Project
Location
- Standard
Penetration Test
(SPT) will be
conducted in
borehole for Soil
and weakly
cemented rock
formation (strata)
METHODOLOGY
Water Preassure Test (Lugeon Test)
SNI 2411-2008 - Water Pressure Permeability Test in the Field
- Water Preassure Test will be
conducted every 5 m
section in rock formation,
using single packer –
downstage method.
Atterberg Limit
Grain Size Distribution ASTM – D422
Spesific Gravity ASTM – D854
Unit Weight ASTM – D1556
Chemical Analysis of Water, Soil, and rock aggregates ASTM and BS
METHODOLOGY
Seismic Refraction Survey
- Seismic Refraction Survey will be conducted using OYO Mc-Seis SX24 XP,
using Turbo Hammer as a Seismic source
METHODOLOGY
Seismic Refraction Survey
The seismic refraction applied for investigated area is seismic profiling
Reciprocal Method. Hawkins (1961) method was modified by Hunting
Geology and Geophysics. This method is based on Laby and Edge’s Work
(1931), which is also known as the ABC method. The method is quite similar
with Hagiwara and Matsuda method. Each spread consists of 24
geophones and five to eight shots per run. The geophones are 5 m space
each for continuous study at proposed line. The total length per run of
seismic spread is 110 m for 2 spread and more (overlap 2 geophones), to
one spread 115 m length per run.