Documente Academic
Documente Profesional
Documente Cultură
F F F F
2 2 2 2
4 4 4 4
C C C C
C C C C
R R R R
0 0 0 0
1 1 1 1
96 channel 2 degree +
96 channel 2 degree + 2xCD-AD 1:9
2xCD-AD 1:4 and 1:9
-50% x20
Power [Watt]
Capacity [Tbps]
80x10G terminal 80x10G terminal
based on 10G based on 200G
10G 100G 150G 200G 10G 100G 150G 200G
Leader in flexibility C and CD – up to CDC The right solution for each scenario
Maximum service agility Minimize investment
WSS WSS WSS WSS WSS WSS WSS WSS WSS WSS WSS WSS
Add/drop structure Client Port Add/drop structure Client Port Add/drop structure Client Port
Attachments Attachments Attachments
Ch.27
Ch.35 Ch.7 Ch.7 Ch.7
Ch.10
• Transponder can be remotely tuned to any Same wavelength can be dropped from N
Transponder can be remotely tuned to direction. directions via one a/d tree eliminating the
any wavelength. • Each wavelength can be dropped only once wavelength contention.
per a/d tree.
50 GHz
50 GHz
100Gb
100Gb
50 GHz
100Gb
2x200Gb
100 GHz
4x100Gb
150 GHz
1x400Gb
75 GHz
High capacity long-haul DWDM
transmission
Flexi-grid Efficient bandwidth assignment on
optical layer
Optimize reach versus spectral density
1-G002L20I
I01T100G-2/
I01T100G-2/
1-G002L20I
CCEP
I20C10G-1
I20C10G-1
Power supply unit
CQPS
CQPS
CQPS
OK FAULT
INFO ACT
ALARMS
ALARMS
EQUIP
COM
MAJ MAJ
LINE LINE
MIN MIN
C1 TLUA F KO TLUA F KO OK FAULT
TLUA F KO OK FAULT
TX TX TX
2 eniL 1 eniL
01 02 01 02 UBAT1 UBAT2
RX RX RX 2 eniL 1 eniL
UBAT3 UBAT4
C2 1
LINE
Q ILAN1 USER1
xT
03 04 03 04
FAULT FAULT XT XT
1 eniL
1 eniL
xR
C3 OK OK XR XR
FAULT
OK 2
05 06 05 06
SCN
C4 LINE LINE XT XT
2 eniL
4PFC
2 eniL
xT
XR XR
xR
07 08 07 08
C5 LINE CLIENT CLIENT
CLIENT 3
1
2 017
4PFC
xT
3
C6 4 09 10 09 10 016
xR
5
6
7
CCEP
8 4
C7 9
10 11 12 11 12
CLIENT CLIENT
4PFC
xT
xR
FAULT
C8 OK
13 14 13 14
Tx
CRIT CRIT
ALARMS
ALARMS
EQUIP
COM
MAJ MAJ
C9
15 16 15 16 MIN MIN
Rx
Rx
UBAT1 UBAT2
UBAT3 UBAT4
C10
17 18 17 18
Q ILAN1 USER1
19 20 19 20
Fiber routing guides
SCN
CCEP-3 / CCSP-3
CCEP-3 / CCxP-2 CCSP
Main functions of the Controller
CCSP-3 CTIF-1 Cards: CCMP-2 Controller CCEP-2
redundancy (Rel. 5.30)
• CCEP-3: CTIF-1 card: • CCMP-2: CCSP-1:
• Fault Management NE and main shelf
CRCB-1 Carrier Board
One sub-slot in • Telemetry Extension
• Performance
CRCB-1 Management
carrier board functions controller card shelf controller
• EOW Interface without TIF/Alarm card.
