CATALOG NALT TENSIUNE

HIGH VOLTAGE CATALOG


CUPRINS
SUMMARY

Introducere 2
Introduction 3

Intreruptor in SF6 123 kV 4


123 kV SF6 Circuit Breaker 4

Transformator de msur de tensiune 123 kV 6


123 kV Voltage Transformer 6

Transformator de msur de curent 123 kV 8


123 kV Current Transformer 8

Separatoare 123 kV 10
123 kV Disconnectors 10

Soluii complete de modernizare - Separatoare 123 kV 16


Complete solutions for 123 kV - Disconnectors refurbishing 16

Descrctoare cu ZnO pentru staii 110-400 kV 18


ZnO Surge Arresters for 110-400 kV Sustations 18

Descrctoare cu ZnO pentru LEA 110-400 kV 19


ZnO Surge Arresters for 110-400 kV Overhead Transmision Line 19

Izolatoare i lanuri de izolatoare compozite 110-400 kV 20


110-400 kV Insulators and Strings with Composite Insulators 20

Izolatoare suport compozite 110 kV 22


110 kV Station Post Insulators 22

Distanoare interfaz 110 kV 24


110 kV Interphase Spacers 24

Soluii moderne de consolidare a structurilor de beton din staii i linii electrice


folosind beton textil 26
Modern solutions to strengthen concrete structures of electric stations and
power lines using concrete textile 26

1 Eximprod Power Systems 2016


INTRODUCERE

La sfritul anilor '90, Eximprod livra primul su izolator compozit de 110 kV, la vremea aceea un
produs de import. Astfel marcam intrarea noastr pe o nou pia, cea de nalt tensiune. La
scurt timp de la acest eveniment, Eximprod a devenit primul productor de izolatoare compozite
din Romnia, pentru tensiuni ce urc pn la 400 kV.

Astzi avem o experien de 18 ani n producerea de echipamente i materiale, ca i n


implementarea unor complexe proiecte la cheie, astfel nct gama noastr de produse i servicii
pentru domeniul de tensiuni 110-400 kV include:
Izolatoare i lanuri de izolatoare compozite 110-400 kV
Izolatoare suport compozite 110 kV
Distanoare interfaz 110 kV
Separatoare 123 kV
Transformatoare de msur, de curent i tensiune
ntreruptoare
Proiectare i execuie la cheie linii electrice i staii 110-400 kV
Soluii la cheie pentru reconductorri LEA 110-400 kV
Sisteme SCADA.

mpreun cu partenerii notri externi oferim i ehipamente conexe n domeniul 110-400 kV,
astfel nct suntem astzi un furnizor complet:
Descrctoare pentru aplicaii de staie i linie
Transformatoare de putere etc.

Eximprod Power Systems 2016 2


INTRODUCTION

At the end of the '90s, Eximprod delivered the rst 110 kV composite insulator, at that time an
imported product. Thus, we started our high voltage business. Shortly after this, Eximprod
became the rst Romanian manufacturer of composite insulators for voltages up to 400 kV.

Today we have 18 years experience in high voltage sector, as a producer of materials and
equipment, as well as complex turn-key contractor so that our range of products and services
includes the following:
110-400 kV insulators and strings with composite insulators
110 kV station post insulators
110 kV Interphase spacers
123 kV Disconnectors
Instrument transformers
Circuit breakers
Designing and turn-key contracting of OHL and substations 110-400 kV
Turn-key reconductoring solutions for 110-400 kV OHLs
SCADA systems.

Together with our well-known global partners, we offer also other high equipment so that we are
today an one-stop supplier:
Station and line arresters
Power transformers etc.

3 Eximprod Power Systems 2016


ntreruptor tripolar 123 kV, 2500 A in SF6
123 kV SF6 Circuit Breaker

Echipamentul este complet testat in laboratoare acreditate la nivel european (CEI 62271-
100/2012, CEI 62271-1/2011).

