Computation
Point and Click Provisioning P P
Network
Failure
Restoration
<50ms Digital FastSMP protection
Auto-Restored Multi-second Optical GMPLS restoration
Traffic
P P
9 | Infinera Confidential & Proprietary *Future release
FlexILS: Photonic Chassis (MTC-9)
R P
1510 nm SFP
MPD 1
Broadcast and Select Architecture
OSA
MPD 2
MPD 11 OUT
• Splitters in demux direction
OPM IN 1
OP M
SYSTEM 4 OUT
SYSTEM 5 OUT
65/35
1X3
1490 MPD 12
MPD 10
SYSTEM 4 IN
1x6 WSS
MPD 7
1X3 MPD 6
SYSTEM
SYSTEM
5 IN
6 IN
Flexible use of 6 SYSTEM ports
• Up to 3 express ports (fixed 3 which can be express)
• Up to 6 add-drop ports (any ports not being used for
MPD 3 MPD 4 MPD 5
SYSTEM 3 I N
SYSTEM 1 OUT
SYSTE M 2 OUT
SYSTEM 3 OUT
SYSTEM 1 I N
SYSTEM 2 I N
express)
Per channel power monitoring and balancing
OSA Monitoring Port
FSP-E
FRM4 FRM4
FRM8 FRM8
FRM7 FRM5
FRM7 FRM5
FRM6 FRM6
Degree
2
FRM-9D-R
Provides CDC functionality along
IAM/IRM
with FRM-9D-R
• Multiples of same l can be add/drop to same
Degree
N FSM
FSM
Degree 1
MTC-9
• Can be connected to multiple FRM-9D-R
(directions)
LM LM LM
500 G Add-Drop
Super-Channel
Line Modules Direction independent add/drop
XTC
• Mux/Demux and switching of 12 channels to 8
directions
FSM Faceplate
• Up to 8D CDC FlexROADM Node
3 slots in MTC-n
Bidirectional 5D-9D 2 4
MPO Connector
Fiber Pair
Number of FSP-S Required
34 | Infinera Confidential & Proprietary
Roofing filter on FMM-C-5 (BPP)
OSA Line Out SYSTEM 4-6 IN
SYSTEM 1 IN
Line Out
1X6 SYSTEM 2 IN BPP for AOFx-100 add/drop to FRM-
WSS SYSTEM 3 IN
4D
OPM
OSC
SYSTEM 1 OUT
Provides limited spectrum/
Line In
1
1x
3
SYSTEM 2 OUT
SYSTEM 3 OUT
frequencies accessibility for AOFx-
x
3
SYSTEM 4-6 OUT
100 receiver for better sensitivity.
Auto Discovery pass through
BPP 3 variants of BPP completes 4.8THz
FMM-C-5
FBM cards Allow for sliceable cost efficient CDC routing for ICE
optical engines
Four variants
• FBM-SLCDC-8-2-USB – up to 2 degrees
• FBM-SLCDC-8-4-USB – up to 4 degrees
• FBM-SLCDC-8-8-USB – up to 8 degrees
• FBM-SLCDC-8-12-USB – up to 12 degrees**
8 LC ports for Line Cards
2 to 8 MPO ports for connection to WSS cards
Optically passive, have MPDs for auto-discovery and
power measurements
MPC-6 carrier USB connectivity to control plane
• USB cable supplies power for MPDs and controller
Hosted in MPC-6 passive chassis (1RU)
• Each FBM takes half of that carrier
• Not compatible with FRM-4D
Connectors toward ROADM card
• MPO
Connectors toward Line Cards
• Four add/drop port pairs (8 ports total, each pair power combined/split)
• For best 16QAM performance the number of carriers per add/drop port
pair should be limited to 12 (48 carriers per FBM-SLCDC-8-8)
• LC
Connects
• Up to 8 Line Cards
• Up to 8 ROADMs
Supports auto-discovery
ICE4 LM ICE4 LM
Wavelength selection is done in ROADMs in both add
λ1 and drop directions
* See Infinera roadmap for availability
38 | Infinera Confidential & Proprietary λ2 See Backup Slides for more details
Fiber Shuffle Panels FSP-CE
FRM-20X
FRM-20X
FRM-20X
FRM-20X Base FRM
FSP-CE-2MPO-1LC
