Sunteți pe pagina 1din 39

Electrical Safety/

Lock out Tag out

1
Should we be concerned?
-Statistics
Death/1 Lac Employees
Electricians
Structrual Metal Workers
Laborers
Electrical Power Installer
Roofers
Painters
Supervisior
Plumbers & pipe fitters.
Carpenter
Concrete finishers
Brickmasons & Stonemason
Tile Setters
Drywall Installer
Carpet Installer

0 1 2 3 4 5 6 7

2
Fatalities Among U.S.Construction worker Survey
Electrical Hazards
Accidents do not just happen, they are caused. Most electrical accidents result from one
of the following three factors or any combinations
• Unsafe equipment or installation,
• Unsafe environment, or
• Unsafe work practices.
The following are specific electrical hazards the worker is exposed to in
the work place.

Hazards of Electricity
Shock
Arc
Blast
3
Hazard Classification
PRIMARY SECONDARY

ELECTRIC SHOCK FALLING FROM HEIGHT

ELECTRIC FIRE AND


DROPPING OF TOOLS AND OBJECTS
EXPLOSION

ELECTRIC FLASH
RELEASE OF TOXIC GAS AND UV RAY
ELECTRIC BURNS

Avoid Unsafe Practices High Voltage Precautions

4
Should we be concerned?
-Human susceptibility
BODY AREA RESISTANCE IN OHMS

DRY SKIN 1,00,000 TO 6,00,000


OHMS

WET SKIN 1000 OHMS

INTERNAL BODY

HAND TO FOOT 400 TO 600 OHMS

EAR TO EAR (ABOUT) 100 OHMS

5
Severity of Electrical Shock
• The severity of shock depends on the personal sensitivity and varies from person to
person.
• It also depends on age, sex, heart condition etc.
• Even for the same person, electrical shock depends on many factors. The severity of
electrical shock is the function of the current (mA) and the time for which it flows
through the body. 50 mA current can flow for 200 ms through the body without much
danger, whereas 500 mA current even for 50 ms could be fatal.
• It depends on rate of flow of current, path of current through the body and duration of
time the body is in the circuit.
Reasons for Electric Shock
1. Victim touches bare live conductor.
2. Victim touches poorly insulated conductor.
3. OC / SC due to equipment failure.
4. Static electricity.
5. Lightning.

6
Effect on BODY
Nervous system effects
 One can stop breathing at 30 mA alternating current at 50Hz
 Heart fibrillation can occur at 75 to 100 mA at 50 Hz.
 Fibrillation means the heart is twitching and there is no blood flow to the
body.
 The heart can be damaged because it is in the path of most common
pathways:
 Hand to hand
 Hand to foot

7
Current Effect
Injury depends on amplitude & time. When 50 Hz current passes through
human body, from left hand to both legs & to the earth, for one second, it has
different effects at different values, as tabulated below;
Current (mA) Effect
• Up to 1 No sensation
• 1 to 8 Sensation there, but not painful
• 8 to 15 Painful shock, but muscular control still there.
• 15 to 20 Muscular control lost, resulting in sticking
• 20 to 50 Severe muscular contraction
• 50 to 200 Ventricular fibrillation and possible death
• > 200 Severe burns, severe ventricular fibrillation resulting in death.

9
Fatal – Due to contact with open electric circuit

Brief Description:

The deceased was engaged in repairing of grinding machine. After checking of


grinding machine he changed the carbon brushes, he plugged in the machine to
nearby distribution panel near the repair platform where he was sitting. After
plugging, he switched ON the supply and at the same time, grinding machine slipped
from his hands. While trying to hold the machine, his hands touched the open electric
circuit and he got electrocuted.

10
ELECTRICAL SHOCK INCIDENT IN PLANT

Two persons were engaged in preheating process,


Heating coils of two different pipe joints were
connected from one transformer e.g heater-1 &
heater-2. Before going for lunch, deceased instructed
to his helper to switch off the power of heater
number-2 but mistakenly, he switched off the power
of heater number-1 & went for the lunch. Heater
number-2 needer to be shifted to another place for
heat treatment of other pipes. After lunch, the
deceased himself removed the live wire from heater
number-2 & tried to connect it on the other pipe.
While doing so live wire touched to his body & got
electrocuted. Due to elctric shock, his body thrown
away & disconnected from the live supply. At the
same time, workers working nearby saw him,
immediately called their vehicle & shifted him
hospital where he succumbed to his injury.

11
LTI – Due to contact with HV Supply

Brief Description:

6.6 KV breaker panel inspection job was taken, after removal of the breaker, one of
the engineer was checking the chattering sound inside the breaker chamber, his left
hand accidently came in contact with the live part causing severe electric shock.

