Localitate: CALARASI

0
tev =
37.5
C
=
23
%
Az =
7
Np =
1/6
m2
qsp =
w/m2
70
m2
Ldesen
L=
H=
4
m2
ql
0.055 kW
qom =
=
=
2.14023E-05
hv
2569.82
hv = cp * t + 2501 =
1.86 * 37 + 2501 =
2569.82
0
0
(t = 4 10) C
ti = tev - t
ti = 37.5 - 10 = 27.5 C
ti = (23 26)0C

Kg/s

Se adopta ti = 26 0C

G = Np * qom
v =
D=
tc = (6 8) 0C

Q [kW]
G [Kg/s]
Q [kW]
tc [0C]
se adopta 8 0C

Kg/s
=

Q [kW]
ti - tc [0C)

tc = ti - tc tc = ti - tc = 26 - 8 = 18 0C hc = 44 [KJ/Kg]
ti = 26 0C hi = 53 [KJ/Kg]
hi - hc = 9 [KJ/Kg]

Kg/s

m/s

Tab. 1.1. Calcul tabelar distributrie aer proaspat:


Nr.
Crt.
5.4

1
2
3
4
5
6
7
8
9

destinatia
Birou 1
Birou 2
Birou contorizare
Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

ti

Np

[0C]
26
26
26
26
26
26
26
26
26

[m]

[m2]
31.59
31.32
31.32
16.2
30.45
30.45
23.59
6.46
15.75

buc

[W]

[Kg/s]

[[KJ/Kg]

5
5
5
3
5
5
4
1
3

2211.30
2192.40
2192.40
1134.00
2131.50
2131.50
1651.30
452.38
1102.50

0.00010701
0.00010701
0.00010701
0.00006421
0.00010701
0.00010701
0.00008561
0.00002140
0.00006421

20664.2
20487.5
20487.5
17661.7
19918.4
19918.4
19288.8
21136.8
17171.1

S (rezultata)
m

S (reala)
m

0.025
0.047

[mm]
axh
125 x 200
240 x 200

0.025
0.048

v (reala)
m/s
6.60
6.88

5.85
5.80
5.80
3.00
5.80
5.80
5.80
2.75
3.00

Tab. 1.2. Dimensionare retea distributie aer:


m /h
594
1188

Nr.
Tr.
1
2

l/s
165.0
330.0

0.165
0.330

v (impusa)
m/s
6.50
7.00

1782

495.0

0.495

7.50

0.066

350 x 200

0.070

7.07

2632

731.0

0.731

8.00

0.091

460 x 200

0.092

7.95

3226

896.0

0.896

8.50

0.105

550 x 200

0.110

8.15

4075

1132.0

1.132

9.00

0.126

650 x 200

0.130

8.71

4925
5774
6624

7
8
9

1368.0
1604.0
1840.0

1.368
1.604
1.840

9.50
10.00
10.50

0.144
0.160
0.175

750 x 200
800 x 200
850 x 200

0.150
0.160
0.170

9.12
10.03
10.82

Debit
m/s

Tab. 1.3. Selectare unitati de climatizare tip ventilo-convectori:


Nr.
Tr.
1
2
3
4
5
6
7
8
9

destinatia
Birou 1
Birou 2
Birou contorizare
Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

Q
[KW]
2.21
2.19
2.19
1.13
2.13
2.13
1.65
0.45
1.10

Qsens
[KW]
2.81
2.17
2.17
1.61
2.17
2.17
1.61
1.61
1.61

Debit apa
l/h
m/h
666
0.666
524
0.524
524
0.524
373
0.373
524
0.524
524
0.524
373
0.373
373
0.373
373
0.373

Debit aer
m/h
610
445
445
380
445
445
380
380
380

tip. aparat
ELVIRA
ECM 32
ECM 22
ECM 22
ECM 12
ECM 22
ECM 22
ECM 12
ECM 12
ECM 12

Au fost selectati ventilo-convectori Elvira, tip caseta de plafon, cu 2 tevi, la o temperatura a apei 7 - 12 0C

Tab. 1.4. Dimensionarea conductelor pe distributia de agent termic si pierderile de sarcina aferente :
Debit
Qsens
Nr.
l/h
[l/s]
[KW]
Tr.
A. Distributia agentului termic pe ramura principala
1
373
0.104
1.61
2
746
0.207
2.71
3
1119
0.311
4.32
4
1643
0.456
6.49
5
2016
0.560
8.10
6
2540
0.706
10.27
7
3064
0.851
12.44
8
3730
1.036
15.25
9
4254
1.182
17.42
10
8508
2.363
34.85
Nota. Au fost selectate conducte de distributie din cupru.

[mm]

Rl

22 x 1,2
28 x 1.2
28 x 1.2
35 x 1.5
35 x 1.5
42 x 1.5
42 x 1.5
42 x 1.5
42 x 1.5
54 x 1,5

12.8
12.5
25
17.5
26
16
22
31
33
15

0.40
0.48
0.72
0.70
0.86
0.76
0.75
1.11
1.20
0.90

4.2
5.9
1.2
1.2
5.0
0.4
5.6
0.4
3.2
10.5

53.76
73.75
30
21
130
6.4
123.2
12.4
105.6
157.5

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Tronson 1
Nr.
crt.

1
2
3

Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept

buc.

1
2
2

2.5
3.5
0.7

2.5
7
1.4
10.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

TOTAL

Tronson 2
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
TOTAL

Tronson 3
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
TOTAL

Tronson 4
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
TOTAL

Tronson 5
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
TOTAL

Tronson 6
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.5

0.3
0.6
1
1.9

buc.

