ABSTRACT An Affordable Intelligent Insulin Infusion System have the ability to


predict the amount of bolus to be injected to the body , in this case it is
insulin which would be very helpful in case of the divyang and busy
scheduled individuals , for the patients .
SECTOR Bio-Technology
STAGE Design, and early growth stage .
DIABETES: TOP 10 COUNTRIES
WORLD SCENARIO
2017 2030
Country Persons Country Persons
(millions) (millions)
1. India 61.7 India 90.4
2. China 38.8 China 52.3
3. USA 29.7 USA 40.3
4. Indonesia 12.4 Indonesia 18.3
5. Japan 6.8 Pakistan 13.9
6. Pakistan 6.2 Brazil 11.3
7. Russia 6.6 Bangladesh 11.1
8. Brazil 4.6 Japan 8.9
9. Italy 4.3 Philippines 7.8
10. Bangladesh 4.2 Egypt 6.7
WHO Report, Diabetes Care, 2017
Management and Advisory team

– Dr. Bhaskar Bhowmick. Kaushal Kumar Bhagat, Ph.D.


– Rajendra Mishra School of Engineering
Assistant Professor
Entrepreneurship.
Centre for Educational Technology,
– http://www.see.iitkgp.ac.in/
Indian Institute of Technology, Kharagpur
– Indian Institute of Technology Kharagpur.
India-721302
– Pin. 721302. India.
– Telefax (Off): 03222- 282415 Call:+91-9647931583
– Cell: 9088505496/ 8371959994
– e-mail: bhaskar@see.iitkgp.ac.in e-mail: kkntnu@cet.iitkgp.ac.in
– / bhowmickb@gmail.com
– Rajeev Ranjan

– Founder, Right Brain Mapping

– Web :http://rbrainmapping.com

– Cell: +91 – 9910194934/ 8920385593

– e-mail: rajeev.catchme@gmail.com

– / info@rbrainmapping.com

Prabhas Raj Panigrahi Project Lead & Coordinator , RBM


Dr. B. Sambi Reddy & Mr. Swagat Ku Samantaray Supervisor Associate Prof. & Assistant
professor NIST, Berhampur Orissa
Existing Products

 Continuous glucose monitoring


 Weak alarming system
system mandatory.
 Must use linked meter to
perform bolus calculations.  Data from pump/CGM not
downloadable to any program other
 cannot enter BG manually
than Carelink & Carelink Pro.
 No data storage system
 Insulin-on-board only deducted from
correction boluses.
Cost -: £3000
Cost -: $7,350
WORKING OF INSULIN INFUSION SYSTEM

INSULIN DELIVERY
CONTROLER INSULIN INFUSION SYSTEM
COMMANDS
SYSTEM
INSULIN

B
G
L

GLUCOSE MONITORING
FEEDBACK SYSTEM
INSULIN RESERVOIR SIFT PISTON

ACTUATOR

CONTROLLER

INTERFACING UNIT POWER SOURCE


FRONT VIEW REAR VIEW
Dimension of Device(in mm)
Needle Hub

Reservoir Hub

Emergency Detachable Unit

S-ar putea să vă placă și