FSP-CE-2MPO-2LC
Extender FRM
FRM-20X
FRM-20X
FRM-20X
FRM-20X
FRM-20X
FRM-20X
FBM-SLCDC FBM-SLCDC FBM-SLCDC
NODE A NODE B
AOFx AOFx
FMP-F
FMP-F
FMP-F
FMP-F
FMP-F
FMP-F
3dB
3dB
AOFx
AOFx restoration supported via GCC0
9.5Tb/s at 17dB between AOFx-500 LM pair
Super-Channel FlexROADM
FRM-9D FRM-9D
• 19 x 500G Super-Channels
Express • 9.5T fiber capacity over extended C band
FMM-F250 FMM-F250
FMM-F250 acts as colored
FSP-C
FSP-C FSP-C
FSP-C
FlexChannel MUX
• 100% add/drop on single FRU
• Occupy two FRM ports
MTC-n MTC-n
Benefits: Cost-optimized
AOFx-500
add/drop
XTC/ XT
AOFx-500
AOFx-500
XT-500F
XT-500F
XT-500F
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
degree
Terminal 4 8T
XTC/XT
2 to 4 degrees 3 6T
5 to 8 degrees 2 4T
47 | Infinera Confidential & Proprietary
Colorless with FMP-C: FRM-9D
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
capacity per
degree
Terminal 4 9.5T
XTC/X
T 2 to 4 degrees 3 9.5T
5 to 8 degrees 2 8T
48 | Infinera Confidential & Proprietary
Direct Connect Colorless ROADM: FRM-4D
To other express
degrees
To other express
degrees
Direct Connect: AOFx-500 super-
FRM 4D
Inter Degree
Connection FRM 4D channel line module connects
IRM IRM
directly to FRM 4D
LINE LINE
Low cost add/drop option
• No channel mux needed(FMM-F/C)
• Enables “pay as you play” deployment of channel
MTC-n MTC-n mux for high-degree/high add-drop applications
Direction specific Add/Drop
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
AOFx-500
XT-500F
XT-500F
AOFx-500
AOFx-500
AOFx-500
AOFx-500
XTC switching
• Future proof with AOFx-1200
FSM1 FSM2 FSM3 FSM4 FSM1 FSM2 FSM3 FSM4 FSM5 FSM6 FSM7
• 1 MPO from each FRM gets connected to FSP-S • 2 MPO from each FRM gets connected to two different FSP-S
• 1 MPO from each FSM gets connected to FSP-S • 1 MPO from each FSM gets connected to FSP-S
FSP-E
Optical Express
FRM-20X
shuffle panel
FRM-20X
FSP-C
AOFx-500
XT-500F
LC connector/fiber
MPO connector/fiber
53 | Infinera Confidential & Proprietary
Configurations for AOFx-100
AOFx-100
1(Terminal) 3T
2 2.5T
3 2T
4 1.5T
AOFx-100
1(Terminal) 6 3T
2 5 2.5T
3 4 2T
4 3 1.5T
AOFx-100
with 4 fiber pair in each MPO)
FSP-C provides MPO breakout to 4 LC
ports to FMM-C-5
FSP-C
FSP-C
AOFx-100 No. of Degrees Total Add/drop per
degree
AOFx-100
Terminal 8T
2 to 4 degrees 6T
5 to 8 degrees 4T
AOFx-100
(odd ITU)
AOFx-100
AOFx-100
FRM-4D Passive 40 channel AWG MUX
IAM-2
AWG MUX • CO-40 Odd/Even occupies 1 RU
• MDU-40 Odd/Even with and with out VOA
L
M occupies two slots in TM-3000
M
AOFx-100
Max fiber capacity of 8T with AOFx-
AOFx-100
IAM-2
100
AOFx-100
AWG MUX
AOFx-100
(odd ITU) 1 RU passive 40 channel AWG MUX
AOFx-100
• CO-40 Odd/Even occupies 1 RU
FRM-9D
AOFx-100
IAM-2
• MDU-40 Odd/Even with and with out VOA
occupies two slots in TM-3000
AWG MUX
L
M FSP-C
FSP-C Max fiber capacity of 8T with AOFx-
M
AOFx-100
100
AOFx-100
IAM-2
Future proof design
AWG MUX
AOFx-100
• ROADM ports available for adding next gen line
(even ITU) modules for high spectral efficiency
IAM/IRM
FMM-C-5 FMM-C-5
IAM/IRM
