Sunteți pe pagina 1din 28

Raisecom RC951E-4FEE1

Ethernet over PDH Remote Gateway

Content
Introduction Applications Technical Data

Configure EoP

RC951E-4FEE1 INTRODUCTION

Introduction RC951E-4FEE1
Raisecom RC951E-4FEE1 is Raisecom's intelligent Ethernet Demarcation Device (EDD) with E1 uplink. RC951E-4FEE1 offers 4 FE downlink ports and 1 E1 uplink. The device can be either deployed in a point to point topology, or in a point to multi-point topology as CPEs. Raisecom EDD is not only capable of doing what a layer-2 switch is capable of on Ethernet switching, but is inherently good at network diagnostices as a device working on the border. Apart from local CLI management, RC951E-4FEE1 is also available with inband web-based management.

RC951E-4FEE1

Applications

Point to point Point to multipoint

Point-to-point application with E1 uplink

Point-to-multipoint application with E1 uplink

RC951E-4FEE1

Technical Data

RC951E-4FEE1 Technical Data (1/2)


Single VCG, HDLC/GFP encapsulation software configurable Support LCAS, VCG members automatically adjust when E1 link status changes VCG-level fault pass through E1 loopback detection and Ethernet loop detection Ethernet cable diagnostics Ingress rate limit and egress traffic shaping

RC951E-4FEE1 Technical Data (2/3)


Storm control of broadcast, multicast, unicast and dlf frames 8K MAC address table, full MAC address table management IEEE802.1Q and IEEE802.1ad, VLAN tagging and stacking 4 queue QoS, CoS/DSCP/port-based, queue scheduling rule including sp, wrr, sp+wrr IEEE802.3ad link aggregation Layer 2/layer 3 SLA

RC951E-4FEE1 Technical Data (3/2)


IEEE802.3ah OAM IEEE802.1ag CFM, and ITU-T recommendation Y.1731 CLI management access by local CONSOLE, Telnet or SSH In-band web-based management GUI-based concentratively management on Raisecom NView NNM system

RC951E-4FEE1

Configure EoP

Configure EoP
Carrier Ethernet Backbone

VLAN 110
RAISECOM RC953-FE8E1

VLAN 110 SDH


RAISECOM RC953-FE8E1

E1

E1

RC953-4FEE1 IP: 192.168.1.10


IP192.168.1.12 VLAN100

E1

E1

RC953-4FEE1
IP192.168.1.11 VLAN100

GFP encapsulation mode Client 1-4 correspond to FE port 1,2,3,4 Line 1 corresponds to inner switch port aggregate traffics from FE port 1, 2, 3, 4. It work under trunk mode . Data traffics using VLAN 110. Make sure the E1 are contained in the VCG Remotely manage RC953-4FE8E1 by telnet from central management sever PC Configure IP address 192.168.1.12/24 and 192.168.1.11/24 and VLAN ID 100. Line 1 trunk allows VLAN 100 to pass as well as other VLANs of traffics.

Configure EoP
Login to RC953-4FEE1
Via Serial

Configure EoP (serial)


Login to RC953-4FEE1

Login : raisecom Password : Raisecom

Priviliege Mode

Password : raisecom

Configure EoP (serial)


Create Vlan

GFP Mode

Configure EoP (serial)


Line 1 (E1) for Trunk

Port 1 for vlan 100, port 2 for vlan 101

Configure EoP (serial)


Interface EoP

Enable VCAT Enable LCAS

Save Configuration

Configure IP Management

Set IP address

IP Address

Subnet Mask

Vlan Management

Configure EoP
Login to RC953-4FEE1
Via Web Browser

IP : 192.168.4..30/24

Configure EoP (Web Browser)


Login to RC953-4FEE1

IP :192.168.4.28/24

User Name : raisecom Password : raisecom

Configure EoP (Web Browser)


Create Vlan
1 2 3

Configure EoP (Web Browser)


GFP Mode
1
2

3 4

Configure EoP (Web Browser)


Line 1 (E1) for Trunk
1

2 3

4
5

Configure EoP (Web Browser)


Port 1 for vlan 100, port 2 for vlan 101
1
2 3

5
4 6

Configure EoP (Web Browser)


VCG Member
1

Configure EoP (Web Browser)


Enable VCAT
1

2 3

Configure EoP (Web Browser)


Enable LCAS
1

2 3