Balancing Training

Part 1

Typical Steps of field Balancing


Illustration with model 907
E-mail: sales@sendig.com, sendigbj@yahoo.com.cn Telephone: +8610 82895321 Fax: +8610 82895320 http://www.sendig.com

www.sendig.com

An Overview of the Steps


1. 2. 3. 4. 5.

Collecting Machine data


Preparing Instrument & Sensor

Balancing really required ?


Balancing possible ?

Procedure of balancing
2

www.sendig.com

Step 1 - Collecting Machine data

Understand the machine to be balanced as much as possible Collect machine data Take a photo of the machine

www.sendig.com

Sample: Machine to be balanced


Impeller Parameter: Diameter: 1400mm Thickness: 500mm
Bearing1 Bearing2

Blade Number: 12
Material:Fiberglass-Reinforced Plastics RPM: 1825 r/min

Impeller

Bearing Model: ?
Motor Parameter: Power: 75kW RPM: 1500 r/min

Motor

Others:
Belt transmission Spring base Manufacture: LG

Step 2 - Preparing Instrument & Sensors

Sendig-904/907 dual-channel data collector/analyser/balancer A notebook computer Sendig-MCM3 Analysis Software

www.sendig.com

Sensors & Cable connecting


Attach reflecting paper on shaft

www.sendig.com

Step 3 - Balancing really required ?


Use 904/907 to measure overall vibration values Compare with ISO Standard

2) Use Collector to measure vibration

1) Switch to Analyzer

www.sendig.com

Horizontal VELOCITY is the critical parameter

6: Point: Motor-1-Side-2-X Alarm-mode: Displacement Freq-Range: 500Hz Sensor:4.6 New Data Old Data ACC xxx / xxx m/s2 VEL 7.2 / 2.1 mm/s DISP 68 / 12 m ENV xx / xx m/s2

www.sendig.com

Comparison with ISO2372

Sample

Overall Value Measurement


Acc.
Peak ms-2

Vel.
RMS mm/s

Disp.
P_P um

Envelope
RMS ms-2

Hor. 88.81 Ver. 55.89

9.95 5.554

101.5 38.77

5.268 7.362

www.sendig.com

10

Sample
Not Permissible, Balancing really required

Measurement

9.95 mm/s

Step 4-1: Balancing possible? single peak spectrum ?


Use 904/907 to measure vibration spectrum Only single peak spectrum can go for balancing

2) Use Collector to measure vibration 3) Use C-Spect to see velocity spectrum


www.sendig.com

1) Switch to Analyzer

12

Sample of non-single peak spectrum- not suitable for Balancing

www.sendig.com

13

Sample of non-single peak spectrum- Better change bearing before balancing

www.sendig.com

14

Sample of single peak spectrum You can reduce the vibration by Balancing

www.sendig.com

15

Step 4-2: Balancing possible ? 90o phase difference ?

Use 904/907 to measure vibration phase difference between vertical and horizontal directions Only 90o phase difference can go for balancing

3) See if 90o phase difference exist?


1) switch to balancer and use 2-planes balancing procedure

2) Page down to Initial Measurement to measure vibration phase at X & Y


www.sendig.com 16

Sample

Sample of non-90o phase difference You cannot reduce the vibration by Balancing

Phase Measurement:
Velocity Amplitude Phase

Vertical:
Horizontal:

9.416
3.08

320
116
Phase difference not 90o

Since phase difference is not 90o nor closer to 90o ,this means the problem with the fan is something else other than unbalance.
www.sendig.com 17

Sample

Sample of nearly 90o phase difference You can reduce the vibration by Balancing

1. Phase stable
2. Phase Measurement:

Velocity
Vertical:

Amplitude
0.693

Phase
73

Horizontal:
?
www.sendig.com

1.569

150

Phase difference is 77o

18

Balancing Training

Part 2

Procedure of balancing

www.sendig.com

19

Different Kinds Of Imbalance


1-plane imbalance 2-plane imbalance

www.sendig.com

20

Characteristics Of Imbalance
1. The vibration frequency is mainly composed of RPM frequency. For each round the rotor turns, a

vibration is occurred.
2. The wave is an approximate sine wave. 3. There is a difference of 90o between the vertical

vibration phase and the horizontal one.


4. With RPM increasing, the vibration amplitude is increased
www.sendig.com 21

Basic Principle Of 1 Plane Balancing


1 select a plane to fix trial mass and a point to measure, draw scale of phase and sign of 0o phase

2 measure initial vibration A0(phase and amplitude)

3 fix a trial mass Q on the plane, measure vibration A1

4 calculate influence coefficients: A A0 phase RPM amplitude 1 Q P A0 5 calculate balancing mass P:


www.sendig.com

22

Illustration of 1 Plane Balancing

draw A0 & A1, calculate A1- A0 measure the angle between A1- A0 and A0

K P

turn Q a along the direction of , gain the correct location of balancing mass.
the weight of balancing mass is as the following : A
PQ
0

A1- A0 A1 A0 o
www.sendig.com

A1 A0
23

Method of Influence Coefficients

Method of influence coefficients is widely used, its step as the following (1 plane balancing as example):
1 measure initial vibration 2 fix a trial mass

