Sunteți pe pagina 1din 16

Channel configuration of timeslot 0

0 1 2 3 4 6 7 BCCH-carrier

BCH CCCH DCCH

FCCH SCH BCCH PCH AGCH SDCCH/CBCH SACCH


EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 1 GSM Advanced Cell Planning
Non-combined mapping of BCHs and CCCHs on
timeslot 0, downlink

FCCH FCCH FCCH FCCH FCCH Idle


SCH SCH SCH SCH SCH

BCCH CCCH CCCH CCCH CCCH CCCH CCCH CCCH CCCH CCCH
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 2 GSM Advanced Cell Planning
Combined mapping of BCHs, CCCHs and SDCCHs
on timeslot 0, downlink

FCCH FCCH FCCH FCCH FCCH Idle


SCH SCH SCH SCH SCH

BCCH CCCH CCCH CCCH SDCCH SDCCH SDCCH SDCCH SACCH SACCH
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 3 GSM Advanced Cell Planning
A paging block can fit two IMSI pages or four TMSI
pages or a combination of one IMSI and two TMSI

IMSI IMSI

T T T T T = TMSI

IMSI T T
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 4 GSM Advanced Cell Planning
The graph presents the limitations of the traffic for
different number of cells in the BSC
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 5 GSM Advanced Cell Planning
The graph presents the maximum number of TRXs
in the BSC
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 6 GSM Advanced Cell Planning
Appendix A, max SDCCH/TCH ratio
1 TRX

SDCCH configuration Number of Capacity, Number of Capacity, Max.


SDCCH SDCCHs TCHs TCH SDCCH/TCH-
subchannels ratio

SDCCH/4 4 (3) 0.87 (0.46) 7 2.9 30% (16%)

SDCCH/8 8 (7) 2.7 (2.2) 6 2.3 120% (94%)

2 TRXs

SDCCH configuration Number of Capacity, Number of Capacity, Max.


SDCCH SDCCHs TCHs TCH SDCCH/TCH-
subchannels ratio

SDCCH/4 4 (3) 0.87 (0.46) 15 9.0 9.7% (5.1%)

SDCCH/8 8 (7) 2.7 (2.2) 14 8.2 33% (27%)

SDCCH/4 + SDCCH/8 12 (11) 5.3 (4.6) 14 8.2 65% (56%)

2 * SDCCH/8 16 (15) 8.1 (7.4) 13 7.4 109% (100%)

3 TRXs

SDCCH configuration Number of Capacity, Number of Capacity, Max.


SDCCH SDCCHs TCHs TCH SDCCH/TCH-
subchannels ratio

SDCCH/4 4 (3) 0.87 (0.46) 23 15.8 5.5% (2.9%)

SDCCH/8 8 (7) 2.7 (2.2) 22 14.9 18% (15%)


EN/FAD 109 0015

SDCCH/4 + SDCCH/8 12 (11) 5.3 (4.6) 22 14.9 36% (31%)

2 * SDCCH/8 16 (15) 8.1 (7.4) 21 14.0 58% (53%)

038 13 - LZU 108 881 Rev B Figure 3 - 7 GSM Advanced Cell Planning
Appendix A, max SDCCH/TCH ratio

4 TRXs
3*SDCCH/8 24 (23) 14.2 (13.4) 44 34.7 41% (39%)
SDCCH configuration Number of Capacity, Number of Capacity, Max.
SDCCH SDCCHs TCHs TCH SDCCH/TCH- 2*SDCCH/8 + SDCCH/4 20(19) 11.1 (10.3) 45 35.6 31% (29%)
subchannel ratio
s 2*SDCCH/8 16 (15) 8.1 (7.4) 45 35.6 23% (21%)

SDCCH/8 8 (7) 2.7 (2.2) 30 21.9 12% (10%) SDCCH/4 + SDCCH/8 12 (11) 5.3 (4.6) 46 36.5 15% (13%)

SDCCH/4 + SDCCH/8 12 (11) 5.3 (4.6) 30 21.9 24% (21%) subchannels ratio
SDCCH SDCCHs TCHs TCH SDCCH/TCH-
2*SDCCH/8 16 (15) 8.1 (7.4) 29 21.0 39% (35%) SDCCH configuration Number of Capacity, Number of Capacity, Max.