1
1
4

0.3
0.6
0.5

0.3
0.6
2

TOTAL

Tronson 7
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
TOTAL

Tronson 8
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
TOTAL

Tronson 9
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
3 robinet sferic
TOTAL

Tronson 10
Nr.
Denumire
crt.
1 teu trecere la separare
2 teu trecere la impreunare
3 robinet sferic

4
5
6

Cot drept
filtru "y"
schimbator de caldura in placi

6
1
1

0.6
2.5
3.5

3.6
2.5
3.5
12.5

TOTAL

Stabilirea inaltimii de pompare


HRR'

nec

Hpompa

nec

HRR'

nec

= 1,7 [mCA]

= (Rl+Z)c.c.m.d.

Determinarea pompei de circulatie - se face in functie de : ( Q

nom

nec

, HRR' )

Determinarea s-a facut folosind programul de selectie Willo cunoscand urmatoarele date:
- Debitul vehiculat: Q = 8,5 [m3/h]
- Inaltimea de pompare: H = 1,7 [mCA]
- Fluid de lucru: apa rece la temp. de 7 [0C]

In urma selectiei a rezultat o pompa marca Willo, Stratos-E 40/1-4 CAN, 230 [V], 50 [Hz], PN 10, cu turatie variabila, ava
- Debitul vehiculat: Q = 8,5 [m3/h]
- Inaltimea de pompare: H = 1,7 [mCA]

Dimensionarea hidraulica a circuitelor racordate in paralel cu circuitul cel mai defavorizat (c.c.m.d.)
Nr.
Tr.

Qsens
[KW]

Debit
l/h

[l/s]

[mm]

R
[mmcA/m]

v
[m/s]

l
[m]

Rl
[mmcA]

0.4
0.4
0.58

2.6
1.2
3.9

33.28
15.36
93.6

A. Dimensionare hidraulica pe tronsoanele legate in paralel cu c.c.m.d.


2.1
3.1
4.1

1.61
1.61
2.17

373
373
524

0.104
0.104
0.146

22 x 1.2
22 x 1.2
22 x 1.2

12.8
12.8
24

5.1
6.1
7.1
8.1
9.1

1.61
2.17
2.17
2.81
2.17

373
524
524
666
524

0.104
0.146
0.146
0.185
0.146

22 x 1.2
22 x 1.2
22 x 1.2
28 x 1.2
22 x 1.2

12.8
24
24
10
24

0.4
0.58
0.58
0.43
0.58

3.7
3.9
2.7
3.9
2.7

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Nr.
trons
on

2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1

Ventilo-convector
buc
1
1
1
1
1
1
1
1

Robinet cu ventil

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

buc
2
2
2
2
2
2
2
2

Cot drept

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

buc
2
2
2
2
2
2
2
2

Verificare conditie (Rl + Z)x = (Rl + Z)r si calcul HRech (Z*rob)


Nr.
tr.
2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1

(Rl +Z)x

(Rl +Z)r

[Pa]

[Pa]

Z* echilibrare
[Pa]

1204.8
1025.6
2778.1
1345.6
2778.1
2490.1
1392.8
2490.1

1409.6
2250.6
2784.6
3215.1
4925.5
5250.5
6736.8
7411.6

204.8
1225.0
6.5
1869.5
2147.4
2760.4
5344.0
4921.5

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9

47.36
93.6
64.8
39
64.8

Pentru a se realiza echilibrarea hidraulica a circuitelor legate in paralel se va


impune o pierdere de sarcina locala egala cu deficitul inregistrat pe fiecare
circuit in parte (Z*). Echilibrarea consta in manevrarea ventilului cu ventil si
scaun oblic montat pe fiecare consumator.

tip. aparat

[m3/h]
737.1
730.8
730.8
378.0
710.5
710.5
550.4
150.8
367.5

[l/s]

tip

204.8
203.0
203.0
105.0
197.4
197.4
152.9
41.9
102.1

606
606
606
505
606
606
505
505
505

v (impus) =(G/2)/(3.14*D2/4) =

debit
aparat

debit
aparat

[m3/h]
849.6
849.6
849.6
594
849.6
849.6
594
594
594

[l/s]

6.835

236
236
236
165
236
236
165
165
165

e:

Rl+Z

10.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
1.9
12.5

872
103.5
234
220.5
410.4
261
254.25
550.8
1425
5062.5

1409.6
841
534
430.5
1710.4
325
1486.25
674.8
2481
6637.5

(Rl+Z)

1409.6
2250.6
2784.6
3215.1
4925.5
5250.5
6736.75
7411.55
9892.55
16530.05

Z
80
115
260
245
456
290
282.5
612
750
405

u turatie variabila, avand urmatoarele caracteristici:

10.9
10.9
10.9

Z
[Pa]
872
872
1842.1

Rl+Z
[Pa]
1204.8
1025.6
2778.1

Z
80
80
169

10.9
10.9
10.9
10.9
10.9

872
1842.1
1842.1
1002.8
1842.1

1345.6
2778.1
2490.1
1392.8
2490.1

80
169
169
92
169

Localitate: ALEXANDRIA
0
tev =
C
38
=
Az =

25
7

m2
1/6
75
w/m2
Ldesen + 1 m2
L=
H=
4
m2
ql
0.055 kW
qom =
=
=
2.1402E-05
hv
2569.82
hv = cp * t + 2501 = 1.86 * 37 + 2501 =
2569.82
0
(t = 4 10) C
ti = tev - t
ti = 38 - 10 = 28 0C
Np =
qsp =

ti = (23 26) C

Se adopta ti = 26 C

G = Np * qom
Q [kW]
v=
G [Kg/s]
Q [kW]
D=
tc [0C]

tc = (6 8) C

Kg/s
Q [kW]
ti - tc [0C)

Kg/s

se adopta 8 C

m/s

m3/h
850
1699
2293
3481

tc = ti - tc tc = ti - tc = 26 - 8 = 18 C hc = 32 [KJ/Kg]
0

Kg/s

4669

ti = 26 C hi = 39 [KJ/Kg]

5857

hi - hc = 7 [KJ/Kg]

7045
8233
9421

1
2
3
4
5
6
7
8
9

A. Dimensionar
1
2
3
4
5
6
7
8
9
10

Nr.
crt.

