Documente Academic
Documente Profesional
Documente Cultură
à
DTC 2MW wind turbine was independently developed with intellectual property rights. It features modular
design, simple structure, easy maintenance, low cost. And it inherited the advantages of FD77/FD70 control
strategy, electrical system, yaw system, tower, frame ect. Innovative design was adopted on main shaft and hub.
It is efficient and can meet the diversified customer needs.
Technical Features
Adopts horizontal axis, three blades, pitch adjustment, double supports at gearbox, double ʹ fed asynchronous
generator.
Inherits FD77/FD70 advantages.
Independent blade electric ʹ driven pitch. Air brake via blade feathering plus rotor brake.
Three ʹ point ʹ support drive train. Vibration damper between gearbox and frame.
Variable speed constant frequency system. When the wind turbine is operating under rated speed, the system can
adjust generator rotor slip ratio to operate at the best tip speed ratio to output maximum power. When the
turbine is operating at rated speed, the system can control power output through pitching to realize constant
output.
Adopt optical fiber communication between the foot of tower and nacelle. And the electric system is powered by
separate supply and the anti ʹ interference is good.
Nacelle is human engineered and room is big enough for maintenance. And it is equipped with electric lifting
device.
Convertor adopts rotor circuit partial conversion technology. The generator adopts four ʹ pole double ʹ fed
asynchronous technology with slip ring.
Yaw system can determine the direction according to the signal provided by the vane.
Generator and converter uses air ʹ cooling technology with high cooling efficiency, small size, light weight, and
high degree of protection.
à
X
V FD93
IEC II b or IEC III a
2000KW
3m/s
11.0m/s
25.0m/s
52.5m/s (3 seconds)
Ambient Climate -20ü +40ü
Cold Climate -30ü +40ü
Ambient Climate -20ü +50ü (below -20ü not exceeding 9 days)
X
Cold Climate -45ü +50ü
ð
o 2000m
à
à
X
V FD82E
IEC I a
2000KW
3.5m/s
12.0m/s
25.0m/s
70m/s (3 seconds)
Ambient Climate -20ü +40ü
Cold Climate -30ü +40ü
Ambient Climate -20ü +50ü (below -20ü not exceeding 9 days)
X
Cold Climate -45ü +50ü
ð
o 2000m
à
à
à V
ððVX
!
"
!
V FD60
IEC II a
1000KW
3.5m/s
12.0m/s
26.0m/s
59.5m/s (3 seconds)
Ambient Climate -20ü +40ü
Cold Climate -30ü +40ü
Ambient Climate -20ü +50ü (below -20ü not exceeding 9 days)
X
Cold Climate -45ü +50ü
ð
o 2000m
|
·
Ú
!"
#!$%
$&
'
!(
) *+
'
!+%
#%%
' X
!
"
·
#
X
$
$
X % $
X %X %
$
&
#
'
#
Manufacturing
,
-.
Ú
)/*
01 )2 *
-
-
%%% 3
4
Manufacturing
, 5
6!
4
+%%%å
-.5
6!
, 7
-. -
3 0
4
%%%å
$%%
Wind Power
Division
Engineering Team
Xervice Telephone No. (24 hours):
Fax:
Email: