Documente Academic
Documente Profesional
Documente Cultură
www.huawei.com
Foreword
The mobility of UE The mobile system is composed by cells which the coverage ability is limited.
Providing the continuous service in mobile system is the basic element in QoS.
Page1
Objectives
Page2
Contents
1. Introduction of Handover 2. Measurement of Handover 3. The Basic Handovers
Page3
Contents
1. Introduction of Handover 2. Measurement of Handover 3. The Basic Handovers
Page4
Providing the continuous service in mobile system is the basic element in QoS
The load balance: sharing the resource The hierarchy divided by speed and service: high efficiency of using resource
Page5
Active Set Monitored Set Detected set Radio Link (RL) Radio Link Set (RLS)
maximum ratio combination selection combination The soft handover gain CPICH
Page6
Page7
Item
The number of RLs in active set after handover Interruption during handover The frequencies of cells
Soft Handover
Several One
Hard Handover
No
Yes
Page8
Item
UL combination
Soft Handover
Signal combined in RNC by selective combination
Softer Handover
Signal combined in NodeB by maximum ratio combination
DL combination
Page9
Soft Handover
RNC
NodeB 1
NodeB 2
Cell A
Cell B
Page10
Softer Handover
RNC
NodeB
Cell A Cell B
Page11
Hard Handover
RNC
NodeB 1
NodeB 2
Cell A
Cell B
Page12
Measurement phase
Measurement
Decision
Execution
Yes
Execution phase
Page13
Contents
1. Introduction of Handover 2. Measurement of Handover 3. The Basic Handovers
Page14
Contents
2. Measurement of Handover
2.1 Measurement Control and Measurement Report 2.2 Measurement Phase
Page15
Measurement Control
UE
UTRAN
MEASUREMENT CONTROL
Page16
Measurement Report
UE
UTRAN
MEASUREMENT REPORT
Page17
Contents
2. Measurement of Handover
2.1 Measurement Control and Measurement Report 2.2 Measurement Phase
Page18
Measurement Model
parameters parameters
Layer 1 filtering
Layer 3 filtering
C C'
A is measurement value at the physical layer B is the measurement value after layer 1 filtering at physical layer. The value goes from the physical layer to high layer C is measurement after processing in the layer3 filter C is another measurement value D is measurement report information sent on the radio interface or Iub interface
Page19
Measurement Quantity
Ec/No
RSCP
RSSI
Page20
IntraFreqMeasQuantity
Parameter name: Intra-frequency measure quantity The default value of this parameter is Ec/No
InterFreqMeasQuantity
Parameter name: Inter-frequency measure quantity The default value of this parameter is Both
MeasQuantityOf3A
Parameter name: 3A Measure Quantity The default value of this parameter is RSCP
Page21
Layer 3 filtering
Fn ! (1 a) Fn 1 a M n
Where:
Fn is the new measurement value after filtering. Fn-1 is the last measurement value after filtering. Mn is the latest measurement value from the physical layer. a = 1/2(k/2) (k is set to Intra-freq meas L3 filter coeff)
Page22
FilterCoef
Parameter name: Intra-frequency measurement filter coefficient The default value of this parameter is D3
InterFreqFilterCoef
Parameter name: Inter-frequency measure filter coefficient The default value of this parameter is D3
InterRATFilterCoef
Parameter name: Inter-RAT filter coefficient The default value of this parameter is D3
Page23
Page24
Contents
1. Introduction of Handover 2. Measurement of Handover 3. The Basic Handovers
Page25
Contents
3. The Basic Handovers
3.1 Soft Handover 3.2 Intra-frequency Hard Handover 3.3 Inter-frequency Hard Handover 3.4 Inter-RAT Hard Handover 3.5 Blind Handover
Page26
Contents
3. The Basic Handovers
3.1 Soft Handover 3.2 Intra-frequency Hard Handover 3.3 Inter-frequency Hard Handover 3.4 Inter-RAT Hard Handover 3.5 Blind Handover
Page27
During handover, UE has several RLs with different cells The handover among different cells which are in same RLS can be softer handover
Page28
Advantages
Disadvantages
Page29
Measurement quantity
Reporting mode
Periodic reporting Event trigger reporting Event trigger reporting to Periodic reporting
Event type
1A,1B,1C,1D
Page30
Page31
Page32
Example of 1A Event