6 TRXs
2*SDCCH/8 + SDCCH/4 20(19) 11.1 (10.3) 29 21.0 53% (49%)

7 TRXs
5 TRXs
SDCCH configuration Number of Capacity, Number of Capacity, Max.
SDCCH configuration Number of Capacity, Number of Capacity, Max. SDCCH SDCCHs TCHs TCH SDCCH/TCH-
SDCCH SDCCHs TCHs TCH SDCCH/TCH- subchannels ratio
subchannels ratio
SDCCH/4 + SDCCH/8 12 (11) 5.3 (4.6) 54 44.0 12% (10%)
SDCCH/4 + SDCCH/8 12 (11) 5.3 (4.6) 38 29.1 18% (16%)
2*SDCCH/8 16 (15) 8.1 (7.4) 53 43.1 19% (17%)
2*SDCCH/8 16 (15) 8.1 (7.4) 37 28.3 29% (26%)
2*SDCCH/8 + SDCCH/4 20(19) 11.1 (10.3) 53 43.1 26% (24%)
2*SDCCH/8 + SDCCH/4 20(19) 11.1 (10.3) 37 28.3 39% (36%)
3*SDCCH/8 24 (23) 14.2 (13.4) 52 42.1 34% (32%)
3*SDCCH/8 24 (23) 14.2 (13.4) 36 27.3 52% (49%)
3*SDCCH/8 + SDCCH/4 28 (27) 17.4 (16.6) 52 42.1 41% (39%)
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 8 GSM Advanced Cell Planning
Appendix B, max SDCCH/TCH ratios
1 TRX

SDCCH configuration Number of Capacity, Number of Capacity, Max.


SDCCH Signalling TCHs TCH SDCCH/TCH-
subchannels SDCCH + ratio
TCH

SDCCH/4 4 (3) 2.8 (2.0) 7 2.9 117% (83%)

SDCCH/8 8 (7) 5.8 (5.0) 6 2.3 322% (278%)

2 TRX

SDCCH configuration Number of Capacity, Number of Capacity, Max.


SDCCH Signalling TCHs TCH SDCCH/TCH-
subchannels SDCCH + ratio
TCH

SDCCH/4 4 (3) 2.8 (2.0) 15 9.0 33% (24%)

SDCCH/8 8 (7) 5.8 (5.0) 14 8.2 75% (65%)

3 TRX

SDCCH configuration Number of Capacity, Number of Capacity, Max.


SDCCH Signalling TCHs TCH SDCCH/TCH-
subchannels SDCCH + ratio
TCH

SDCCH/4 4 (3) 2.8 (2.0) 23 15.8 18% (14%)

SDCCH/8 8 (7) 5.8 (5.0) 22 14.9 40% (35%)


EN/FAD 109 0015

SDCCH/4 + SDCCH/8 12 (11) 9.1 (8.3) 22 14.9 63% (58%)

038 13 - LZU 108 881 Rev B Figure 3 - 9 GSM Advanced Cell Planning
Appendix B, max SDCCH/TCH ratios
4 TRX 6 TRX

SDCCH configuration Number of Capacity, Number of Capacity, Max. SDCCH configuration Number of Capacity, Number of Capacity, Max.
SDCCH Signalling TCHs TCH SDCCH/TCH- SDCCH Signalling TCHs TCH SDCCH/TCH-
subchannels SDCCH + ratio subchannels SDCCH + ratio
TCH TCH

SDCCH/4 4 (3) 2.8 (2.0) 31 22.8 13% (9%) SDCCH/8 8 (7) 5.8 (5.0) 46 36.5 16% (14%)

