Sunteți pe pagina 1din 12

ob. San.

E=
nr. Ob. =
tot. =

LV.

CHv.

WC.

CD.

0.35

1.00

0.50

1.00

0.70

0.00

1.00

0.00

ob. San.
Es =

LV.

CHv.

WCh.

WCsh.

CD.

0.50

1.00

3.50

6.00

1.00

nr. Ob. =
tot. =

0.00

0.00

0.00

0.00

0.00

Hotel/Hostel
Qcar =
Qcacm =

abc(sqrt sumE)

Qs=
Club/Bar
Qcar =
Qcacm =

Qs=

aEs

Es 1.5

abc(sqrt sumE)
a0.65(sqrt sumEs)

Es 0.50

aEs

Es 0.50

b[ac x (sqrt sumE) + 0.004 x sumE]


b[ac x (sqrt sumE) + 0.004 x sumE]
[a0.40(sqrt sumEs)]+(0.001Es)

Es 0.15

aEs

Es 0.15

Cladire de birouri/Admin
Qcar =
Qcacm =
Qs=

Es 1.5

abc(sqrt sumE)

Qs=
Locuinta
Qcar =
Qcacm =

abc(sqrt sumE)
a1.15(sqrt sumEs)

abc(sqrt sumE)
abc(sqrt sumE)
a0.70(sqrt sumEs)

Es 0.60

aEs

Es 0.60

Spital
Qcar =
Qcacm =

abc(sqrt sumE)
abc(sqrt sumE)

Qs(spital, restau=
rant, bufet)

a0.95(sqrt sumEs)

Es 1.00

aEs

Es 1.00

Calcul necesarului total de apa


nr. Pers.

nec. Total a.r. [l/zi]

4.00

680.00

Calcul ploaie

STAS 9470/73 plo


I9/2010-coeficient

Manualaul instalator
Manualaul instalatoru

Manualul inst

Bazin etans vidanjabil


Nr. Persoane =
Debit specific din STAS
1478/90[l/om &zi] =
Nr. zile =
V bazin etans vidanjabil =

0.00

Alegere Boiler
Q = m*c*t [Kw]

m [m3/h] *1000 [kg/h]/3600 [kg/s]


c [Kj/Kg*k] apa
t [K]
Q [Kj/s = Kw]

=
=
=
=

0.02
4.19
40.00
2.75

Hidranti interiori
nr.jeturi (P118-2/2013 ANEXA3, pag.164) =
debit/hidrant (P118-2/2013 ANEXA9, pag. 167 sau STAS
1478/90, pag. 11) [l/s] =
t [min.] =
Vhi [m3 =

Bazin de retentie
timp de concentrare superficala, tcs [min.] =
(1-3 min.) pentru zn. cu pante mai mari de 5%
(3-5 min.) pentru zn. de deal cu pante medii (1-5%)
(5-12 min.) pentru zn. de ses cu pante medii mai mici de 1 %

0.00

APA
CB.

SP.

MSv.

1.00

1.00

0.50

1.00

2.00

0.00

CANAL
CB.

SPs.

SPd.

SPc.

MSv.

2.00

1.00

1.50

0.50

2.00

0.00

0.00

0.00

0.00

0.00

a= 0.15
1.09

b= 1

0.90

c= 2.5

0.00

a= 0.33

0.00

a= 0.33
a= 0.15

0.54

b= 1

0.50

c= 1.4

0.00

a= 0.33

0.00

a= 0.33
a= 0.15

0.41

b= 1

0.38

c= 1

0.00

a= 0.33

0.00

a= 0.33
a= 0.15

0.61

b= 1

0.57

c= 1.6

0.00

a= 0.33

0.00

a= 0.33

a= 0.15
0.77

b= 1

0.72

c= 2

0.00

a= 0.33

0.00

a= 0.33

nec. Total a.c.m. [l/zi]


240.00

Qzimed [m3/zi]
0.75
0.26

Debite ape uzate


Qszimed [m3/zi]
0.75

Debite Ploaie

aria de pe care colectez


STAS 9470/73 ploi maxime-intensitatea ploii
I9/2010-coeficient functie de tipul suprafetei
debitul de ploaie

Si(m2)
Ii(l/s*ha)
(-)
Qcp(l/s)

=
=
=
=

PROPUN (se citesc din manualul in

nualaul instalatorului_debit la sectiune plina


nualaul instalatorului_viteza la sectiune plina
Manualul instalatorului
Manualul instalatorului_grad de umplere

0.00

Qsp (l/s) =
Vsp (m/s) =
x=
u (>0.5) =
z=
0.7 <Vr (m/s)<4 =

0.02
4.19
40.00
2.75

0.00

MSr.

PIS.

BID.

0.85

1.00

0.35

0.00

1.00

1
0.85

MSr.

PISi.

PISp.

BID.

2.00

3.50

0.15

0.50

0.00

0.00

0.00

0.00

Qzimax [m3/zi]

Qorarmax [m3/zi]

0.97
0.34

ape uzate
Qszimax [m3/zi]

0.12
0.04

Qsorarmax [m3/zi]

0.97

0.12

Ploaie
142.00
270.00
0.95
3.64

N (se citesc din manualul inst.)


#DIV/0!

0.00

sum Ear

sum Eacm

6.55

5.70

sum Es
0.00

S-ar putea să vă placă și