Sunteți pe pagina 1din 20

ABB Group - 1 DCS800 presentation

DCS800 built on DCS technology

DCS

DCS800 - ABB DC drives portfolio


Engineering Skills Complexity

Metals Cement, Mining Small machinery food, wire drawing, mixer, extruders Cranes Test rigs, ski lifts System integrators P&P

ABB Group - 2 DCS800 presentation

Sales agents Distributors


Power

DCS800 - ABB DC drives - Status Quo


DCS 600 Engineering Skills Complexity

DCS800
DCS 500
1995

1997

DCS 400

ABB Group - 3 DCS800 presentation

1999
Power

DCS800 - The next generation


The best of four worlds

DCS800

ABB Group - 4 DCS800 presentation

DCS800 - Scalability
Serial Fast monitoring of different drives scaled to a wide variety of applications The basic package can be communication

Basic package

IEC 61131 Programming

Master-follower, drive-to-drive, 12 pulse & hard parallel

Isolated I/O
ABB Group - 5 DCS800 presentation

Extension I/O External Field exciter

Interface to the ABB fiber optic world: SDCS-COM-8

DC drives - Power

DCS800
230 VAC - 990 VAC D7 up to 1200 VAC and up to 1500 VDC 20 A - 5200 A 10,000 A hard parallel 20,000 A 12-pulse parallel

DCS 500B

DCS 400

230 VAC - 990 VAC A7 up to 1190 VAC

230 VAC - 500 VAC


20 A - 5200 A 10,000 A hard parallel 20,000 A 12-pulse parallel 40C ambient 50 Hz / 60 Hz

20 A - 1000 A -

40C ambient 50 Hz / 60 Hz

40C ambient 50 Hz / 60 Hz

ABB Group - 6 DCS800 presentation

DC drives - Excitation

DCS800
OnBoard / internal max. 25 A (1 / 3 - ph) external 35 A (1 / 3 - ph), 50 A / 60 A (1 - ph), 20 A - 520 A (3 - ph) thyristor technology

DCS 500B
internal max. 16 A (1 - ph) external -, 50 A / 60 A (1 - ph), 20 A - 520 A (3 - ph) thyristor technology

DCS 400
internal max. 20 A (1 - ph) -

IGBT technology

ABB Group - 7 DCS800 presentation

DC drives - Family

DCS800
modules single cabinets line ups revamp solutions

DCS 500B
modules single cabinets line ups revamp solutions

DCS 400
modules -

ABB Group - 8 DCS800 presentation

DC drives - Large drives options

DCS800

DCS 500B

DCS 400

12-pulse serial 12-pulse sequential 12-pulse parallel all digital

12-pulse parallel analog

master - follower digital

master - follower analog

master - follower analog

ABB Group - 9 DCS800 presentation

DC drives - Communication

DCS800
serial communication, fieldbus

DCS 500B
serial communication, fieldbus

DCS 400
serial communication, fieldbus

communication via DDCS (fiber optics)


drive-to-drive communication via DCSLink

ABB Group - 10 DCS800 presentation

DC drives - Control performance

DCS800

DCS 500B
AI cycle time 5 ms speed controller cycle time 5 ms not synchronized with current controller min. scan time overriding control 5 ms

DCS 400
AI cycle time 5 ms speed controller cycle time 5 ms not synchronized with current controller min. scan time overriding control 5 ms

fast speed reference via AI AI cycle time 3.3 ms / 2.77 ms synchronized with mains frequency speed controller cycle time 3.3 ms / 2.77 ms synchronized with mains frequency and current controller min. scan time overriding control 2 ms

ABB Group - 11 DCS800 presentation

DC drives - Drive adaptation

DCS800
parameters macros

DCS 500B
parameters macros

DCS 400
parameters macros -

Adaptive Program (AP) function blocks all IEC 61131 program languages (e.g. function blocks)

ABB Group - 12 DCS800 presentation

DC drives - Interfaces

DCS800
ACS800 interface options (DDCS, DW, AIMA) AC options (Panel, RAIO, RDIO, AIMA, DWL, DW) isolated I/O (SDCSIOB-2x, SDCS-IOB-3)

DCS 500B
limited interface options

DCS 400
no options

isolated I/O (SDCSIOB-2x, SDCS-IOB-3, SDCS-IOE-1)

ABB Group - 13 DCS800 presentation

DC drives - Hardware

DCS800
2 printed circuit boards (D1 - D4)

DCS 500B
4 printed circuit boards (C1, C2, C2b)

DCS 400
3 printed circuit boards

standard I/Os:
5 AI, 3 AO, 8 DI, 8 DO

standard I/Os:
5 AI, 3 AO, 8 DI, 8 DO

standard I/Os:
2 AI, 2 AO, 8 DI, 5 DO

extended I/Os:
4 AI, 4 AO, 6 DI, 4 DO

extended I/Os:
2 AI, 0 AO, 7 DI, 0 DO

ABB Group - 14 DCS800 presentation

DC drives - Commissioning tools

DCS800
DWL wizard DWL AP

DCS 500B

DCS 400
wizard

DriveWindow DriveWindow Light

DDCTool -

DriveWindow Light

DCS800 panel (same hardware as ACS550) is multilingual

CDP312 panel is multilingual

DCS400 PAN is multilingual

autotuning for all controllers, speed feedback and field weakening

autotuning for armature and field current

autotuning for all controllers and field weakening

ABB Group - 15 DCS800 presentation

DC drives - Programming tools

DCS800
AC 800M (freely programmable) via DDCS CoDeSys (IEC 61131 programming tool) Adaptive Program (16 blocks)

DCS 500B
-

DCS 400
-

GAD (engineering tool) 250 blocks

ABB Group - 16 DCS800 presentation

DC drives - Applications

DCS800
stand alone and system drives

DCS 500B
stand alone and small system drives

DCS 400
stand alone

metals P&P printing mine hoists cranes very large drives and all applications of DCS 500B and DCS 400 etc ...

winders ski lifts cement excitation cranes cutters non motoric applications etc ...

presses

conveyors cable draws extruders cutters etc ...

ABB Group - 17 DCS800 presentation

DC drives - Sales strategy

DCS800
OEMs system integrators end users ABB internal

DCS 500B
OEMs system integrators end users -

DCS 400
OEMs system integrators end users -

distributors

distributors

distributors

ABB Group - 18 DCS800 presentation

DC drives - Prices

DCS800
unbeatable (excitation included)

DCS 500B
competitive

DCS 400
very competitive

ABB Group - 19 DCS800 presentation

ABB Group - 20 DCS800 presentation

Thank You for Your attention!

S-ar putea să vă placă și