DEVIATION
SET POINT SIGNAL OUTPUT
M.V
SIGNAL
CONTROLLER SIGNAL FINAL CONTROL
S.V ELEMENT
P.V CORRECTIVE
CONTROLLED VARIABLE SIGNAL
ACTION
MEASURING PROCESS
MEANS
AUTOMATIC PROCESS CONTROL
S.V.
FLOW INDICATING CONTROLLE.
FIC
P.V.
F.T.
M.V
PIPE LINE
F.E (ORIFICE PLATE) CONTROL FLOW OUT
FLOW IN
VALVE
Field transmitter
Junction Marshalling
Barrier 4 - 20 mAT
box rack
4 - 20 mA 4 - 20 mA O
4 - 20 mA 4 - 20 mA
S
Y
S
T
I/P Junction Marshalling
Barrier
box rack E
4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA M
3 - 15
PSI
Control
Valve
MODES OF OPERATION :
• MANUAL
• AUTO
• CASCADE
• SPC
• DDC
ENG. SUPERVISORY
OPERATOR COMPUTER
STATION STATION
GATEWAY UNIT
DATAHIGHWAY (OPTION)
(OPTION)
GATEWAY UNIT
CONTROL DAS
STATION
PLC
Data Highway
CRT CRT CRT CRT
Operator Station
Supervisory
Computer
DISTRIBUTED CONTROL SYSTEM
CONTROLLER DESIGN :
1. OVERVIEW DISPLAY
2. AREA DISPLAY
3. GROUP DISPLAY
Controllers
Process
HIERARCHY IN DCS
PROCESS :
Conversion
Raw Material Product
ELEMENTS IN A PROCESS :
• Flow
• Temperature
• Pressure
• Level
• Composition
What is a process
What are variables in a process
What are the effects of these variables on the process
How are these variables regulated.
PROCESS PARAMETERS
TRANSMISSION &
CONTROL
• Flow
• Temperature
• Pressure
• Level
• Composition
SAFETY
• Flammable Materials in Industrial Processes
• Spillage may give rise to an Exp..ATM.
• Precautions to Protect both Plant and Personnel
• The ‘ HAZARDOUS’ and ‘ SAFE’ Areas classification
• What is IS ? (INTRINSIC SAFETY)
Restricting the Electrical Energy available in
Hazardous Area circuits such that any sparks or Hot
Surfaces that may occur as a Result of Electrical faults
are too weak to cause Ignition
•To Limit the Energy supplied to the Hazardous
areas we use Interface BARRIERS between the Safe
area and the Hazardous Area.
AREA CLASSIFICATION
NORTH
DIVISION 1 DIVISION 2
AMERICA
CURRENT
FUSE LIMITOR
Data
Highway MTL3052
X 16 Isolator
MTL821 MTL825
transmitter receiver
MTL switch multiplexer system
GUS 01 GUS 02 GUS 03 GUS 04 GUS 05 GUS 06 GUS 07 GUS 08 GUS 09
NIM 11 NIM 12 HM 21 CG 22 AM 25 AM 26
The GUS is the primary TPS human interface. It provides a single window to
the entire system, whether the data is resident in one of the LCN modules or
in one of the devices in UCN or HIWAY.
Network configuration.
Building process database, custom graphics
System files of all types, load images, and other data required anytime
modules are reloaded or personalities are changed.
NIM
NIM
HPM’s dual 68040 platform offers a wide ranges of capabilities for present
and future process requirements.
It offers flexible I/O functions for both data monitoring and control .
24 V DC Junction Marshalling
Barrier 4 - 20 mAT
box rack
4 - 20 mA 4 - 20 mA O
4 - 20 mA 4 - 20 mA
S
Y
S
T
I/P Junction Marshalling
Barrier
box rack E
4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA M
3 - 15
PSI
Control Valve
m CH 1 H1 100 110 0 100 110 0
V
CH 2 TO SI CARD
MTL MTL
MUX MUX
1372B 1372B
CH 15
CH 16
.. CH 16