• Main-shelfManagement
Configuration controller
interfaces; 2 x CCEP-3 cards
card
• Security Management necessary for or
2 x CCSP-3 cards
NE and main shelf GMPLS
• Equipment Management
controller card
• CCEP-2:
• without TIF/Alarm
Communication Management
interfaces; NE and main shelf
• Software Management 2-slot controller
GMPLS supported
• Real Time Management • Increased
card with TIF/Alarm
node and GMPLS control plane
interfaces;
• CCSP-3: reliability
• Alarm Management necessary for
Sub-shelf controller • Two controllers equipped in parallel
GMPLS
card One active, one in protection mode
TIF: Telemetry Interface EOW: Engineering Order Wire Interface NE: Network Element
2.5 Gbit/s
MCP4-2/F 10 Gbit/s 96 /128 channels FlexiGrid Power Monitor
4 40 Gbit/s
(Release 5.40) card
100 Gbit/s
2.5 Gbit/s
10 Gbit/s 96 channels (within 50 GHz grid)
MCP4-2 4 40 Gbit/s monitoring (per port)
100 Gbit/s
2.5 Gbit/s
10 Gbit/s 80 channels (within 50 GHz grid)
MCP4-1 4
40 Gbit/s monitoring (per port)
100 Gbit/s
For
2.5 Gbit/s 40 channels (within 100 GHz grid)
legacy
MCP404-1 4 10 Gbit/s monitoring
40/80
40 Gbit/s (per port)
channels
…
Line side Client side
…
Line side Client side
Different types of amplifier cards well suited for various network scenarios
ONN ONN
OLR
9- 18dB flat
LASBC-1 card Short spans Booster amplifier No No 1- 25dB
17 dBm
OSC External
Monitor:
filter
OSA or
OTDR
Int. Mon
LAMIC-2/DCM and
LAMIC-1 and LAMPC-1 card
LAMICH-2/DCM card
• Very long spans • Very Long spans with • Very Long spans
enhanced OSC
• Booster amplifier • Inline amplifier
• Booster amplifier
• Booster amplifier • Interstage access
• Interstage access
• External pump supported • External pump supported
• External pump supported
• Transmitter OSC capabilities • Reciver and transmitter OSC
• Transmitter OSC capabilities capabilities
PRC-x card
Raman Pump Amplifier Card
Line
INPUT WSS
Card Variants:
RPump
• PRC-1/96 Monitor
OSC OSC EDFA Variable EDFA
Line Monitor filter Stage 1 optical Stage 2
• PRC-2 Monitor attenuator
Logic Unit
• PRC-3/FB Int. Mon
Controller
• PRC-4/FB
PRC-3/FB card
Raman Pump Amplifier Card
Line
WSS OUTPUT
RPump
Monitor
EDFA Variable EDFA OSC OSC TXr
Stage 1 optical Line
Stage 2 filter
attenuator Monitor
Logic Unit
Int. Mon
Controller
…
Line side Client side
MCS MCS
• 4 slot card
• Bidi flexi-grid add/drop card based on Multicast Switch
− All channels (going to that MCS) from each direction go to each port
− Selector switch sends all channels from only one direction to the add/drop port
− Coherent receiver then selects the appropriate channel
• Supports up to 8 directions and 16 interface cards
• Integrated add/drop amplification
• Flexi-grid ready HW
LAx LAx
WSS WSS
West F20MDR96 F20MDR96 East (Trunk
(Trunk 1) 2)
WSS WSS
LAx LAx
Transponder
Transponder
Transponder
Transponder
---up to 19 transponders---
Colorless termination
---up to 19 transponders---
Colorless termination
F09MDR9
F09MDR9
LAMPBC-
LAMPBC-
CCMP-2
MCP4-2
1/DCM
1/DCM
6-2/F
6-2/F
P- IN P- IN
COM
MAJOR
OUT7 OUT7
P- MonS IN7 P- MonS IN7
MINOR
o 7 o 7 CRITICAL
Flexi-grid Colorless ring node
ALARMS
P- P-
EQUIP
MonSt MonSt
OUT6 OUT6
MAJOR
P-To ISD IN6 P-To ISD IN6 MINOR
P- ISD
6 P- ISD
6 INFO
From From
OUT5 OUT5
IN5 IN5
B- OUT 5 B- OUT 5
TAP1
MonP1 B- IN OUT4
B- IN OUT4
IN4 IN4 EOW
MonS 4 MonS 4
B- o B- o
TAP2 OUT3 OUT3
MonP2 IN3 IN3
3 3
BOOSTER BOOSTER User2
OUT2 OUT2
TAP3
IN2 IN2 User1
2 2
MonP3
OUT1 OUT1 ILAN2
IN1 IN1
UBAT 2
1 1
TAP4 ILAN1
TX- OUT TX- OUT
MonP4
RX- IN RX- IN
10 10 Q
- -
UBAT1
IN IN
QF
AUX AUX
11 11
TX- MON TX- MON
RX- MON RX- MON
12 12
flatpack shelf