This equipment is type tested by an European Accredited laboratory to strictly full or exceed the
latest EN/IEC norms. (IEC 62271-100/2012, IEC 62271-1/2011)

Nr. Caracteris ci tehnice U.M. Valoare


Item Technical characteris cs M.U. Value
1 Tensiune nominal / Rated Voltage kV 123
2 Frecvena nominal / Rated Frequency Hz 50
3 Curent nominal / Rated Current A 2500/3150*
4 Curent de rupere la scurt circuit Isc / Short circuit breaking current kA 40
Valoarea curentului de nchidere la scurt circuit (vrf) / Short circuit closing
5 kA 100
current (peak)
9 Durata nominal a scurt circuitului / Rated dura on of the short circuit s 3
10 Factorul primului pol / First pole factor 1,5
ntre contactele deschise ale ntreruptorului /
Tensiune de inere la 265
between open contacts
frecven industrial (1min.) /
11 kV
Insula on withstand voltage at fa de pmnt/ntre faze/ntre contactele
power frequency (1 min.) deschise / to earth/between phases/between 230
open contacts
ntre contactele deschise ale ntreruptorului /
Tensiune de inere nominal 630
between open contacts
la impuls de trsnet (vrf) /
12 fa de pmnt/ntre faze/ntre contacte / to kV
Insula on withstand voltage at
earth/ between phases/ between open 550
1,2/50s
contacts
13 Curent de rupere la poziie de faz / Out of phase breaking current kA 10
14 Curent de rupere linii n gol / Rated line charging breaking current A 31,5
15 Curent de rupere cabluri n gol / Rated cable charging breaking current A 140
compozit/porelan* /
16 Izolaie / Insula on type composite /
porcelain*
17 Secvena nominal de operare/ Rated opera on sequence D0,3sID180sID
18 Clasa / Class E2, M2, S2, C2
19 Presiunea nominal a gazului SF6 (20C) / Rated pressure of SF6 gas (20C) MPa 0,60
20 Presiunea minim a gazului SF6 (20C) / Minimum pressure of SF6 gas (20C) MPa 0,50
21 Presiune de alarmare/blocare a gazului SF6(20C) /
MPa < 0,55 / < 0,50
Signalizing / blocking level of SF6 gas (20C)
22 Scurgeri de gaz SF6 (an) / SF6 losses (year) % < 0,1

Eximprod Power Systems 2016 4


ntreruptor tripolar 123 kV, 2500 A in SF6
123 kV SF6 Circuit Breaker

5 Eximprod Power Systems 2016


Transformator de msur de tensiune 123 kV
123 kV Voltage Transformer

Echipamentul este complet testat in laboratoare acreditate la nivel european conform EN 61869-2.

This equipment is type tested by an European Accredited laboratory to strictly full or exceed the
latest EN/IEC norms. (EN 61869-2)

Transformatoare monofazate de tensiune


Caracteris ci tehnice/
de exterior, p TCI /
Technical characteris cs
Voltage transformers for outdoor use, type TCI
Tip transformator / Transformer type TCI 123 kV
Tensiunea maxim de ncercare a izolaiei, kV /
123 / 230 / 550
Maximum dielectric withstand, kV
Tensiune primar, V / Primary voltage, V 110000/3 15 %
Tensiune secundar msur , V / Secondary voltage, V 100 /3; 100; 110 /3; 110
Frecvena, Hz / Frequency, Hz 50
Clasa de precizie / Msur / measurement 0,2; 0,5; 1
Accuracy class Protecie / protec on 3P; 6P
Cl. 0,2 10; 25; 50; 60; 100
Puterea de precizie, VA / Msur / measure Cl. 0.5 10; 25; 30; 50; 60; 100;200; 500; 800
Secondary power, VA Cl. 1 10; 25; 30; 50; 60; 100;200; 500; 800
Protecie / protec on Cl. 3P,6P 10; 25; 30; 50; 60; 100;200; 500; 800
Tensiune secundar,
pentru clasa 3P sau 6P, V / 100 /3; 100; 110 /3; 110
Secondary voltage for class 3P and 6P, V
Puterea max. termic, VA / Total simultaneous burden, VA 1500
0 0
Temperatura mediu ambiant / Environmental temperature 40 C... + 50 C
Al tudinea maxim, m / Maximum al tude, m 2000