FMM-C provides colorless
functionality
FMM-C-5 FMM-C-5
• 5 local Add/Drop ports per FMM-C
• Multiple FMM-C for add/drop with BPP filter(3
variants to cover entire extended C band)
MTC-n MTC-n Benefits:
• Any line card on any add/drop port
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
AOFx-100
BPP filter
• Reduce truck-rolls for reconfiguring line cards
per direction
XTC
Return
61 | Infinera Confidential & Proprietary
Colorless Add/Drop with FMM-C-12
To other express
degrees
Inter Degree
Connection
To other express
degrees
FMM-C-12: active Fiber MUX module
FRM-9D FRM-9D
• Colorless mux
• Muxes 12 alien carriers into one WSS port of FRM-9D
FSP-E
IAM/IRM
FSP-C IAM/IRM • Installed in MTC chassis (1 slot)
FSP-C
Flexible configuration
FSP-C FSP-C • Supports Infinera line modules (via FMP-C) and alien
transponders via FMM-C-12/FSP-C
• 100% add/drop capacity in all configuration
(up to 9-degree ROADM node)
MTC-n FMM-C-12 FMM-C-12
1 12 1 12
MTC-n
L L L L
M M M M
* FMM-C-12 future
ROADM/
FRU Mode Mux ILS Connection Type FOADM Comments
XT-3300 OpenMode)
Wave (SCG FSP-C-1D-1MPO-4LC Direct FRM-9D XT-3300 as standalone NE(running R17.0) connecting to FRM-9D running
R16.3
XT-3300 OpenMode)
Wave (SCG FSP-C-1D-1MPO-4LC Direct FRM-20X XT-3300 and FRM-20X are in the same NE (running R17.0)
XT-3300 OpenMode)
Wave (SCG FBM-SLCDC Mux FRM-20X XT-3300 and FRM-20X are in the same NE (running R17.0)
XT-3300 OpenMode)
Wave (OCG BMM-2C 33 Gbaud Channels (muxing internal to BMM-2C). XT-3300 as standalone
NA Direct (running R17.0) connecting to BMM2C running R16.3
FRM-9D
FRM-9D
FSP-C
FSP-C
FSP-C
FSP-C
XT-3300 XT-3300
FRM-20X
ILA ILA
FRM-20X
FSP-C
FSP-C
FSP-C
FSP-C
16
16
XT-3300 Open Wave (SCG FBM-SLCDC Directionless Colorless FRM-20X XT-3300 in same NE as FRM-20X. The NE is on R17.0
Mode) Mux
AOLx(2)/ XT-500S (running R16.3) connecting to FRM-20X (running R17.0).
AOLx(2)-
500/ XT- Open Wave FSP-C* / FMP-C Direct or Power mux FRM-20X DTN-X and ILS in separate NEs.
*Only one of the paired OCG can be used. (eg. If OCG1 is add/dropped,
500S then OCG9 can’t be used)
AFOx- AOFx-500 / XT-500F (running R16.3) connecting to FRM-20X (running
500 / XT- Open Wave FSP-C / FMP-C Direct or Power Mux FRM-20X R17.0). DTN-X and ILS in separate NEs.
500F
Alien
(Single True Alien source FMM-C-12<--->FBM-SLCDC Directionless Colorless FRM-20X CD configuration
wave Mux
coherent)
Alien
(Single True Alien source FMM-C-12<--->FSP-C Colorless mux FRM-20X Directional configuration
wave
coherent)
FBM-SLCDC FBM-SLCDC
FMM-C-12
FSP-E
FRM-20X
FSP-C
Using one
MPO only
FBM-SLCDC-8-2
FMM-C-12
FSP-E
Optical Express
FRM-20X
shuffle panel*
FRM-20X
FSP-C FMP-C
FSP-C Only one of the paired OCG can be
used. (eg. If OCG1 is add/dropped,
then OCG9 can’t be used).
AOLX(2)-500 This is due to the limitation of WSS in FRM-20X
AOFx-500 AOLX(2)-500 which can currently support 37.5GHz Channel
XT-500F spacing.
XT-500S XT-500F
LC connector/fiber
MPO connector/fiber
72 | Infinera Confidential & Proprietary
73 | Infinera Confidential & Proprietary