Pilot Exciter
DC Exctr
Forcing Down
Forcing Up
Main Exciter
DC Exctr SYN Mach
CT PTS
Fixed Resistor
QL
QR
Exciter MOT Field Rheostat (Manual Control)
NL
NR
Automatic Control
Notes: (1) NL, NR - Close for small error QL, QR - Close for large error
AC Voltage Adjuster
DC Exctr
SYN Mach
CT
PTS
Rotating Amplifier
Automatic Control
PMG
MOT
DC Exctr
SYN Mach
CT
PTS
Regulator Transfer
Automatic Control
MOT PMG
AC Voltage Adjuster
PMG
Stator 41
Rotor
AC Exc
Shunt
GEN
CT
PT
AC
DC
Power Amp
AC Isolation
Voltage Adjuster
PM
PMG
N S
AC Exctr Arm.
SYN Mach
CT
PTS
Exciter Field
Gate Control
Automatic Control
AC Voltage Adjuster
Regulator Transfer
Rotating Elements Generator field diode wheel with fuses exciter armature PMG field
Permanent Magnet Generator (PMG)
Exciter
Feedback Inputs
Controlled Rectifier
Reference Inputs
Start-Up Power
SYN Mach
CT PTS
Power PT
DC Voltage Adjuster
Manual Control
Gate Control
Regulator Transfer
Automatic Control
AC Voltage Adjuster
41
GEN
PTs CT
Current Transducer 1pu =5v
Power AMP
4:1
Start RES
Voltage 1pu Transducer =5v
15 VDC Supply
OXP
+/-10v
AC Isolation Transducer
120 VAC
REG TRIP UNIT TRIP
DC Reg
DC Adj. BAL Meter
+/-10v
4 VAC
TO DC ADJ
+/-10v
Firing Ckt
+/-10v
SIG MIX
+/-10v
+/-10v
AC Adj.
WTA-300 STATIC
Maintain Output
Within +/- 2% of Pickup Point
Volts/Hertz Limiter
Adjustable Pickup Point 100%-120% Adjustable Time Delays 0 - 1000 seconds Inverse V/HZ Curve - ANSI C37.102
Overvoltage Limiter
Limits Generator Voltage Adjustable Pickup Points 100% - 130% Adjustable Time Delay 0 - 10 sec.
Protection
Overexcitation Protection Volts/Hertz Protection Overvoltage Protection Minimum Excitation Protection Loss of Field Protection Loss of Sensing
Overexcitation Protection
Configurable to Field Current or Field Voltage On Line - Off Line Adjustable Settings On Line - 100%-170% Full Load Value Off Line 100% to 130% No Load Value Dynamic Pickup based on Pressure/Temperature
Volts/Hertz Protection
Adjustable Pickup Point 100% -120% Adjustable Time Delay 0 - 1000 Seconds Inverse Volts/Hertz Curve Per ANSI C37.102 Alarm On Pickup - Trip after Time Delay
Overvoltage Protection
Adjustable Pickup 100-200% Generator voltage Adjustable Time Delay Alarm on Pickup Trip After Time Delay
Loss of Sensing
Detects complete/partial Loss of Voltage Intelligence Transfer based upon Adjustable Comparison Comparison Configurable to:
PT Secondary Voltage
Configurable To Transfer to
Backup Metering PTs (If existing) Manual Control
41
GEN
PTs CT
Current Transducer 1pu =5v
Power AMP
4:1
Start RES
Voltage 1pu Transducer =5v
15 VDC Supply
OXP
+/-10v
AC Isolation Transducer
120 VAC
REG TRIP UNIT TRIP
DC Reg
DC Adj.
4 VAC
TO DC ADJ
BAL Meter
Auto To All Modules
+/-10v
+/-10v
Firing Ckt
+/-10v
SIG MIX
+/-10v
+/-10v
AC Adj.
Damping
WTA-300 STATIC
DC Control In
Firing Circuit
Thyristor
Anode Cathode + I Gate -
I
+
+
VDRM
Anode-Cathode Voltage
IAV.
IAV.
One-Quadrant Converter
DC Output AC Input
VDC
+ +
IDC
Two-Quadrant Converter
VDC
+
DC Output AC Input
IDC
1 2 3
X1 X2
Y1 Y2
Z1 Z2 I
+ R L(>>R) -
1 2 3
X1 X2
Y1 Y2
Z1 Z2 I
+ R L(>>R) -
1 2 3
X1 X2
Y1 Y2
Z1 Z2 I
+ R L(>>R) -
1 2 3
X1 X2
Y1 Y2
Z1 Z2 I
+ R L(>>R) -
1 2 3
X1 X2
Y1 Y2
Z1 Z2 I
+ R L(>>R) -
(Transiently Only)
1.0
0.8
Firing Angle
Universal Relationship between the DC output terminal voltage and the firing angle, for all 2-quadrant phase-controlled converters (with smooth DC current).
DC Out
0o
0o
60o Firing Circuit DC In
Amp DC Out
Firing DC In
180o