1
2
3

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2

Nr.
crt.
1
2
3
4
5

Stabilirea ina
HRR'

nec

Hp

HRR'

nec

= 1,9

Determinarea s

In urma selecti

Dimensionare

A. Dimensionar
2.1
3.1
4.1
5.1

6.1
7.1
8.1
9.1

2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1

2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1

Tab. 1.1. Calcul tabelar distributrie aer proaspat:


Nr.
Crt.

destinatia

1
2
3

Birou 1
Birou 2

Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

5
6
7
8
9

Birou contorizare

ti

Np

[0C]
26
26
26

[m]
6.85
6.80
6.80

[m2]
36.99
36.72
36.72

buc
6
6
6

[W]
2774.25
2754.00
2754.00

[Kg/s]
0.00012841
0.00012841
0.00012841

[[KJ/Kg]
21604.01
21446.32
21446.32

[m3/h]
1189.0
1180.3
1180.3

[l/s]
330.3
327.9
327.9

26

4.00

21.6

1620.00

0.00008561

18923.22

694.3

192.9

26
26
26
26
26

6.80
6.80
6.80
2.75
4.00

35.7
35.7
28.84
6.46
21.00

6
6
5
1
4

2677.50
2677.50
2163.00
484.69
1575.00

0.00012734
0.00012734
0.00010701
0.00002140
0.00007491

21025.8
21025.8
20212.8
22646.54
21025.8

1147.5
1147.5
927.0
207.7
675.0

318.8
318.8
257.5
57.7
187.5

S (reala)
0.038
0.069

v (reala)
m/s
6.29
6.87

Tab. 1.2. Dimensionare retea distributie aer:


Debit

v (impusa) S (rezultata) [mm]


m
m/s
axh
6.50
0.036
150 x 250
7.00
0.067
275 x 250

Nr. Tr.
1
2

l/s
236.0
472.0

m/s
0.236
0.472

3
4

637.0
967.0

0.637
0.967

7.50
8.00

0.085
0.121

340 x 250
480 x 250

0.085
0.120

7.49
8.06

1297.0

1.297

8.50

0.153

600 x 250

0.150

8.65

1627.0

1.627

9.00

0.181

725 x 250

0.181

8.98

7
8
9

1957.0
2287.0
2617.0

1.957
2.287
2.617

9.50
10.00
10.50

0.206
0.229
0.249

825 x 250
900 x 250
975 x 250

0.206
0.225
0.244

9.49
10.16
10.74

Tab. 1.3. Selectare unitati de climatizare tip ventilo-convectori:

v (impus) =(G/2)/(3.14*D /4) =

Nr. Tr.
1
2
3
4
5
6
7
8
9

destinatia
Birou 1
Birou 2
Birou contorizare
Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

Q
[KW]
2.77
2.75
2.75
1.62
2.68
2.68
2.16
0.48
1.58

Qsens
[KW]
2.87
2.87
2.87
2.02
2.87
2.87
2.02
1.03
2.02

Debit apa
l/h
670
670
670
450
670
670
450
220
450

m/h
0.67
0.67
0.67
0.45
0.67
0.67
0.45
0.22
0.45

Debit aer
m/h

tip. aparat
ADELIA
1200 x 600
1200 x 600
1200 x 600
900 x 600
1200 x 600
1200 x 600
900 x 600
600 x 600
900 x 600

VCV - caseta liniara, de plafon (2 tevi), t. apa

Au fost selectati ventilo-convectori Adelia, tip caseta liniara de plafon, cu 2 tevi, la o temperatura a apei 7 - 12 C

Dimensionarea hidraulica a circuitului cel mai defavorizat (c.c.m.d.).


Nr. Tr.

Qsens
[KW]

Debit
[m3/h]

[mm]

Rl

Rl+Z

4.2
6.3
1.3
1.0
6.0
1.0
6.1
1.0
3.3
10.5

151.2
201.6
16.25
9.6
78
22
73.2
16
62.7
231

10.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
1.9
12.5

2201.8
179.55
90
103.5
147.15
261
162
240.75
624.15
6250

3713.8
2195.55
252.5
199.5
927.15
481
894
400.75
1251.15
8560

A. Dimensionare hidraulica pe tronsoanele legate in paralel cu c.c.m.d.


1
0.450
2.02
15
2
0.900
3.60
20
3
1.120
4.63
25
4
1.790
7.50
32
5
2.240
9.52
32
6
2.910
12.39
32
7
3.580
15.26
40
8
4.250
18.13
40
9
4.920
21.00
40
10
9.840
41.99
50
Nota. Au fost selectate conducte de distributie din PVC.

36
32
12.5
9.6
13
22
12
16
19
22

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Tronson 1

0.54
0.63
0.45
0.48
0.57
0.76
0.60
0.73
0.81
1.00

Nr.
crt.

1
2
3

Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

buc.

1
2
2

2.5
3.5
0.7

2.5
7
1.4
10.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

Tronson 2
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 3
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 4
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 5
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 6

Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.5

0.3
0.6
1
1.9

buc.

1
1
4
6
1

0.3
0.6
0.5
0.6
2.5

0.3
0.6
2
3.6
2.5

TOTAL

Tronson 7
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 8
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 9
Nr.
crt.
1
2

Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
TOTAL

Tronson 10
Nr.
crt.
1
2
3
4
5

Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
Cot drept
filtru "y"

schimbator de caldura in placi


TOTAL

3.5

3.5
12.5

Stabilirea inaltimii de pompare


HRR'

nec

Hpompa

nec

HRR'

nec

= 1,9 [mCA]

= (Rl+Z)c.c.m.d.