A: signal curve of the best cell in the active set B: signal curve of a cell in the monitoring set C: The 1A curve
Page33
INTRARELTHDFOR1ACS
Parameter name: CS service 1A event relative threshold The default value of this parameter is 6 ( 3dB )
INTRARELTHDFOR1APS
Parameter name: PS service 1A event relative threshold The default value of this parameter is 6 ( 3dB )
Page34
HYSTFOR1A
Parameter name: 1A event hysteresis The default value of this parameter is 0( 0dB )
TRIGTIME1A
Parameter name: 1A event trigger delay time The default value of this parameter is D320 ( 320ms )
Page35
Page36
Example of 1B Event
A: signal curve of the best cell in the active set B: signal curve of a cell in the monitoring set C: The 1B curve
Page37
INTRARELTHDFOR1BCS
Parameter name: CS service 1B event relative threshold The default value of this parameter is 12 ( 6dB )
INTRARELTHDFOR1BPS
Parameter name: PS service 1B event relative threshold The default value of this parameter is 12 ( 6dB )
Page38
HYSTFOR1B
Parameter name: 1B event hysteresis The default value of this parameter is 0( 0dB )
TRIGTIME1B
Parameter name: 1B event trigger delay time The default value of this parameter is D640 ( 640ms )
Page39
Page40
Example of 1C Event
A: signal curve of the best cell in the active set B: signal curve of a cell in the active set C: signal curve of the worst cell in the active set D: signal curve of a cell in the monitoring set E: The 1C curve Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
HYSTFOR1C
Parameter name: 1C event hysteresis The default value of this parameter is 8( 4dB )
TRIGTIME1C
Parameter name: 1C event trigger delay time The default value of this parameter is D640 ( 640ms )
Page42
Page43
Example of 1D Event
A: signal curve of the best cell in the active set B: signal curve of a cell in the active set or monitoring set C: Th1D curve
Page44
HYSTFOR1D
Parameter name: 1D event hysteresis The default value of this parameter is 8( 4dB )
TRIGTIME1D
Parameter name: 1D event trigger delay time The default value of this parameter is D640 ( 640ms )
Page45
Weight
Parameter name: Weighted factor The default value of this parameter is 0
SHOQualmin
Parameter name: Min quality THD for SHO The default value of this parameter is -24(-24 dB)
CELLINDIVIDALOFFSET
Parameter name: Cell offset The default value of this parameter is 0 ( 0dB )
Page46
Contents
3. The Basic Handovers
3.1 Soft Handover 3.2 Intra-frequency Hard Handover 3.3 Inter-frequency Hard Handover 3.4 Inter-RAT Hard Handover 3.5 Blind Handover
Page47
During handover, UE has only one RL with one cell Switch off the RL with the original cell, then setup the RL with target cell
Page48
Advantages
Disadvantages
Page49
BEBITRATETHD
Parameter name: BE service handover rate threshold The default value of this parameter is 384k
Page50
Contents
3. The Basic Handovers
3.1 Soft Handover 3.2 Intra-frequency Hard Handover 3.3 Inter-frequency Hard Handover 3.4 Inter-RAT Hard Handover 3.5 Blind Handover
Page51
The frequency of original cell and source cell are different There is only one RL for the UE The compressed mode is needed
Page52
Compressed Mode
Purpose
Categories
Realization Methods
Page53
Measurement quantity
Reporting mode
Periodic reporting Event trigger reporting Event trigger reporting to Periodic reporting
Event type
2B,2C,2D,2F
Page54
QUsed e TUsed 2 d H 2 d / 2
Page56
InterFreqCSThd2DEcN0
Parameter name: Inter-freq CS measure start Ec/No THD The default value of this parameter is -14 dB
InterFreqPSThd2DEcN0
Parameter name: Inter-freq PS measure start Ec/No THD The default value of this parameter is -14 dB
Page57
InterFreqCSThd2DRSCP
Parameter name: Inter-freq CS measure start RSCP THD The default value of this parameter is -95 dBm
InterFreqPSThd2DRSCP
Parameter name: Inter-freq PS measure start RSCP THD The default value of this parameter is -95 dBm
Page58
HYSTFOR2D
Parameter name: 2D event hysteresis The default value of this parameter is 4( 2dB )
TRIGTIME2D
Parameter name: 2D event trigger delay time The default value of this parameter is D320 ( 320ms )
Page59
QUsed u TUsed 2 f H 2 f / 2
Page60