3 measure the vibration with the trial mass


4 calculate the result of balancing mass
www.sendig.com 24

IF THE INFLUENCE COEFFICIENTS ARE KNOWN, THE STEP OF FIXING TRIAL MASS ARE IGNORED

The former steps are simplified as the following:

1) measure initial measurement 2) input influence coefficients 3) calculate the result of balancing mass

www.sendig.com

25

NOTICES DURING THE OPERATION

Confirm the dynamic balancing are needed according to spectrum and phase analysis. Direction of phase: reverse to the direction of rotation
www.sendig.com

phase
Reflecting slice

26

SELECTING PARAMETERS

Measure displacement or velocity for middle or low speed machines Measure velocity or acceleration for high speed machines

www.sendig.com

27

CONFIRM whether the trial is suitable

%52>ecnereffid eulav %52<ecnereffid eulav

lairt retfa dna erofeb

ssam lairt evom ssam evom ro esaercni 52<ecnereffid esahp ko ko 52>ecnereffid esahp

The radius of loading trial mass is as same as loading the amended mass
The turning speed is steady
www.sendig.com 28

1-PLANE BALANCING
Tacho sensor

Without influence coefficients

A
Accelerometer

www.sendig.com

907

29

Operation Basic

Prompt is displayed at the last line Press and key to move the cursor up and down Press Enter to select iterm

Press number keys to input digits


To other MENU, press PgDn or PgUp
30

www.sendig.com

Always make sure the Setting is correct before the balancing


Enter a digit, select 1 set of data from 10 Enter a digit, select plan number

Change by ENTER, use displacement or velocity for most machines Input sensitivity (from accelerometer certificate)

www.sendig.com

31

INITIAL MEASUREMENT

Press Enter to measure rotation speed first Press Enter for a moment to measure vibration after rotation speed become steady After phase and amplitude become steady, press Enter for a moment to end the measurement
www.sendig.com 32

TRIAL ESTIMATION

Input the 4 parameters When cursor on 6th line, press Enter to calculate trial range Stop the machine, fix a trial mass according to the range
33

www.sendig.com

TRIAL MEASUREMENT

Input phase and weight of the trial, confirm whether it will be removed afterward, restart the machine Move cursor to 6th line, press Enter to measure rotation speed When RPM steady, press Enter a moment to measure vibration When amplitude and phase steady, press Enter for a moment to end the measurement
www.sendig.com 34

TRIAL RESULT

See what the 6th line shows If YES displayed, press Pg Dn to go on If NO displayed, stop the machine, adjust trial mass, return to the early page of TRAIL MEASUREMENT, measure again
35

www.sendig.com

CALCULATION

Cursor on 2nd line, press ENTER to calculate influence coefficients The result is shown in 4th line
www.sendig.com

Cursor on 2nd line, press Enter to calculate balancing mass The result is shown in 3rd line
36

Decomposing/Splitting

Input the 2 angles Display the results If nothing displayed at right side, change the order of the 2 angles and re-enter

Pa2

Pa Pa1
www.sendig.com 37

VERIFICATION

Cursor on 2nd line, press Enter to measure rotation speed When RPM steady, press Enter a moment to measure vibration When amplitude and phase steady, press Enter for a moment to end the measurement The last 2 lines displays the results
www.sendig.com 38

1-PLANE BALANCING
With influence coefficients, you do not need to add trial mass. You need only measure the initial vibration
www.sendig.com 39

SETTING PARAMETERS
Set Yes for the question of Have influence Coefficient?

www.sendig.com

40

INITIAL MEASUREMENT

Press Enter to measure rotation speed Press Enter for a moment to measure vibration after rotation speed become steady When phase and amplitude become steady, press Enter for a moment to end the measurement
www.sendig.com 41

INPUT COEFFICIENTS

Move the cursor to the 4th line, input amplitude and angle of coefficient Press Pg Dn to the next page

www.sendig.com

42

Calculation, Decomposition & verification

calculate balancing mass

Decomposition and verification

are the same as


illustrated earlier

Pa2

Pa
www.sendig.com

Pa1

43

2-PLANES BALANCING
Without influence coefficients The main difference than 1-plane:
1.

Need to add trial mass one after another at the 1st plane and 2nd plane Need to use 2 vibration sensors
44

2.

www.sendig.com

Sensors & Cable connecting


Attach reflecting paper on shaft

www.sendig.com

45

SETTING PARAMETERS

www.sendig.com

46

INITIAL MEASUREMENT & TRIAL ESTIMATION

Get 2 lines of reading here

www.sendig.com

47

TRIAL I MEASUREMENT

Input phase and weight of the trial on plane 1, decide if it will be removed, restart the machine

www.sendig.com

48

TRIAL II MEASUREMENT

Input phase and weight of the trial on plane 2, decide if it will be removed, restart the machine

www.sendig.com

49

Calculation, Decomposition & Verification

calculate balancing mass

Decomposition
and verification are the same as illustrated earlier
www.sendig.com

Pa2 Pb2

Pa

Pb

Pb1 50

2-PLANES BALANCING
influence coefficients

With

With influence coefficients, you do not need to add trial mass. You need only measure the initial vibration.

www.sendig.com

51