Determinarea pompei de circulatie - se face in functie de : ( Q

nom

nec

, HRR' )

Determinarea s-a facut folosind programul de selectie Willo cunoscand urmatoarele date:
- Debitul vehiculat: Q = 9,84 [m3/h]
- Inaltimea de pompare: H = 1,9 [mCA]
0
- Fluid de lucru: apa rece la temp. de 7 [ C]

In urma selectiei a rezultat o pompa marca Willo, Stratos-E 50/1-8 CAN, 230 [V], 50 [Hz], PN 10, cu turatie variabila, avand urmatoarele ca
- Debitul vehiculat: Q = 8,5 [m3/h]
- Inaltimea de pompare: H = 1,7 [mCA]

Dimensionarea hidraulica a circuitelor racordate in paralel cu circuitul cel mai defavorizat (c.c.m.d.)
Nr. Tr.

Qsens
[KW]

Debit
3
[m /h]

[mm]

Rl

Rl+Z

2.6
1.2
3.9
3.7

93.6
15
70.2
133.2

10.9
10.9
10.9
10.9

1602.3
457.8
1253.5
1602.3

2538.3
607.8
1955.5
2934.3

A. Dimensionare hidraulica pe tronsoanele legate in paralel cu c.c.m.d.


2.1
3.1
4.1
5.1

2.02
1.03
2.87
2.02

0.450
0.220
0.670
0.450

15
15
20
15

36
12.5
18
36

0.54
0.29
0.48
0.54

6.1
7.1
8.1
9.1

2.87
2.87
2.87
2.87

0.670
0.670
0.670
0.670

20
20
20
20

18
18
18
18

0.48
0.48
0.48
0.48

3.9
2.7
3.9
2.7

70.2
48.6
70.2
48.6

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Nr.
tronso
n

2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1

Ventilo-convector
buc
1
1
1
1
1
1
1
1

Robinet cu ventil

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

buc
2
2
2
2
2
2
2
2

Cot drept

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

buc
2
2
2
2
2
2
2
2

Verificare conditie (Rl + Z)x = (Rl + Z)r si calcul HRech (Z*rob)


Nr. tr.
2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1

(Rl +Z)x

(Rl +Z)r

[Pa]

[Pa]

Z* echilibrare
[Pa]

2538.3
607.8
1955.5
2934.3
1955.5
1739.5
1955.5
1739.5

3713.8
5909.4
6161.9
6361.4
7288.5
7769.5
8663.5
9064.3

1175.5
5301.6
4206.4
3427.1
5333.0
6030.0
6708.0
7324.8

0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9

10.9
10.9
10.9
10.9

1253.5
1253.5
1253.5
1253.5

1955.5
1739.5
1955.5
1739.5

Pentru a se realiza echilibrarea hidraulica a circuitelor legate in paralel


se va impune o pierdere de sarcina locala egala cu deficitul inregistrat
pe fiecare circuit in parte (Z*). Echilibrarea consta in manevrarea
ventilului cu ventil si scaun oblic montat pe fiecare consumator.

tip. aparat

debit
aparat

tip
707
707
707

[m3/h]
1188
1188
1188

debit
aparat
[l/s]
330
330
330

606

849.6

236

707
707
707
505
606

1188
1188
1188
594
849.6

330
330
330
165
236

=(G/2)/(3.14*D /4) =

6.771

ta liniara, de plafon (2 tevi), t. apa 7-120C

(Rl+Z)

3713.8
5909.35
6161.85
6361.35
7288.5
7769.5
8663.5
9064.25
10315.4
18875.4

Z
202
199.5
100
115
163.5
290
180
267.5
328.5
500

ariabila, avand urmatoarele caracteristici:

Z
147
42
115
147

115
115
115
115

Tab. 1.1. Calcul tabelar


Localitate:
tev =

Nr. Crt.

=
Az =

32.8
35
6

Np =
qsp =

1/5
65

m2

L=

C
%

1
2
3

w/m2
2
Ldesen + 0.5 m

4
5

m
4
ql
0.055 kW
qom =
=
=
2.1402E-05
hv
2569.82
hv = cp * t + 2501 = 1.86 * 37 + 2501 =
2569.82
0
0
(t
=
4

10)
C
ti = tev - t
ti = 32.8 - 10 = 26.5 C
H=

ti = (23 26)0C

6
7
8
9

Kg/s

Se adopta ti = 26 0C

G = Np * qom
Q [kW]
Kg/s
v=
G [Kg/s]
Q [kW]
D=
=
0
tc [ C]
tc = (6 8) 0C
se adopta 8 0C

Q [kW]
0
ti - tc [ C)

Kg/s

m/s

m /h
594
1188
1782

Nr. Tr.
1
2

2632

3
4

3226

ti = 26 C hi = 38 [KJ/Kg]

4075

hi - hc = 9 [KJ/Kg]

4925
5774
6624

7
8
9

tc = ti - tc tc = ti - tc = 26 - 8 = 18 C hc = 29 [KJ/Kg]
0

Nr. Tr.
1
2
3
4
5
6
7
8
9

Au fost selectati ventilo-convecto


la o temperatura a apei 7 - 120C

Dimensionarea hidraulica
Nr. Tr.

A. Dimensionare hidraulica a

1
2
3
4
5
6
7
Nota. Au fost selectate conducte

CALCULUL PIERDERILOR D
Tronson 1
Nr. crt.

1
2
3

Tronson 2
Nr. crt.
1
2

Tronson 3
Nr. crt.
1
2

Tronson 4
Nr. crt.
1
2

Tronson 5
Nr. crt.
1
2

Tronson 6

Nr. crt.
1
2

Tronson 7
Nr. crt.
1
2
3
4
5
6

Stabilirea inaltimii de pom

HRR'nec Hpompanec = (Rl


HRR'nec = 2,3 [mCA]

Determinarea pompei de c

Determinarea s-a facut folos

In urma selectiei a rezultat o

Dimensionarea hidraulica
Nr. Tr.

B. Dimensionare hidraulica pe
7.41
7.4
7.3
7.2
7.1
2.1
3.1
4.1
7.5
7.31
7.21
7.11

CALCULUL PIERDERILOR D
Tronson 7.5
Nr. crt.