Compact flexi-grid Colorless MD-ROADM
FAN ALARM
• Compact terminal for up to 20 channels in
F20MDR9
LAMPBC-
CCMP-2
MCP4-2
1/DCM
6-2/F
1 2
2
1 1 10 0 19
RX-IN
FAULT
FAULT
FAULT FAULT
4 13 OK
OK OK 12
OK 3
UBAT1
UBAT2
PREAMPLIFIER OUT2 OUT11 OUT20 UBAT3
P-
IN2 IN11 IN20
UBAT4
OUT
CRITCAL
ALARMS
P- IN
COM
OUT1 OUT10 OUT19 MAJOR
P- MonS
IN1 IN10 IN19 MINOR
o
CRITICAL
ALARMS
P-
EQUIP
MonSt
OUT9 OUT18 MAJOR
P-To ISD IN9 IN18 MINOR
Flexi-grid Colorless terminal
P- ISD INFO
From
TX- OUT OUT8 OUT17
RX- IN IN8 IN17
TAP1 B- OUT
MonP1 B- IN
TX- MON OUT7 OUT16 EOW
MonS RX- MON IN7 IN16
B- o
TAP2
MonP2 - - OUT6 OUT15
BOOSTER AUX- IN IN6 IN15 User2
TAP3 OUT5 OUT14 User1
IN5 IN14
MonP3
ILAN2
OUT4 OUT13
TAP4 IN4 IN13 ILAN1
MonP4
Q
single flatpack shelf
OUT3 OUT12
IN3 IN12
UBAT1
QF
FAN ALARM
Passive Filter Card Overview
Communication Interleaver
Filter Cards Slots VOA Channel
type function
F40-1/S or /O 2 No Unidirectional 40 No
F48MDP-1/S or /O 4 No Bidirectional 48 No
F40MDS-1/S or /O 1 No Bidirectional 40 No
F48MDS-1/S or /O 2 No Bidirectional 48 No
F04MDN 1 No Bidirectional 4 No
F04MDU 1 No Bidirectional 4 No
l1 l2 … l40 l1 l2 … l40
l1 l2 … l40 l1 l2 … l40
Multiplexer Card Demultiplexer Card Multiplexer Card Demultiplexer Card
F40-1/O F40V-1/O
F48MDP-1/S or /O F48MDV-1/S or /O
F48MDP-1/S F48MDV-1/S
F48MDP-1/O F48MDV-1/O
F40MDS-1/S or /O F40MDS-1/IS
O-In Tx-Out Rx-In O-Out
Tx-Mon Tx-Out Rx-Mon Rx-In
F40MDS-1/S
Interleaver De-Interleaver
l1 l2 … l40 l1 l2 … l40
Tx-In Rx-Out F40MDS-1/IS
l1 l2 … l40 l1 l2 …l40
Tx-In Rx-Out
F40MDS-1/S or O: F40MDS-1/IS:
40-channel Bidirectional multiplexing/demultiplexing for 40-channel Bidirectional multiplexing/demultiplexing for
100GHz Standard frequency grid or Offset frequency grid 100GHz Standard frequency grid and includes a 50/100 GHz
interleaver (multiplexing path) and de-interleaver
(demultiplexing path) to connect to the corresponding
F4xMDS-1/O card
F40MDS-1/S
F48MDS-1/S or /O F48MDS-1/IS
O-In Tx-Out Rx-In O-Out
Tx-Mon Tx-Out Rx-Mon Rx-In
F48MDS-1/S
Interleaver De-Interleaver
l1 l2 … l48 l1 l2 … l48
Tx-In Rx-Out F48MDS-1/IS
l1 l2 … l48 l1 l2 …l48
Tx-In Rx-Out
F48MDS-1/S or O: F48MDS-1/IS:
• 48-channel Bidirectional • 48-channel Bidirectional multiplexing/demultiplexing for
multiplexing/demultiplexing for 100GHz Standard 100GHz Standard frequency grid and includes a 50/100
frequency grid or Offset frequency grid GHz interleaver (multiplexing path) and de-interleaver
(demultiplexing path) to connect to the corresponding
• 2 slots
F4xMDS-1/O card
F48MDS-1/S • 2 slots
C02
C01 • 40 channels overall
(192.1 … 196.0 THz)
C05 C06
C07 C08
C09 C10
F16SB-1 (red)
• Bidirectional single slot card • Bidirectional single slot card • Bidirectional single slot card • Bidirectional single slot card
• Four channel fixed filter • One band filter and one • One band filter and two band • Four cascaded band filters
• Offered in ten different variants corresponding four channel filter filter
(sub-bands C1-C10) to cover
the entire 40 channel
wavelength plan
F16SB
F08SB
F04MDU
Band Filter
Channel Filter
Amplifier
• Transponder or Muxponder converts one or several client signals into optical DWDM
signal
• All data are transmitted with OTU (Optical Channel Transport Unit)
• All line interfaces can be used in Metro, Long-haul and Ultra long-haul networks
• Excellent span performance due to:
High dispersion tolerance
Forward Error Correction (FEC) and SUPER FEC
• Each transponder/Muxponder card supports optical channel protection
DWDM (DWDM)
(DWDM) XFP (DWDM) SFP SFP DWDM
XFP
XFP
(DWDM) SFP (DWDM)