SDCCH/8 8 (7) 5.8 (5.0) 30 21.9 27% (23%)


SDCCH/4 + SDCCH/8 12 (11) 9.1 (8.3) 46 36.5 25% (23%)

SDCCH/4 + SDCCH/8 12 (11) 9.1 (8.3) 30 21.9 43% (39%)


2* SDCCH/8 16 (15) 12.4 (11.5) 45 35.6 35% (33%)

2* SDCCH/8 16(15) 12.4 (11.5) 29 21.0 60% (56%)


2* SDCCH/8 + SDCCH/4 20 (19) 15.8 (15.0) 45 35.6 45% (43%)

5 TRX 7 TRX

SDCCH configuration Number of Capacity, Number of Capacity, Max. SDCCH configuration Number of Capacity, Number of Capacity, Max.
SDCCH Signalling TCHs TCH SDCCH/TCH- SDCCH Signalling TCHs TCH SDCCH/TCH-
subchannels SDCCH + ratio subchannels SDCCH + ratio
TCH TCH

SDCCH/8 8 (7) 5.8 (5.0) 38 29.1 20% (17%) SDCCH/8 8 (7) 5.8 (5.0) 54 44 13% (11%)

SDCCH/4 + SDCCH/8 12 (11) 9.1 (8.3) 38 29.1 32% (29%)


SDCCH/4 + SDCCH/8 12 (11) 9.1 (8.3) 54 44 20% (19%)

2* SDCCH/8 16 (15) 12.4 (11.5) 37 28.3 45% (42%)


2* SDCCH/8 16 (15) 12.4 (11.5) 53 43.1 29% (27%)

2* SDCCH/8 + SDCCH/4 20 (19) 15.8 (15.0) 53 43.1 37% (35%)


EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 10 GSM Advanced Cell Planning
Appendix C, max SDCCH / TCH ratio
Half Rate Penetration: 5% Half Rate Penetration: 10%
No Cell Broadcast No Cell Broadcast

SDCCH Number of TRXs Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 30% [AC,IC] 10% 5% SDCCH/4 30% [AC,IC] 9% 5%


SDCCH/8 93% [BC] 33% 17% 12% SDCCH/8 93% [BC] 30% [AC,IC] 17% 12%
[AC,IC,BC]

SDCCH/8+SDCCH/4 64% 33%[AC,IC,BC] 28% [AC,IC,] 18% 14% 12%


SDCCH/8+SDCCH/4 59% [BC] 33%[AC,IC,BC] 24% [AC,IC] 17% 14% 11%

2*SDCCH/8 109% 54% 37% [BC] 28% [AC,IC] 22% [IC] 18% 2*SDCCH/8 99% 54% 37% [BC] 27% [AC,IC] 22% [IC] 18%

2*SDCCH/8+ 51% 37% [BC] 30% [AC,BC] 25% [AC,IC] 2*SDCCH/8+ 51% 36% [BC] 30% [AC,BC] 24% [AC,IC]
SDCCH/4 SDCCH/4

3*SDCCH/8 50% 40% 33% [BC] 3*SDCCH/8 49% 39% 32% [BC]

Half Rate Penetration: 5% Half Rate Penetration: 10%


Cell Broadcast used Cell Broadcast used

SDCCH Number of TRXs Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 16% 5% 3% SDCCH/4 16% 5% 3%


SDCCH/8 75% 27% [AC,IC] 14% 10% SDCCH/8 75% 24% [AC,IC] 14% 10%
[AC,IC,BC] [AC,IC,BC]
SDCCH/8+SDCCH/4 56% [BC] 29% [AC,IC] 21% [IC] 15% 14% 10% SDCCH/8+SDCCH/4 51% [BC] 29%[AC,IC] 21% [IC] 15% 12% 10%
2*SDCCH/8 100% 50% [BC] 34% [AC,BC] 25% [AC,IC] 20%[IC] 17% 2*SDCCH/8 90% 50% [BC] 34% [AC,BC] 25% [AC,IC] 20% [IC] 16%
2*SDCCH/8+ 47% 34% [BC] 28% [AC,BC] 23% [IC] 2*SDCCH/8+ 47% 33% [BC] 28% [AC,BC] 22% [IC]
SDCCH/4
SDCCH/4
3*SDCCH/8 47% 38% 31% [AC,BC]
EN/FAD 109 0015