1
2
3

Tronson 7.4
Nr. crt.
1
2

Tronson 7.3
Nr. crt.
1
2

Tronson 7.2
Nr. crt.
1
2

Tronson 7.1
Nr. crt.
1
2

Tronson 2.1
Nr. crt.

1
2
3

Tronson 3.1
Nr. crt.

1
2
3

Tronson 4.1
Nr. crt.

1
2
3

Tronson 7.41
Nr. crt.

1
2
3

Tronson 7.31
Nr. crt.

1
2
3

Tronson 7.21

Nr. crt.

1
2
3

Tronson 7.11
Nr. crt.

1
2
3

Nr. tr.
2.1
3.1
4.1
7.1
7.5
7.31
7.21
7.11

Tab. 1.1. Calcul tabelar distributrie aer proaspat:


ti

Np

[0C]
26
26
26

[m]
6.35
6.30
6.30

[m2]
33.34
33.08
33.08

buc
7
7
7

[W]
2166.94
2149.88
2149.88

Birou S5 Apa
Birou Tehnic 1

26

3.50

18.38

26

6.30

33.08

Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

26
26
26
26

6.30
6.30
2.75
3.50

33.08
26.22
6.46
18.38

destinatia
Birou 1
Birou 2
Birou contorizare

tip. aparat

[Kg/s]
[[KJ/Kg]
0.00014982 14464.0
0.00014982 14350.1
0.00014982 14350.1

[m3/h]
722.3
716.6
716.6

[l/s]
200.6
199.1
199.1

tip
606
606
606

1194.38

0.00008561 13951.5

398.1

110.6

505

2149.88

0.00014982 14350.1

716.6

199.1

606

7
5
1
4

2149.88
1703.98
420.06
1194.38

0.00014982
0.00010701
0.00002140
0.00008561

716.6
568.0
140.0
398.1

199.1
157.8
38.9
110.6

606
505
505
505

S (reala)
0.025
0.048

v (reala)
m/s
6.60
6.88

14350.1
15923.3
19627.0
13951.5

Tab. 1.2. Dimensionare retea distributie aer:


Debit

v (impusa) S (rezultata) [mm]


m
m/s
axh
6.50
0.025
125 x 200
7.00
0.047
240 x 200

l/s
165.0
330.0

m/s
0.165
0.330

495.0
731.0

0.495
0.731

7.50
8.00

0.066
0.091

350 x 200
450 x 200

0.070
0.090

7.07
8.12

896.0

0.896

8.50

0.105

525 x 200

0.105

8.53

1132.0

1.132

9.00

0.126

625 x 200

0.125

9.06

1368.0
1604.0
1840.0

1.368
1.604
1.840

9.50
10.00
10.50

0.144
0.160
0.175

725 x 200
800 x 200
850 x 200

0.145
0.160
0.170

9.43
10.03
10.82

Tab. 1.3. Selectare unitati de climatizare tip ventilo-convectori:

v (impus) =(G/2)/(3.14*D2/4) =

destinatia
Birou 1
Birou 2
Birou contorizare
Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

Q
[KW]
2.17
2.15
2.15
1.19
2.15
2.15
1.70
0.42
1.19

Qsens
[KW]
2.34
2.34
2.34
1.45
2.34
2.34
1.82
1.20
1.20

Debit apa
l/h
m/h
535
0.535
535
0.535
535
0.535
250
0.250
535
0.535
535
0.535
400
0.400
210
0.210
210
0.210

Debit aer tip. aparat


H-silence
m/h
480
HS 3.4
480
HS 3.4
480
HS 3.4
240
HS 1.4
480
HS 3.4
480
HS 3.4
360
HS 2.4
240
HS 1.3
240
HS 1.3

VCV - carcasat de pardoseala (2 tevi, 3 randuri x.3 si 4

Au fost selectati ventilo-convectori Hegoa Silence, tip necarcasati de plafon, cu 2 tevi, 3 si 4 randuri,
la o temperatura a apei 7 - 120C

Dimensionarea hidraulica a circuitului cel mai defavorizat (c.c.m.d.).


Qsens
[KW]

Debit
3
m /h

[mm]

Rl

Rl+Z

0.38
0.73
0.56
0.87
0.96
0.86
0.97

8.00
6.45
6.45
6.45
12.00
0.05
2.50

128
167.7
96.75
212.85
324
0.9
57.5

13.7
0.9
0.9
1.9
0.9
0.9
12.5

2315.3
162
202.5
841.7
565.2
364.5
8275

3595.3
1839.0
1170.0
2970.2
3805.2
373.5
8850.0

(Rl+Z)

A. Dimensionare hidraulica a c.c.m.d. (tronsoanele 1, 2, 3, 4, 5, 6 si 7)


0.250
1.45
1/2"
0.785
3.79
3/4"
1.320
6.13
1"
1.855
8.47
1"
3.710
16.94
1 1/4"
5.600
25.84
40
7.490
34.74
40
Nota. Au fost selectate conducte de distributie din otel.

16
26
15
33
27
18
23

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Tronson 1
Denumire

buc.

