Sunteți pe pagina 1din 76

Custody transfer references and applications of hydrocarbon measurement by Promass Coriolis mass flow meters

Promass F 6 and 10 hydrocarbons tests


After the flow meters are being manufactured and calibrated with water, the units are to SPSE in France for hydrocarbon calibrations according to OIML/API in order to ensure maximum performance on site.

15,000 liter prover at SPSE in France

with the four tanks in the back for the four different fluids

Promass F 6 and 10 hydrocarbons tests

Principle of operation

SPSE Fos sur Mer France

Promass F 6 and 10 hydrocarbons tests

The four hydro-carbons used for the calibration range of different densities and viscosities

SPSE Fos sur Mer France

Naphtha 690 kg/M3 Viscosity 0.7 cSt at ambient

Oural crude 853 kg/M3 Viscosity 7 cSt at ambient

Condensate 905 kg/M3 Viscosity 50 cSt at ambient

Fuel oil 960 kg/M3 Viscosity 180 cSt at ambient

Promass 10 bidirectional and tandem tests at SPSE Fos sur Mer France dec 2005
In the middle, the Coriolis flowmeter to be calibrated and verified bidirectional

Tandem unit SPSE Fos sur Mer France

Conclusions ( January - 2006)


NMI approvals now include bidirectional use of the Promass Coriolis meter for custody transfer !!!

bidirectional approval

SPSE Fos sur Mer France

Tandem (Dual) Promass 10 coriolis meter


2 Promass 10 meters running in parallel up to 3000 tons/hr. Running on Oural crude oil with 6-7 cSt and 853 kg/M3

SPSE Fos sur Mer France

Tandem (Dual) Promass 10 calibration


Calibration of both units, 48 FT10A and 48 FT10B, running in parallel

Running on Oural crude oil with 6-7 cSt and 853 kg/M3
Tandem calibration of unit A and B
SPSE Fos sur Mer France Maximum permissible error acc to OIML R117

Flow rate of tandem meters at 4.3 Bars (g): 3050 m3/hrs = 460,000 BPD

Preemraff Lysekil - Sweden


Berth 3
Turbine meter line has been removed Basket strainer will be removed shortly 2 each Promass F 10coriolis meters ready to be installed

Preemraff Lysekil - Sweden


Berth 2 Gasoil metering system Tag 48 FT 10 A / B
Consisting of 2 each Inlet / outlet spoolpieces 10/12 300 lb 2 each Promass 83 F
10 ANSI 300 lb modbus RTU frequency 10 pulses/ kg

Min flowrate for vessels non splashing volume 100 MT/H

Max flowrate 3000 MT/H


(3750 M3/H @ 800kg/M3)

Preemraff Lysekil - Sweden

Jetty 5
Tandem 6 coriolis meters with remote electronics for fuel oil

pipeline and meter run tracing and insolation

Preemraff Lysekil - Sweden


Jetty 5
loading/ unloading refined products gasoil

fueloil
Flowcontrol via anti cavitation butterfly valve Also used: avoiding cavitation controlling max rate via flow meter exciter current Bunker C flow meter

Preemraff System overview

Preemraff Lysekil - Sweden


Vessel Bro Gemini
Results of Surveyor Certificate of Quantity & Comparison to the 2 coriolis meters 48 FT 11 A 48 FT 11 B Medium: gasoil MK1
Load results on the Promasses 48 FT 11 A and B Batch gross volume (GOV) =8033.76 M3 Batch std. Volume Batch mass (GSV) = 7927.7 M3 (MTvac) = 6422.2

Deviation compared to ships figures incl. VEF (7921.793 7927.7) / 7927.7*100%=

0.075 %
Deviation compared to ships figures excl. VEF

Value of VEF unknown

Preemraff Lysekil - Sweden


Study:
crude oil harbour intention to install 2 metering skids consisting of 12 ea 10coriolis meters In order to cope with a total flowrate of 18000 M3/H Or 5000 liters/sec

FPSO SSP Piranema 2 x 10 PromassF

VIP Seminar "Oil & Gas" - 19 March 2004

FPSO Ciadade de Vitoria

Onsite training for crew on 6 Coriolis mass flow meter

VIP Seminar "Oil & Gas" - 19 March 2004

FPSO Ciadade de Vitoria

VIP Seminar "Oil & Gas" - 19 March 2004

Replacement for Ultra sonic within 1 week

FPSO ExxonMobil Angola, 250 km Offshore (West) Luanda 1,500 m water depth 250,000 BOPD (largest in world) 28 30API
E+H at its full capacity Requested on Friday in Houston Produced and delivered within 3 days Thursday: On-hand training (while waiting for spool peace) Friday: Installed and commissioned