3*SDCCH/8 46% 37% 30% [AC,BC]

038 13 - LZU 108 881 Rev B Figure 3 - 11 GSM Advanced Cell Planning
Appendix C, max SDCCH / TCH ratio
Half Rate Penetration: 15% Half Rate Penetration: 20%
No Cell Broadcast No Cell Broadcast

SDCCH Number of TRXs Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7
SDCCH/4 24% [AC,IC] 9% 5% SDCCH/4 24% [AC,IC] 9% 5%
SDCCH/8 75% [BC] 30% [AC,IC] 16% 12%
SDCCH/8 75% [BC] 30% [AC,IC] 16% 11%
SDCCH/8+SDCCH/4 59% [BC] 32%[AC,IC] 23% [IC] 17% 13% 11%
SDCCH/8+SDCCH/4 59% [BC] 32%[AC,IC] 22% [IC] 16% 13% 11%
2*SDCCH/8 99% 51% [BC] 36% [AC,BC] 26% [AC,IC] 21% 17%
2*SDCCH/8 99% 51% [BC] 34% [AC,BC] 25% [AC,IC] 21% 17%
2*SDCCH/8+ 49% 35% [BC] 29% 24% [AC,IC]
SDCCH/4 [AC,IC,BC] 2*SDCCH/8+ 47% 34% [BC] 28% [AC,IC] 23% [IC]
SDCCH/4
3*SDCCH/8 47% 38% [BC] 31% [BC]
3*SDCCH/8 46% 37% [BC] 30% [AC,BC]

Half Rate Penetration: 15% Half Rate Penetration: 20%


Cell Broadcast used Cell Broadcast used

Number of TRXs SDCCH Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 13% 5% 3% SDCCH/4 13% 5% 3%

SDCCH/8 61% 24% [AC,IC] 13% 10% SDCCH/8 61% 24% [AC,IC] 13% 9%
[AC,IC,BC] [AC,IC,BC]

SDCCH/8+SDCCH/4 51% [BC] 28%[AC,IC] 20% [IC] 14% 12% 10% SDCCH/8+SDCCH/4 51% [BC] 28%[AC,IC] 19% 14% 11% 9%

2*SDCCH/8 90% 47% [BC] 32% [AC,BC] 24% [AC,IC] 19% 16% 2*SDCCH/8 90% 47% [BC] 31% [AC,IC] 23% [IC] 19% 15%

2*SDCCH/8+ 43% [BC] 31% [AC,BC] 26% [AC,IC] 22% [IC]


2*SDCCH/8+ 45% 32% [BC] 27% [AC,IC] 22% [IC]
SDCCH/4
SDCCH/4
3*SDCCH/8 43% 35% [BC] 29% [AC,BC]
3*SDCCH/8 45% 36% [BC] 29% [AC,BC]
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 12 GSM Advanced Cell Planning
Appendix C, max SDCCH / TCH ratio
Half Rate Penetration: 25%
No Cell Broadcast

Number of TRXs
SDCCH configuration
1 2 3 4 5 6 7

SDCCH/4 24% [AC,IC] 8% 5%

SDCCH/8 75% [BC] 28% [AC,IC] 15% 11%

SDCCH/8+SDCCH/4 54% [BC] 30%[AC,IC] 22% [IC] 16% 13% 10%

2*SDCCH/8 90% 49% [BC] 33% 25% [AC,IC] 20% 16%


[AC,BC]

2*SDCCH/8+ 45% 33% [BC] 27% [AC,IC] 22% [IC]