InterFreqCSThd2FEcN0
Parameter name: Inter-freq CS measure stop Ec/No THD The default value of this parameter is -12 dB
InterFreqPSThd2FEcN0
Parameter name: Inter-freq PS measure stop Ec/No THD The default value of this parameter is -12 dB
Page61
InterFreqCSThd2FRSCP
Parameter name: Inter-freq CS measure stop RSCP THD The default value of this parameter is -92 dBm
InterFreqPSThd2FRSCP
Parameter name: Inter-freq PS measure stop RSCP THD The default value of this parameter is -92 dBm
Page62
HYSTFOR2F
Parameter name: 2F event hysteresis The default value of this parameter is 4( 2dB )
TRIGTIME2F
Parameter name: 2F event trigger delay time The default value of this parameter is D1280 ( 1280ms )
Page63
, and
QUsed e TUsed 2b H 2b / 2
Page64
InterFreqCovHOCSThdEcN0
Parameter name: Inter-freq CS target frequency trigger Ec/No THD The default value of this parameter is -12 dB
InterFreqCovHOPSThdEcN0
Parameter name: Inter-freq PS target frequency trigger Ec/No THD The default value of this parameter is -12 dB
Page65
InterFreqCovHOCSThdRSCP
Parameter name: Inter-freq CS target frequency trigger RSCP THD The default value of this parameter is -92 dBm
InterFreqCovHOPSThdRSCP
Parameter name: Inter-freq PS target frequency trigger RSCP THD The default value of this parameter is -92 dBm
Page66
IFHOUsedFreqCSThdEcN0
Parameter name: Inter-freq CS Used frequency trigger Ec/No THD The default value of this parameter is -12dB
IFHOUsedFreqPSThdEcN0
Parameter name: Inter-freq PS Used frequency trigger Ec/No THD The default value of this parameter is -12 dB
Page67
IFHOUsedFreqCSThdRSCP
Parameter name: Inter-freq CS Used frequency trigger RSCP THD The default value of this parameter is -92dBm
IFHOUsedFreqPSThdRSCP
Parameter name: Inter-freq PS Used frequency trigger RSCP THD The default value of this parameter is -92 dBm
Page68
HYSTFOR2B
Parameter name: 2B event hysteresis The default value of this parameter is 4( 2dB )
TRIGTIME2B
Parameter name: 2B event trigger delay time The default value of this parameter is D0 ( 0ms )
Page69
Page70
InterFreqNCovHOThdEcN0
Parameter name: Inter-freq CS target frequency trigger Ec/No THD The default value of this parameter is -16 dB
Hystfor2C
Parameter name: 2C hysteresis The default value of this parameter is 6 (3dB)
TrigTime2C
Parameter name: 2C event trigger delay time The default value of this parameter is D640 (640ms)
Page71
Contents
3. The Basic Handovers
3.1 Soft Handover 3.2 Intra-frequency Hard Handover 3.3 Inter-frequency Hard Handover 3.4 Inter-RAT Hard Handover 3.5 Blind Handover
Page72
UMTS->GSM handover
UMTS->GSM coverage-based handover UMTS->GSM load-based handover UMTS->GSM service-based handover
GSM->UMTS handover
Page73
Advantages
For coverage, it can solve the problems from one system to another system For capacity, it can enhance the utilizing efficiency of old equipments(2G->3G)
Disadvantages
The flow is complicated, and it demands higher compatibility for equipments Demands more complicated UE
Page74
Measurement quantity
CPICH_Ec/N0 CPICH_RSCP BOTH
Reporting mode
PERIODICAL_REPORTING EVENT_TRIGGER
Event type
2D, 2F 3A, 3C
Page75
Page76
Q Used e TUsed2d - H 2d / 2
Page77
INTERRATCSTHD2DECNO
Parameter name: Inter-RAT CS measure start Ec/No THD The default value of this parameter is -14 ( -14 dB )
INTERRATPSTHD2DECNO
Parameter name: Inter-RAT PS measure start Ec/No THD The default value of this parameter is -15 ( -15 dB )
Page78
INTERRATCSTHD2DRSCP
Parameter name: Inter-RAT CS measure start RSCP THD The default value of this parameter is -100 ( -100 dBm )
INTERRATPSTHD2DRSCP
Parameter name: Inter-RAT PS measure start RSCP THD The default value of this parameter is -110 (-110 dBm )
Page79
HYSTFOR2D
Parameter name: 2D hysteresis The default value of this parameter is 4 ( 2 dB )
TRIGTIME2D
Parameter name: 2D event trigger delay time The default value of this parameter is D320 (320 ms )
Page80
Q Used u TUsed2f H 2f / 2
Page81
INTERRATCSTHD2FECNO
Parameter name: Inter-RAT CS measure stop Ec/No THD The default value of this parameter is -12 ( -12 dB )
INTERRATPSTHD2FECNO