VIP Seminar "Oil & Gas" - 19 March 2004

Offshore Crude Oil Test Separator


Instrument: Industry: Fluid: Promass 83F Oil & Gas Crude Oil

Reason:
Previous meter frequently clogged Flow measurement after test separator Replacement of U-tube flowmeter Self-draining

Benefits:
No maintenance Reliable measurement

Shell Brunei, Offshore Platform AMPP-12


With courtesy of Shell

(No clogging!)

Footprint not only offshore expensive


Conventional and simple design to do the same

VIP Seminar "Oil & Gas" - 19 March 2004

Oil metering in retrofit


Conventional metering skid designs require large space and are a heavy load for the installation

The same metering quality can be obtained by use of a compact Coriolis Promass F on much smaller footprint

Custody transfer applications from China

China, Shanghai Terminal


Challenge: Reduce discrepancies between ship and tank measurement

Environment: Tropical environment at cost line of Shanghai


Solution: 2 x 10Promass in ship offloading lines

Product group: Industry: Installed at:

Promass 83F 10@ O&G June 2006

Benefit: - Accurate metering - Detection of air or gas in oil - none-stop operation no proving required - Oil quality control via density measurement

Company profile

Company profile

Second metering unit with 10 Promass at front of ship

Ship Loading

Ship Loading

Proline Promass 83F1H Application: Loading Ship 4 sets Diesel, Gasoline DC 2.0

Titan Proposal

Proline Promass 84F80 Application: Loading Truck 14 Sets Chemical Products DC > 2.0

Yulin Refinery
Proline Promass 80F80

Application: Loading Truck 8 Sets Diesel, Gasolene DC 2.0

Changyi Refinery
Proline Promass 83F80 Application: Loading Truck 8 Sets Diesel, Gasolene DC 2.0

Yanshan Refinery
With Pressure Compensation Measuring range 0.5 bar~ 16 bar

Proline Promass 83F Endress+Hauser 83F1F-AD2SAACEBBA5

2 pics

Ship loading in China

83F2F-AAASAACABGAN 2 Customer: Dalian Beiliang company P.R.China

Application custody transfer of gasoline, diesel oil, kerosene

The first 10 Promass in China 2005

One 83F2F for testing on Yangzi Metrology calibration rig Two 83F2F for ship loading--- Dalian Beiliang Jetty custody transfer of gasoline, diesel oil, kerosen, tested at NIM China One 83F2F for Luoyang refinery plant for mass balance of crude inflow

Testing on Yangzi Metrology station


Yangzi Metrology station is authorized by CNAL, special flow calibration centre for SINOPEC.

Calibration Rigs :Vol. / Grav Flow range0.5~900m3/h

System uncertainty+/- 0.05%

Testing on Yangzi Metrology station


Promass 83F2F-AD1SAACABGAN being installed

After testing, Promass 83F2F-AD1SAACABGAN being for road show

Chinese human interface

Chinese interface is deeply greeted

Exceeding accuracy requirements

accuracy+/0.072%

0.1

Testing at NIM China


NIM China-- National Institute Metrology is the highest metrology institute in China

Testing at NIM China

Calibration Rigs: Vol. / Gravimetric Flow range0.5~960m3/h System uncertainty +/- 0.05%

Easy installation at NIM

Chinese interface is deeply greeted Small size is easy for installation

NIM official test report

Certificate of verification

83F2F-AAASAACABGAN Series No: 75010502000

Verification conclusion: 0.1

Application: Custody transfer ship loading in Dalian Jetty

Luoyang refinery plant


Customer: SINOPEC Luoyang Refinery plant Application: Refinery tower four outlets flow monitoring One 83F1H---gasoline Two 83F1F---Diesel oil One 83F2F---Crude oil

SASOL, South Africa

Jan 2005 First 10 Promass order for China 5 nos

Customer: Sasol ordered in China Application custody transfer ship on and offoading gasoline, diesel oil, kerosene

CT metering station on barge in China

Tandem set of 6 Promass on floating jetty. 2 x 150kg. Standard mass flow meter were 2 x 750kg, too heavy

LPG terminal in Korea

Liquid propane terminal Korea Process:


Propane liquid unloading process from ship to tank yard.