SDCCH/4

3*SDCCH/8 46% 36% [BC] 30% [AC,BC]

Half Rate Penetration: 25%


Cell Broadcast used

SDCCH Number of TRXs


configuration
1 2 3 4 5 6 7

SDCCH/4 13% 4% 2%

SDCCH/8 61% 22% [IC] 13% 9%


[AC,IC,BC]

SDCCH/8+SDCCH/4 47% [AC,BC] 26%[AC,IC] 19% 14% 11% 9%

2*SDCCH/8 82% 45% [BC] 30% [AC,IC] 23% [IC] 18% 15%

2*SDCCH/8+ 42% [BC] 30% [AC,BC] 25% [AC,IC] 21% [IC]


SDCCH/4

3*SDCCH/8 43% 34% [BC] 28% [AC,BC]


EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 13 GSM Advanced Cell Planning
Appendix D, max SDCCH / TCH ratio
Half Rate Penetration: 5% Half Rate Penetration: 10%
No Cell Broadcast No Cell Broadcast

SDCCH Number of TRXs SDCCH Number of TRXs


configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 117% 33% 17% 12% SDCCH/4 117% 30% [AC,IC] 17% 12%
[AC,IC,BC] [AC,IC,BC] [AC,IC,BC]

SDCCH/8 242% 75% 38% 27% [AC,IC] 20% 16% 13% SDCCH/8 242% 68% [BC] 38% 27% [AC,IC] 19% 15% 13%
[AC,IC,BC] [AC,IC,BC]

SDCCH/8+SDCCH/4 59% 43% [BC] 30% [AC,IC] 24% [AC,IC] 20%


SDCCH/8+SDCCH/4 59% 43% [BC] 31% [AC,IC] 25% [AC,IC] 20%
2*SDCCH/8 58% 42% [BC] 34% [BC] 27% [AC,IC]
2*SDCCH/8 58% 43% [BC] 34% [BC] 29% [AC,IC]
2*SDCCH/8+ 43% 35% [BC]
2*SDCCH/8+ 44% 36% [BC] SDCCH/4
SDCCH/4
3*SDCCH/8 55% 43%
3*SDCCH/8 56% 45%

Half Rate Penetration: 5% Half Rate Penetration: 10%


Cell Broadcast used Cell Broadcast used

Number of TRXs SDCCH Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 83% 24% [AC,IC] 12% 9% SDCCH/4 83% 22% [IC] 12% 8%
[AC,IC,BC] [AC,IC,BC]

SDCCH/8 208% 65% [BC] 33% 23% [IC] 17% 14% 11% SDCCH/8 208% 59% [AC,BC] 33% 23% [IC] 16% 13% 11%
[AC,IC,BC]
[AC,IC,BC]
SDCCH/8+SDCCH/4 54% 39% [AC,BC] 27% [AC,IC] 22% [IC] 18%
SDCCH/8+SDCCH/4 54% 39% [AC,BC] 28% [AC,IC] 22% [IC] 19%
2*SDCCH/8 54% 39% [BC] 31% [AC,BC] 25% [AC,IC]
2*SDCCH/8 54% 40% [BC] 32% [AC,BC] 26% [AC,IC]
2*SDCCH/8+ 41% 33% [BC]
2*SDCCH/8+ 42% 34% [BC] SDCCH/4
SDCCH/4
3*SDCCH/8 52% 41%
3*SDCCH/8 54% 43%
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 14 GSM Advanced Cell Planning
Appendix D, max SDCCH / TCH ratio
Half Rate Penetration: 15% Half Rate Penetration: 20%
Cell Broadcast used Cell Broadcast used

Number of TRXs SDCCH Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 90% 30% [AC,IC] 16% 12% SDCCH/4 90% 30% 16% 11%
[AC,IC,BC] [AC,IC,BC] [AC,IC,BC]