3595.3
5434.3
6604.3
9574.5
13379.7
13753.2
22603.2

ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.5

0.3
0.6
1
1.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

Tronson 2
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 3
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 4
Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
TOTAL

Tronson 5
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 6

Denumire
teu trecere la separare
teu trecere la impreunare

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1
4
6
1
1

0.3
0.6
0.5
0.6
2.5
3.5

0.3
0.6
2
3.6
2.5
3.5
12.5

TOTAL

Tronson 7
Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
Cot drept
filtru "y"
schimbator de caldura in placi
TOTAL

Stabilirea inaltimii de pompare


HRR'nec Hpompanec = (Rl+Z)c.c.m.d.
HRR'nec = 2,3 [mCA]
Determinarea pompei de circulatie - se face in functie de : ( Qnom, HRR'nec)
Determinarea s-a facut folosind programul de selectie Willo cunoscand urmatoarele date:
- Debitul vehiculat: Q = 7,49 [m3/h]
- Inaltimea de pompare: H = 2,3 [mCA]
- Fluid de lucru: apa rece la temp. de 7 [0C]

In urma selectiei a rezultat o pompa marca Willo, Stratos-E 40/1-4 CAN, 230 [V], 50 [Hz], PN 10, cu turatie variabila, avand urmatoarele caracteri

- Debitul vehiculat: Q = 7,49 [m /h]


- Inaltimea de pompare: H = 2,3 [mCA]

Dimensionarea hidraulica a circuitelor racordate in paralel cu circuitul cel mai defavorizat (c.c.m.d.)
Qsens
[KW]

Debit
m3/h

[mm]

Rl

Rl+Z

0.33
0.34
0.6
0.6
0.89
0.4
0.4
0.4
0.33
0.33
0.4
0.4

8.20
2.60
6.45
6.45
4.00
0.40
0.40
0.40
5.30
0.40
0.40
0.40

98.40
20.80
148.35
112.88
144.00
5.20
5.20
5.20
63.60
3.00
5.20
5.20

13.7
0.9
0.9
0.9
1.9
13.7
13.7
13.7
13.7
13.7
13.7
13.7

748.02
52.02
162
162
763.8
1096
1096
1096
748.02
748.02
1096
1096

1732.02
260.02
1645.5
1290.75
2203.8
1148
1148
1148
1384.02
778.02
1148
1148

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

(Rl+Z)

B. Dimensionare hidraulica pe tronsoanele legate in paralel cu c.c.m.d.


1.20
2.40
4.22
6.56
8.90
2.34
2.34
2.34
1.20
1.82
2.34
2.34

0.210
0.420
0.820
1.355
1.890
0.535
0.535
0.535
0.210
0.400
0.535
0.535

1/2"
1/2"
3/4"
3/4"
1"
3/4"
3/4"
3/4"
1/2"
3/4"
3/4"
3/4"

12
8
23
17.5
36
13
13
13
12
7.5
13
13

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Tronson 7.5
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

1732.02
1992.04
3637.54
4928.29
7132.09
1148
1148
1148
1384.02
778.02
1148
1148

Tronson 7.4
Denumire
teu trecere la separare
teu trecere la impreunare

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.3
0.6
0.9

buc.

1
1

0.3
0.6

0.5

0.3
0.6
1
1.9

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2

TOTAL

Tronson 7.3
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 7.2
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 7.1
Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
TOTAL

Tronson 2.1
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept

TOTAL

13.7

Tronson 3.1
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

Tronson 4.1
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.41
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.31
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.21

Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

Tronson 7.11
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Verificare conditie (Rl + Z)x = (Rl + Z)r si calcul HRech (Z*rob)


(Rl +Z)x

(Rl +Z)r

[Pa]

[Pa]

Z* echilibrare
[Pa]

3595.3
2447.3
1148
5434.3
4286.3
1148
6604.3
5456.3
1148
13753.2
6621.1
7132.09
1732.0
348.0
1384.02
1992.0
1214.0
778.02
3637.5
2489.5
1148
4928.3
3780.3
1148
Pentru a se realiza echilibrarea hidraulica a circuitelor legate in paralel

debit
aparat
[m3/h]
849.6
849.6
849.6

debit
aparat
[l/s]
236
236
236

594

165

849.6

236

849.6
594
594
594

236
165
165
165

6.835

ardoseala (2 tevi, 3 randuri x.3 si 4 randuri x.4) apa 7-120C

Z
169
180
225
443
628
405
662

, avand urmatoarele caracteristici:

Z
54.6
57.8
180
180
402
80
80
80
54.6
54.6
80
80

Tab. 1.1. Calcu


Localitate: CRAIOVA
0
C
tev =
36.5
=
35
%
Az =
7

Nr. Crt.
1
2
3

m
1/6
75
w/m2
Ldesen + 0.5 m2
L=
H=
4
m2
ql
0.055 kW
qom =
=
=
2.1402E-05
hv
2569.82
hv = cp * t + 2501 = 1.86 * 37 + 2501 =
2569.82
0
0
(t = 4 10) C
ti = tev - t
ti = 36.5 - 10 = 26.5 C
Np =
qsp =

ti = (23 26) C

4
5
6
7
8
9

Kg/s

Se adopta ti = 26 C

G = Np * qom
Q [kW]
Kg/s
v=
G [Kg/s]
Q [kW]
D=
=
tc [0C]
0
0
tc = (6 8) C
se adopta 8 C

Q [kW]
ti - tc [0C)

Kg/s

m/s

m3/h
594
1188
1782

Nr. Tr.
1
2

2632

3
4

3481

ti = 26 C hi = 53 [KJ/Kg]

4331

hi - hc = 9 [KJ/Kg]

5180
6030
6880

7
8
9

tc = ti - tc tc = ti - tc = 26 - 8 = 18 C hc = 44 [KJ/Kg]
0

Nr. Tr.
1
2
3
4
5
6
7
8
9

Au fost selectati ventilola o temperatura a apei

Dimensionarea hidr
Nr. Tr.

A. Dimensionare hidra

1
2
3
4
5
6
7
Nota. Au fost selectate c

CALCULUL PIERDER
Tronson 1
Nr. crt.

1
2
3

Tronson 2
Nr. crt.
1
2

Tronson 3
Nr. crt.
1
2

Tronson 4
Nr. crt.
1
2

Tronson 5
Nr. crt.
1
2

Tronson 6
Nr. crt.
1
2

Tronson 7
Nr. crt.
1
2
3
4
5
6

Stabilirea inaltimii

HRR'nec Hpompanec

HRR'nec = 2,4 [mCA

Determinarea pomp

Determinarea s-a fac

In urma selectiei a re

Dimensionarea hidr
Nr. Tr.