(DWDM) XFP 4x DWDM DWDM SFP GFP-T
OTU2 XFP (DWDM) SFP ODU XFP Mapper
Framer (DWDM)
Cross SFP Add/Drop
and DWDM (DWDM) SFP Connect DWDM Switch
Mapper XFP XFP (DWDM)
SFP+ (DWDM) SFP SFP DWDM
XFP
DWDM (DWDM)
SFP+ XFP (DWDM) SFP
SFP
(DWDM) SFP
I10T100G
I01T100G-1/2
(DWDM) XFP
Line
(DWDM) XFP OTU4 Side
Framer
OTU4 Framer Line Side CFP CP-
and Mapper and
CP-QPSK Mapper QPS
K
(DWDM) XFP
(DWDM) XFP
(DWDM) XFP
(DWDM) CFP
I04TQ10G
I08AD10G
• Single slot card
• ODU0, ODU1, and ODUflex granularity switching
4 client interfaces
(switching capacity 80G)
2 line interfaces
8 x OTU1 or
• 7% EFEC on line side with 8 dB coding gain
(DWDM) SFP I08AD10G
8 x STM-16/OC-48 or • 1+1 uni- and bi-directional protection (Higher order
(DWDM) SFP
8 x STM-4/OC-12 or and Lower order SNC/I protection, and automatic
8 x STM-1/OC-3 or (DWDM) SFP
DWDM OTU2 protection switching with G.709 protocol)
8x GE opt./el. or
• OTU2
(DWDM) SFP ODU XFP
8 x FE opt./el. or Cross • GCC0 support on client and line side
(DWDM) SFP Connect DWDM
4 x 4G FC/Ficon or
(DWDM) SFP
XFP • Drop and continue, drop to multiple clients,
8 x 2G FC/Ficon or multicast add to both lines
(DWDM) SFP
8 x 1G FC/Ficon or
4 x 3G HD SDI or (DWDM) SFP • Delay measurement for OTU1 client I/Fs and OTU2
8 x 1.5G HD SDI or line I/Fs
8 x anyrate or • TCM support: 6 out of 6 layers
or any mix
• Loopbacks for testing purposes
Local Cross Connect ODU Cross Connect Line and client ports
client client
client client
client client
client line client line
client client line
line
client client
client client
client client
•
Line Traffic ODU Cross Connect Express Line Traffic
client client
client client
client client
client line line
client
client line client line
client client
client client
client client
I05AD10G
• Add/Drop Multiplexer (ADM) with dual Muxponder
application
5 Client interfaces: 2 line interfaces • grey/C/DWDM XFP based line ports
FE, GE,
(DWDM)
SFP DWDM • grey/C/DWDM SFP based client ports for the
XFP OTU2
STM-1/OC-3, (DWDM) following client interface types
SFP GFP-T
STM-4/OC-12, (DWDM) Mapper • up to 5x FE (100BaseT), 5x GE (1000Base-X/-T),
SFP Add/Drop
FC-4G, Switch STM-1/OC-3, STM-4/OC-12,
(DWDM)
STM-16/OC-48, SFP DWDM
XFP OTU2 • up to 4x FC-4G / FICON 4G, STM-16/OC-48
anyrate
•
(DWDM)
SFP mixed client interfaces
• • Anyrate clients (100 Mbit/s – 3.4 Gbit/s, free mix
with other clients)*
• Direct optical connection of I05AD10G to I01T10G,
Application: I04TQ10G and I04T40G
• Cost effective add/drop and drop/continue for Ethernet, • 1 slot card, Total capacity per OTU2: 9xGE or 2x
SDH/SONET, and SAN services 4G FC
• Cost effective video multicast in DWDM equipment optimized • GFP Channel Protection via second line port
service delivery by IP router off-loading (CAPEX/OPEX) • Drop & Continue / Broadcast Function
100M-3.4G
3G HD SDI
any- rate
STM-256
1.5G HD
STM-16
STM-64
FC-10G
FC-16G
100 GE
STM-1
STM-4
FC-1G
FC-2G
FC-4G
FC-8G
10 GE
40 GE
OTU1
OTU2
OTU3
OTU4
1 GE
SDI
FE
I08T10G X X X
I04TQ10G X X X X X
I05AD10G X X X X X X
I08AD10G X X X X X X X X X X X X
I01T100G-1/2 (/CQP) X X
I10T100G-1/2 (/CQP) X X X
I04T100G-2 (/CQP) X X X X X X
I04C100G-1 X X
I20C10G-1 X X X X X X
…
DWDM
…
CWDM CWDM
… … …
…
…
DC
WSS WSS
…
…
WSS WSS
DC
…
… …
…
Fixed OADM and multi-degree junction ROADM/MD-ROADM: 40/80/96ch, 50/100GHz grid and
40/80ch, 50/100GHz, wavelength routing by patch cord, FlexiGrid
extendable up to nodal degree six/eight SW reconfigurable node, up to 16 degrees
Band filter
Interleaver
Channel filter
© 2016 Coriant. All rights reserved. Company Confidential. Splitter/coupler
Amplifier
Thank You.