SDCCH/8 187% 68% [BC] 36% 26% [AC,IC] 18% 15% 12% SDCCH/8 187% 68% 36% 25% [AC,IC] 18% 14% 12%
[AC,IC,BC] [AC,IC,BC]

SDCCH/8+SDCCH/4 57% 41% [BC] 29% [AC,IC] 23% [IC] 19% SDCCH/8+SDCCH/4 57% 39% [BC] 28% [AC,IC] 22% [IC] 19%

2*SDCCH/8 56% 41% [BC] 33% [AC,BC] 27% [AC,IC] 2*SDCCH/8 53% 39% [BC] 32% [AC,BC] 26% [AC,IC]

2*SDCCH/8+ 42% 34% [BC] 2*SDCCH/8+ 41% 33% [BC]


SDCCH/4 SDCCH/4

3*SDCCH/8 54% 43% 3*SDCCH/8 54% 42%

Half Rate Penetration: 15% Half Rate Penetration: 20%


Cell Broadcast used Cell Broadcast used

Number of TRXs SDCCH Number of TRXs


SDCCH
configuration configuration
1 2 3 4 5 6 7 1 2 3 4 5 6 7

SDCCH/4 65% 22% [IC] 12% 8% SDCCH/4 65% 22% [IC] 12% 8%
[AC,IC,BC] [AC,IC,BC]

SDCCH/8 161% 59% [AC,BC] 31% [AC,IC] 22% [IC] 15% 12% 10%
SDCCH/8 161% 59% [AC,BC] 31% [AC,IC] 22% [IC] 16% 13% 11%
SDCCH/8+SDCCH/4 52% [BC] 36% [AC,BC] 26% [AC,IC] 20% [IC] 17%
SDCCH/8+SDCCH/4 52% [BC] 37% [AC,BC] 26% [AC,IC] 21% [IC] 18%
2*SDCCH/8 50% 37% [BC] 30% [AC,BC] 24% [IC]
2*SDCCH/8 52% 38% [BC] 30% [AC,BC] 25% [AC,IC]
2*SDCCH/8+ 39% 32% [AC,BC]
2*SDCCH/8+ 40% 32% [BC] SDCCH/4
SDCCH/4
3*SDCCH/8 50% 40%
3*SDCCH/8 51% 41%
EN/FAD 109 0015

038 13 - LZU 108 881 Rev B Figure 3 - 15 GSM Advanced Cell Planning
Appendix D, max SDCCH / TCH ratio
Half Rate Penetration: 25%
Cell Broadcast used

SDCCH Number of TRXs


configuration
1 2 3 4 5 6 7

SDCCH/4 90% 27% [AC,IC] 16% 11%


[AC,IC,BC]

SDCCH/8 187% 62% [BC] 34% 24% [AC,IC] 17% 14% 12%
[AC,IC,BC]

SDCCH/8+SDCCH/4 52% 38% [BC] 27% [AC,IC] 22% [IC] 18%

2*SDCCH/8 51% 38% [BC] 30% [AC,BC] 25% [AC,IC]

2*SDCCH/8+ 39% 32% [BC]


SDCCH/4

3*SDCCH/8 51% 41%

Half Rate Penetration: 25%


Cell Broadcast used

SDCCH Number of TRXs


configuration
1 2 3 4 5 6 7

SDCCH/4 65% 20% [IC] 11% 8%


[AC,IC,BC]

SDCCH/8 161% 54% [AC,BC] 29% [AC,IC] 21% [IC] 15% 12% 10%

SDCCH/8+SDCCH/4 49% [BC] 34% [AC,BC] 25% [AC,IC] 20% 17%

2*SDCCH/8 48% 36% [BC] 28% [AC,BC] 23% [IC]

2*SDCCH/8+ 37% [BC] 31% [AC,BC]


SDCCH/4
EN/FAD 109 0015

3*SDCCH/8 49% 39%

038 13 - LZU 108 881 Rev B Figure 3 - 16 GSM Advanced Cell Planning

S-ar putea să vă placă și