Solution:
Earlier SK gas measured liquid Propane with turbine flowmeter. SK gas required reliable and precise flow measurement to confirm ship unloading.

Process Specs:
Fluid: Pressure: Temperature: Flow Range: Propane liquid 3 ~ 5 bar -42C 900 ~ 1,200 ton/ hrs

Instrument: Model: 83F2F-CABSAACAAAAA Size/Lining: 250 A Software/Bus: HART

Company profile
Company: Location: SK Gas Terminal Pyeong taek in KOREA

Key Success Factors:

Compact volume of mass flowmeter against Rheonics and simple installation environment against Ovals turbine flowmeter and Rheonicss mass flowmeter and

Date: 12-05-2005 Reference: DRF

Installation directly at point of transfer

Position of Promass

Small foot print requirement on jetty

No meter run, no flow conditioner, no filter, no prover

Terminal and loading arms

Position of Promass

Detailed application information

No vibration or pipe stress compensator installed. With fluid temperature of 42C and ambinet temperature of up to over 30C pipe will be under stress.

Weights and Measure approved calibration trailer


Johan van Jaarsveldt, South Africa

VIP Seminar "Oil & Gas" - 19 March 2004

Mobile flow metering and validation


Fully equipped unit with transmission cable, drip pans and purge installation.

Nitrogen purge port

Approved by SABS dep. of Metrology, South Africa

VIP Seminar "Oil & Gas" - 19 March 2004

10 Mobile flow metering and validation

Approved by SABS dep. of Metrology, South Africa

VIP Seminar "Oil & Gas" - 19 March 2004

6 Mobile flow metering and validation

Approved by SABS dep. of Metrology, South Africa

VIP Seminar "Oil & Gas" - 19 March 2004

3 and 4 Mobile flow metering and validation

Approved by SABS dep. of Metrology, South Africa

VIP Seminar "Oil & Gas" - 19 March 2004

Mobile flow metering and validation

Approved by SABS dep. of Metrology, South Africa

Overall repeatability exceeding 0.02%


Meter size 3 and 4 6 10 Skid weight 750 kg 850 kg 1,140 kg Skid flow range 0 - 1,500/2,500 kg/min = 22,500 BPD 0 - 5,000 kg/min 0 - 10,000 kg/min = 45,000 BPD = 90,000 BPD

Detailed drawings are available

Total Netherlands
Nills Mureau, SCNL

DOW Terneuzen, BENELUX

Fingerprint has been stored and Dow intends to do periodic evaluations in corporation with us to gather some more diagnostic experiences. Details and pictures you'll find attached.

TOTAL Refinery

Naphta transport from refinery to customer in 6 pipeline Promass 84F 4600lbs RF ANSI connected to OMNI model 6000 Flow = 200-300 m3/hr ; P = 41-50 barg ; T = 38-75C Viscosity = 1 cSt @ 38C ; Density = 650-700 kg/m3

TOTAL Refinery

LPG (Propane/Butane) jetty shiploading from 10 pipeline Promass 84F 4300lbs RF ANSI connected to OMNI model 6000

Flow = 350 m3/hr ; P = 8-14 barg ; T = -40 ..+38C


Viscosity = <0,7 cSt ; Density = 550 kg/m3

DOW Benelux, refinery


Naphta Installed 2002 Paul Borggreve, SCNL

Pigable loading arm metering


United Kingdom

Promass 64 - Mobil Oil

Contrec 1010 OIML approved tanker loading terminal

Promass 64 - Mobil Oil

Promass 64M

Promass 64 - Mobil Oil

Flexible Loading Arm with Automatic Pig System

Promass 64 - Mobil Oil

Two Stage Flow Control Valves

Promass 64 - Mobil Oil

Loading a Tanker - Wax Emulsion

Shell lub oil loading station


United Kingdom

Modern UK loading bay using Promass

Tanker loading using Profibus DP network

Previous metering technology

UK W&M approved Promass 64

Shell crude oil CT metering statio


Brunei, Malaysia

Very compact design for most accurate measurement


Production skid in Venezuela: Accurate measurement even under pulsating flow condition. Calibrated against prover according to Venezuela W&M