A. Dimensionare hidra
7.5
7.4
7.3
7.2
7.1
2.1
3.1
4.1
7.41
7.31
7.21
7.11

CALCULUL PIERDER
Tronson 7.5
Nr. crt.

1
2
3

Tronson 7.4
Nr. crt.
1
2

Tronson 7.3
Nr. crt.
1
2

Tronson 7.2
Nr. crt.
1
2

Tronson 7.1
Nr. crt.
1
2

Tronson 2.1
Nr. crt.

1
2
3

Tronson 3.1
Nr. crt.

1
2
3

Tronson 4.1
Nr. crt.

1
2
3

Tronson 7.41
Nr. crt.

1
2
3

Tronson 7.31
Nr. crt.

1
2
3

Tronson 7.21
Nr. crt.

1
2
3

Tronson 7.11
Nr. crt.

1
2
3

Verificare conditie (
Nr. tr.
2.1
3.1
4.1
7.1
7.41
7.31
7.21
7.11

Tab. 1.1. Calcul tabelar distributrie aer proaspat:


destinatia
Birou 1
Birou 2
Birou contorizare
Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

ti

Np

tip. aparat

[0C]
26
26
26

[m]
6.50
6.30
6.30

[m2]
34.13
33.08
33.08

buc
6
6
6

[W]
2559.38
2480.63
2480.63

[Kg/s]
0.00012841
0.00012841
0.00012841

[[KJ/Kg]
19930.71
19317.45
19317.45

[m3/h]
853.1
826.9
826.9

[l/s]
237.0
229.7
229.7

tip
606
606
606

26

3.50

18.38

1378.13

0.00006421

21463.84

459.4

127.6

505

26
26
26
26
26

6.30
6.30
6.30
2.75
3.50

33.08
33.08
26.22
6.46
18.38

6
6
5
1
3

2480.63
2480.63
1966.13
484.69
1378.13

0.00012841
0.00012841
0.00010701
0.00002140
0.00006554

19317.45
19317.45
18373.04
22646.54
21025.8

826.9
826.9
655.4
161.6
459.4

229.7
229.7
182.0
44.9
127.6

606
606
606
505
505

S (rezultata)

S (reala)

0.025
0.047

[mm]
axh
130 x 200
240 x 200

0.026
0.048

v (reala)
m/s
6.35
6.88

Tab. 1.2. Dimensionare retea distributie aer:


Debit
l/s
165.0
330.0

m/s
0.165
0.330

v (impusa)
m/s
6.50
7.00

495.0
731.0

0.495
0.731

7.50
8.00

0.066
0.091

325 x 200
450 x 200

0.065
0.090

7.62
8.12

967.0

0.967

8.50

0.114

560 x 200

0.112

8.63

1203.0

1.203

9.00

0.134

660 x 200

0.132

9.11

1439.0
1675.0
1911.0

1.439
1.675
1.911

9.50
10.00
10.50

0.151
0.168
0.182

750 x 200
850 x 200
900 x 200

0.150
0.170
0.180

9.59
9.85
10.62

Tab. 1.3. Selectare unitati de climatizare tip ventilo-convectori:

v (impus) =(G/2)/(3.14*D2/4) =

destinatia
Birou 1
Birou 2
Birou contorizare
Birou S5 Apa
Birou Tehnic 1
Birou Tehnic 2
Birou Auto
Oficiu Portar
Birou CAB

Q
[KW]
2.56
2.48
2.48
1.38
2.48
2.48
1.97
0.48
1.38

Qsens
[KW]
2.68
2.68
2.68
1.67
2.49
2.49
2.35
1.00
1.67

Debit apa
l/h
595
595
595
370
570
570
500
225
370

m/h
0.595
0.595
0.595
0.37
0.57
0.57
0.5
0.225
0.37

Debit aer
m/h
600
600
600
360
480
480
480
240
360

tip. aparat
HEGOA
H 4.3
H 4.3
H 4.3
H 2.3
H 3.4
H 3.4
H 3.3
H 1.3
H 2.3

VCV - carcasat de pardoseala (2 tevi, 3 randuri x.3

Au fost selectati ventilo-convectori Hegoa, tip carcasati de pardoseala, cu 2 tevi, 3 si 4 randuri,


la o temperatura a apei 7 - 120C

Dimensionarea hidraulica a circuitului cel mai defavorizat (c.c.m.d.).


Qsens
[KW]

Debit
l/h

[l/s]

[mm]

v
[m/s]

l
[m]

Rl
[mmcA]

Z
[Pa]

Rl+Z
[Pa]

32
17.5
17
30
32
15
23

0.58
0.60
0.67
0.94
1.12
0.90
1.15

8.00
6.45
6.45
6.45
12.00
0.05
2.50

256.00
112.88
109.65
193.50
384.00
0.75
57.50

13.7
0.9
0.9
1.9
0.9
0.9
12.5

2315.3
162
202.5
841.7
565.2
364.5
8275

4875.3
1290.8
1299.0
2776.7
4405.2
372.0
8850.0

R
[mmcA/m]

A. Dimensionare hidraulica a c.c.m.d. (tronsoanele 1, 2, 3, 4, 5, 6 si 7)


370
0.103
1.67
965
0.268
4.35
1560
0.433
7.03
2155
0.599
9.71
4310
1.197
19.42
6545
1.818
29.42
8780
2.439
39.42
Nota. Au fost selectate conducte de distributie din cupru.

18 x 1
28 x 1,2
35 x 1.5
35 x 1.5
42 x 1.5
54 x 1.5
54 x 1.5

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Tronson 1
Denumire

buc.

ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
1

0.3
0.6

0.3
0.6
0.9

buc.
1
1

0.3
0.6

0.3
0.6
0.9

buc.
1
1

0.3
0.6

0.5

0.3
0.6
1
1.9

buc.
1
1

0.3
0.6

0.3
0.6
0.9

buc.
1
1

0.3
0.6

0.3
0.6

Tronson 2
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 3
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 4
Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
TOTAL

Tronson 5
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 6
Denumire
teu trecere la separare
teu trecere la impreunare

TOTAL

0.9

Tronson 7
Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
Cot drept
filtru "y"
schimbator de caldura in placi
TOTAL

buc.
1
1
4
6
1
1

0.3
0.6
0.5
0.6
2.5
3.5

0.3
0.6
2
3.6
2.5
3.5
12.5

Stabilirea inaltimii de pompare


HRR'nec Hpompanec = (Rl+Z)c.c.m.d.
HRR'nec = 2,4 [mCA]
Determinarea pompei de circulatie - se face in functie de : ( Qnom, HRR'nec)
Determinarea s-a facut folosind programul de selectie Willo cunoscand urmatoarele date:
- Debitul vehiculat: Q = 8780 [l/h] = 8,78 [m3/h]
- Inaltimea de pompare: H = 2,4 [mCA]
- Fluid de lucru: apa rece la temp. de 7 [0C]

In urma selectiei a rezultat o pompa marca Willo, Stratos 40/1-8 CAN, 230 [V], 50 [Hz], PN 10, cu turatie variabila, avand urmatoarele caracteristic
- Debitul vehiculat: Q = 2,4 [m3/h]
- Inaltimea de pompare: H = 8,78 [mCA]

Dimensionarea hidraulica a circuitelor racordate in paralel cu circuitul cel mai defavorizat (c.c.m.d.)
Qsens
[KW]

Debit
l/h

[l/s]

v
[m/s]

l
[m]

Rl
[mmcA]

Z
[Pa]

Rl+Z
[Pa]

32
27
23
18
13
27
27
27
13
24
26
26

0.58
0.62
0.7
0.7
0.67
0.62
0.62
0.62
0.38
0.58
0.61
0.61

5.30
2.60
6.45
6.45
4.00
0.40
0.40
0.40
8.20
0.40
0.40
0.40

169.60
70.20
148.35
116.10
52.00
10.80
10.80
10.80
106.60
9.60
10.40
10.40

13.7
0.9
0.9
0.9
1.9
13.7
13.7
13.7
13.7
13.7
13.7
13.7

2315.3
173.7
222.3
220.5
427.5
2644.1
2644.1
2644.1
890.5
2315.3
2555.05
2555.05

4011.3
875.7
1705.8
1381.5
947.5
2752.1
2752.1
2752.1
1956.5
2411.3
2659.05
2659.05

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
1

0.3
0.6

0.3
0.6

[mm]

R
[mmcA/m]

A. Dimensionare hidraulica pe tronsoanele legate in paralel cu c.c.m.d.


1.67
2.67
5.02
7.51
10.00
2.68
2.68
2.68
1.00
2.35
2.49
2.49

370
595
1095
1665
2235
595
595
595
225
500
570
570

0.103
0.165
0.304
0.463
0.621
0.165
0.165
0.165
0.063
0.139
0.158
0.158

18 x 1
22 x 1.2
28 x 1.2
35 x 1.5
42 x 1.5
22 x 1.2
22 x 1.2
22 x 1.2
18 x 1
22 x 1.2
22 x 1.2
22 x 1.2

CALCULUL PIERDERILOR DE SARCINA PE TRONSOANE


Tronson 7.5
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.4
Denumire
teu trecere la separare
teu trecere la impreunare

TOTAL

0.9

Tronson 7.3
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

buc.
1
1

0.3
0.6

0.3
0.6
0.9

buc.
1
1

0.3
0.6

0.3
0.6
0.9

buc.
1
1

0.3
0.6

0.5

0.3
0.6
1
1.9

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

Tronson 7.2
Denumire
teu trecere la separare
teu trecere la impreunare
TOTAL

Tronson 7.1
Denumire
teu trecere la separare
teu trecere la impreunare
robinet sferic
TOTAL

Tronson 2.1
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 3.1
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 4.1
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2
13.7

buc.
1
2
6

2.5
3.5
0.7

2.5
7
4.2

Tronson 7.41
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.31
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.21
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept
TOTAL

Tronson 7.11
Denumire
ventilo-convector
Robinet cu ventil si scaun oblic
Cot drept

TOTAL

13.7

Verificare conditie (Rl + Z)x = (Rl + Z)r si calcul HRech (Z*rob)


(Rl +Z)x

(Rl +Z)r

[Pa]

[Pa]

Z* echilibrare
[Pa]

2752.1
2752.1
2752.1
8921.8
1956.5
2411.3
2659.05
2659.05

4875.3
6166.1
7465.1
15019.0
4011.3
4887.0
6592.8
7974.3

2123.2
3414.0
4713.0
6097.2
2054.8
2475.7
3933.8
5315.3

Pentru a se realiza echilibrarea hidraulica a circuitelor legate in paralel se


va impune o pierdere de sarcina locala egala cu deficitul inregistrat pe
fiecare circuit in parte (Z*). Echilibrarea consta in manevrarea ventilului
cu ventil si scaun oblic montat pe fiecare consumator.

debit
aparat
[m3/h]
849,6
849.6
849.6

debit
aparat
[l/s]
236
236
236

594

165

849.6
849.6
849.6
594
594

236
236
236
165
165

6.835

pardoseala (2 tevi, 3 randuri x.3 si 4 randuri x.4) apa 7-120C

(Rl+Z)
[Pa]

Z
4875.3
6166.1
7465.1
10241.8
14647.0
15019.0
23869.0

169
180
225
443
628
405
662

d urmatoarele caracteristici:

(Rl+Z)
[Pa]
4011.3
4887
6592.8
7974.3
8921.8
2752.1
2752.1
2752.1
1956.5
2411.3
2659.05
2659.05

Z
169
193
247
245
225
193
193
193
65
169
186.5
186.5

S-ar putea să vă placă și