12
FATAL - Main Fan House, Waste gas fan Excitation Transformer.
Brief description:
Electrician of M/s. Prince Engg. and Electrician of M/s. Thompet received electrical
shock and burn injuries while working in Bus bar of main fan excitation Transformer.

13
Immediate cause:
 Direct Contact with Bus Bar of Excitation
Transformer which was not properly isolated.
 Inattention / Lack of Awareness of Hazards.

Root cause:
 Proper Work Permit procedure not followed
(Job was executed beyond the scope of the
Work Permit). 14
Prevention methods
• Proper Isolation
• Earthing & Grounding
• Insulation
• Protective devices - ELCB, RCCB
• Guarding
• Safe work practices. (SOP, PTW, PPE, etc.)

15
OUR STRATEGY….
• Safety should be build at design stage
• Pre-startup safety
• Clear HIRAC and SOP
• Pro active inspection
• PTW
• Maintenance as per OEM recommendation

16
SAFETY PRACTICES
In all electrical work, it is very necessary that certain elementary safety practices are
observed. It has been found that quite a large number of accidents occur due to the
neglect of these practices.
Exercise Care
 Place yourself in a safe and secure position to avoid slipping, stumbling or
moving backward against live conductors or apparatus.
 Do not rely for protection upon the care assumed to be exercised by others.
 Make a habit of being cautious.
 Be on the lookout for danger notice plates, danger flags, warning boards and
signals, etc.
 Warn others when they seem to be in danger near live conductors or apparatus.
PERSONAL APPAREL
 While working on live conductors, do not roll up sleeves as dry cloth gives
some protection against shocks.
 Do not wear shoes with nailed soles. Shoes should have sewn soles, or
preferably rubber soles.
17
SAFETY PRACTICES
While welding wear goggles, safety glasses or any other eye protection as
instructed by the person-in-charge depending upon the type of work handled.
Do not wear suspenders and arm bands with metal buckles or other metal parts.
These might come in close proximity to live parts and cause serious, if not fatal,
injury.

TREAT EVERYTHING AS LIVE


 Treat all electrical conductors and apparatus always as live and consequently
dangerous to human life, unless it is positively known to be dead and properly
earthed and take precautions accordingly.

THINK BEFORE YOU ACT


 Think carefully before you act. Make sure you are right. Watch out for the
other man and make sure he is right.
 Never speak to any person working upon live mains or apparatus, unless the
person doing the work is aware of your presence.

18
SAFETY PRACTICES
DANGEROUS VOLTAGES
 All voltages are dangerous. It shall be borne in mind that even low voltage
shock may be fatal.
 Every person-in-charge of work on any mains or apparatus shall ensure himself
that the same is free from dangerous leakage or induction and has been
effectively earthed locally before permitting men to work upon it.
DANGEROUS AREAS
 When working in areas which contain or may contain live mains and apparatus,
fix danger notice plates, barriers, rails or other guarding arrangement for the
working area.

CAUTION
AREA IN FRONT OF THIS
ELECTRICAL PANEL MUST BE
KEPT CLEAR FOR 36 INCHES
OSHA - NEC REGULATIONS

19
SAFETY PRACTICES
WARNING BOARDS
 Warning boards shall be placed by the person-in-charge on all switchgear before
men are permitted to work and should only be removed by the person who has
placed them.
VISITORS AND UNAUTHORIZED PERSONS
 Visitors and unauthorized persons shall not be allowed to proceed in the vicinity
of live mains and apparatus, unless accompained by an authorized person whose
responsibility it shall be to ensure that his instructions regarding safety are
strictly complied with.
WORKING IN DAMP SITUATIONS
 Extra precautions should be taken when working in abnormally damp area.

20
SAFETY PRACTICES
PORTABLE ELECTRICAL APPARATUS
 All portable electrical apparatus shall be regularly examined, tested and
maintained to ensure that the apparatus and leads are in good order.
 Ensure that all portable appliances are provided with 3-pin plug and socket
connections and that the metal work of the apparatus is effectively earthed.
 All loose wiring, such as flexible cables for portable lamps, tools and trailing
cables and other portable and transportable apparatus, shall be tested regularly
at frequent intervals to ensure safety.

