VICAT Apparatus
Weight balance
Plunger with 10mm diameter and
50mm length
Spatula
Glass plate trowel
Stop watch
The temperature of the air in
the vicinity should be between
20-27.5 °C. The temperature of
Temperature & Humidity the mixing water should be
23±2 °C.The relative humidity
of the laboratory should not be
less than 50%
specification
specifications are mentioned
below.
• The cement paste must be properly mixed and placed in the test
specimen within a maximum time of 4±1/4 min from the instant
when cement and water were initially brought in contact
Procedure
• Mix 650gm of cement with a measured quantity of water and make a cement
paste as per the standard procedure.
• Put the cement paste in the ring of the vicat apparatus and remove the excess
paste with the help of a trowel. Center the paste confined in the ring, resting
on the plate, under the plunger rod and bring the plunger end in contact with
the surface of the paste.
• Pull the hydraulic jack so that some amount of energy is stored in it and when
released that stored energy is transferred to the cement paste.This must not
exceed 30 s after completion of mixing.
• The apparatus shall be free of all vibrations during the test. The paste of
normal consistency is achieved when the rod settles to a point such that it is 4-
7mm above the bottom surface in 30 s after being released.
• Make trial pastes with varying percentages of water until the normal
consistency is obtained. Make each trial with fresh cement.
Observations & Results
Trial
Weight of Moisture
Sr. # Cement Content Weight/Volume of Water Temperature Mixing Time Scale Reading