Parameter name: Inter-RAT PS measure stop Ec/No THD The default value of this parameter is -13 ( -13 dB )
Page82
INTERRATCSTHD2FRSCP
Parameter name: Inter-RAT CS measure stop RSCP THD The default value of this parameter is -97 ( -97 dBm )
INTERRATPSTHD2FRSCP
Parameter name: Inter-RAT PS measure stop RSCP THD The default value of this parameter is -107 (-107 dBm )
Page83
HYSTFOR2F
Parameter name: 2F hysteresis The default value of this parameter is 4 ( 2 dB )
TRIGTIME2F
Parameter name: 2F event trigger delay time The default value of this parameter is D1280 (1280 ms )
Page84
Q Used e TUsed3a H 3a / 2
M OtherRat CIOOtherRat u TOtherRat H 3a / 2
Page85
IRHOUSEDFREQCSTHDECNO
Parameter name: Inter-RAT CS Used frequency trigger Ec/No THD The default value of this parameter is -12 ( -12 dB )
IRHOUSEDFREQPSTHDECNO
Parameter name: Inter-RAT PS Used frequency trigger Ec/No THD The default value of this parameter is -13 ( -13 dB )
Page86
IRHOUSEDFREQCSTHDRSCP
Parameter name: Inter-RAT CS Used frequency trigger RSCP THD The default value of this parameter is -97 ( -97 dBm )
IRHOUSEDFREQPSTHDRSCP
Parameter name: Inter-RAT PS Used frequency trigger RSCP THD The default value of this parameter is -107 (-107 dBm )
Page87
INTERRATCOVHOCSTHD
Parameter name: Inter-RAT CS handover decision THD The default value of this parameter is 16 ( -95 dBm )
INTERRATCOVHOPSTHD
Parameter name: Inter-RAT PS handover decision THD The default value of this parameter is 16 ( -95 dBm )
Page88
HYSTFOR3A
Parameter name: 3A hysteresis The default value of this parameter is 4 ( 2 dB )
TRIGTIME3A
Parameter name: 3A event trigger delay time The default value of this parameter is D0 ( 0 ms )
Page89
CELLINDIVIDALOFFSET
Parameter name: Cell individual offset The default value of this parameter is 0 ( 0 dB )
Page90
Page91
INTERRATNCOVHOCSTHD
Parameter name: Inter-RAT CS handover decision THD The default value of this parameter is 21 ( -90 dBm )
INTERRATNCOVHOPSTHD
Parameter name: Inter-RAT PS handover decision THD The default value of this parameter is 21 (-90 dBm )
Page92
HYSTFOR3C
Parameter name: 3C hysteresis The default value of this parameter is 0 ( 0 dB )
TRIGTIME3C
Parameter name: 3C event trigger delay time The default value of this parameter is D640 ( 650 ms )
Page93
PENALTYTIMEFORINTERRATHO
Parameter name: Inter-RAT handover failure penalty timer length The default value of this parameter is 30 ( 30 s )
INTERRATHOATTEMPTS
Parameter name: Inter-RAT handover max attempt times The default value of this parameter is 16
Page94
INTERRATMEASTIME
Parameter name: Inter-RAT measure timer length [s] The default value of this parameter is 60 ( 60 s )
Page95
Contents
3. The Basic Handovers
3.1 Soft Handover 3.2 Intra-frequency Hard Handover 3.3 Inter-frequency Hard Handover 3.4 Inter-RAT Hard Handover 3.5 Blind Handover
Page96
Blind handover means UE can directly handover to the neighboring cell without measuring it.
Page97
10 LogM Old e T1 f H 1 f / 2
Where:
MOld is the measurement value of the cell signal that becomes worse T1f is the absolute threshold of event 1F. H1f is the hysteresis value of event 1F.
Page98
Cell 1
1F Trigger Delay Time Absolute Threshold T1f Hysteresis H1f /2
Time
Reporting event 1F
Page99
INTRAABLTHDFOR1FECNO
Parameter name: 1F event absolute EcNo threshold The recommended value is -24 dB
INTRAABLTHDFOR1FRSCP
Parameter name: 1F event absolute RSCP threshold The recommended value is -115 dBm
Page100
HYSTFOR1F
Parameter name: 1F hysteresis The recommended value is 8, namely 4 dB
TRIGTIME1F
Parameter name: 1F event trigger delay time The recommended value is D640, namely 640 ms
Page101
After receiving event 1F of best cell from UE, the RNC would check if blind handover neighbor is configured for the cell.
If multiple blind handover neighbors are configured, the RNC would perform blind handover to the target cell with the highest priority
Page102
BLINDHOFLAG
Parameter name: Blind handover flag The default value is FALSE
BLINDHOPRIO
Parameter name: Blind handover Priority The value is set according to actual situation.
Page103
Thank you
www.huawei.com