Damaged/Broken case

Ground prong missing on


three-prong plugs.
Some tools are double
insulated and won’t have
a ground prong. That’s OK.
Damaged Cord – outer
sheath broken
21
Guide Lines for Using
There Portable
are more chances of Devices
Accidents taking place while working with Portable
equipments. (single phase 230V AC, 110V/220V DC , three phase 415V AC).
Use of portable electrical equipment or any temporary electrical installation,
electrical supply shall be approved by the authorized electrical engineer.
Each Portable Equipment should have an Identification Tag, Electrical Certification
date and Next Certification due date pasted on it.
In addition every time before use, the healthiness of the items like Cable, Gland,
Earthing etc. shall be checked once again.
All portable appliances shall have a preventive maintenance schedule and checklist.
Duly tested ELCB of proper rating and sensitivity shall be used on the incoming
side of supply so as to safeguard the operating personnel against electrical shock.
No interlock or protection shall be bypassed or made ineffective.
Preferably there shall not be any joint in the flexible PVC cable, where joint
cannot be avoided due to large length (>100 meters) required joint shall be properly
insulated.
Only 3 pin plug of approved quality shall be used for tapping supply from the
switch socket.
22
ELECTRICAL EQUIPMENT
INSTALLATION
Earthing :- Earthing means Equipment earthing and System earthing.
• Earthing system is designed to the maximum fault current based on equipment
rating.
• Manufacturer provide two earthing points.
• The design of Earthing is considered to take care of future expansions.
• Earth strips are connected to “ Earth Pits “
• For the system earthing, neutral point is connected to earth pit either directly or
through a resistance.

23
ELECTRICAL FIRE
Electricity heat the media through which it
passes.
The electrical equipment heats up during use and
more so in case of heater, bulbs, faulty
equipment, loose connection.
If the heat generated by the equipment is more
than heat dissipated in the area leads to failure of
the equipment/ insulation / fire.
In 30 % of Industrial fires - the Electricity is
involved in one way or other.
Electrical fire = A defect + A medium that can
24
ELECTRICAL FIRE
Electrical Fires are due to …….
 Damage due to rodents, termites and pests
 Static Electricity
 Improper protection against mechanical damage

25
ELECTRICAL FIRE
Motors :-
The principal hazards of Motors are as under
• Insulation failure due to age, inherent defect, Moisture, overload, inadequate
ventilation or accumulation of dust.
• Sparking and arcing at commutators due to wear, dirt and faulty adjustments.
• Burning of armature coil or motor coils due to short circuit.
• Burning of cables due to insulation failure from persistent overload and short
circuit.
• Over heating, arcing and sparking at terminals due to improper connections.
• Mechanical breakdown which may have indirect effect causing fires.

26
ELECTRICAL FIRE
Transformers :-
Transformer fails because of following reasons
• Oil contaminated with moisture
• Loose internal connections
• Overheating of oil due to leaks
• Overloading
• Internal failure
Switch Gear Panels :-
Switchgear fire because of following reasons
• Loose internal connections
• Overloading
• Internal Mechanism failure
• Improper setting

27
ELECTRICAL FIRE
Electrical fires could be avoided by following precautions :-
Use good quality (ISI) wires/cables.
• Avoid joints in wiring - soldering and proper mechanical joints should be made if the
same cannot be avoided.
• Old wiring should be renewed after ageing.
• Fuses used for protection should be of adequate capacity. The ratings should not be
increased without ascertaining reason of fuse blowing.
• Fuse boards should be away from combustible materials like paper, oil, curtains etc.
• Avoid using stream of water, Wet blanket or stream of Soda-Acid Extinguisher on
live mains or equipments.
• Before fighting fire ensure all Electrical mains, equipment, neighbouring mains
switched - off.
• Treat all the cables, mains or equipments as live unless and until isolated positively.

28
ELECTRICAL FIRE
Control of Electrical Fires :-
Electrical fires are termed as Class-C / E fires
Hand appliances :-
 Use of Sand buckets
 Co2 or DCP type extinguishers
Fixed Installations :-
 Automatic DCP type
 Multityre system installation
 Halon / Co2 flooding installation

29
DISCHARGE ROD

30
ZEBRA CROSSING TO BUS
COUPLER/TIE FEEDER

31
ISOLATION CONDITION MENTIONED
ON FEEDER

32
ISOLATION CONDITION MENTIONED
ON FEEDER

33
ISOLATION/EMERGENCY OPERATION
CONDITION MENTIONED ON FEEDER

34
SLD & DIRECTION OF FLOW OF
CURRENT MENTIONED ON PANEL

35
INCOMER & BUSCOUPLER LOCATION
MARKED

36
What To Do:
Check For :-
• Pulse
If person's heart has stopped, start CPR
(Cardiopulmonary resuscitation), if you are
trained.
• Breathing
If person isn't breathing, begin mouth-to-mouth
resuscitation, if you are trained.
• Treat for shock
Keep person lying down.
If unconscious, put them on their side to let
fluids drain.
Don't move the person if neck or spine injuries
are possible.
Cover the person to maintain body heat

Stay with patient until help arrives


Inform medical personnel about patient conditions

37
Summary :-

Appliances and equipment should have the proper


label
Don’t overload electrical circuits

Make sure all electrical equipment is properly


grounded

Ensure power is off before working on electrical


devices

If you are not sure and something appears wrong,


call an Electrical Engineer / electrician / Electrical
Control Room

Never bypass fuses and protective devices

38
Thank you

39
LOTO PROVISION IN VCB

42

S-ar putea să vă placă și