Eximprod Power Systems 2016 6


Transformator de msur de curent 123 kV
123 kV Current Transformer

Echipamentul este complet testat in laboratoare acreditate la nivel european conform EN 61869-5.

This equipment is type tested by an European Accredited laboratory to strictly full or exceed the
latest EN/IEC norms. (EN 61869-5)

Caracteris ci tehnice/ Transformator de curent pentru msurare TMCC/


Technical characteris cs Current transformer for measurement TMCC
Tip Transformator / Type of transformer TMCC 110
Tensiunea maxim de ncercare a izolaiei, kV / 123/ 230 /550
Maximum dielectric withstand, kV
Curent primar, A / Primary current, A Intre/Between 50 A si/and 2000A
Numrul de trepte comutabile n primar / 2x
Number of current switching steps in primary side Minimum 2x50 A; Maximum 2x2000 A
Curent secundar (msura), A / Secondary current, A 1A; 2A; 5A;
Frecvena, Hz / Frequency, Hz 50
Clasa de exac tate / Accuracy class 0,2S,02,0,5S,0,5,1
0,2S 5;10;25;50;60;100
Clasa de exac tate
0,2 5;10;25;50;60;100
Putere, VA (msura) /
0,5S 5;10;25;30;50;60;100
Power, VA Accuracy class
0,5 5;10;25;30;50;60;100
(measure)
1 10;25;30;50;60;100;200;500;800
Curentul de scurt circuit termic / Short circuit current Ith=40 kA/1s
Curentul de scurt circuit dinamic / Idin=2,5x Ith
Short circuit current (peak value)

Eximprod Power Systems 2016 8


Separatoare 123 kV
123 kV Disconnectors

Separatoarele de 123 kV fabricate de ctre EXIMPROD reprezint o soluie economic,


adaptat att pentru nlocuirea celor existente, ct i pentru staiile noi.

The 123 kV disconnectors manufactured by EXIMPROD represents a competitive solution both


for replacing of the old ones as well as for new substations.

Tipuri separatoare
Cu dou / cu un / fr cuite de legare la pmnt
Tripolare / Monopolare
Montaj n paralel / n linie

Designs
With two / with one / who earthing blades
Three-phase / one phase
phases mounted in line / in parallel

Testat complet electric i mecanic la ICMET Craiova, laborator acreditat


Full electrical / mechanical tests in ICMET Craiova, accredited laboratory

ncercri de tip / Type tests


ncercri dielectrice / Dielectric Test
ncercri pentru tensiunea de perturbaii radio-
electrice / Radio Interference Voltage (RIV) Tests
Msurarea rezisentelor ohmice ale circuitului
principal / Measurement of the Resistance of the main
circuit
ncercri de nclzire / Temperature-rise Tests
ncercri la curent de scurt durat admisibil i la
valoarea de vrf a curentului admisibil / Short-time
withstand current and peak withstand current Tests
ncercri de verificare a gradului de protecie /
Verification of the protection Tests
ncercri mecanice / Operating and mechanical
endurance Tests
ncercri pentru verificarea funcionrii n condiii
severe de formare a gheii / Operation under sever ice
conditions Tests
ncercri (calcule) la seism / Breviary for calculating
the earthquake simulation

Eximprod Power Systems 2016 10


Separatoare 123 kV
123 kV Disconnectors

Separator 123 kV - montaj n paralel


123 kV Disconnector - design in parallel

Eximprod Power Systems 2016 12


Separatoare 123 kV
123 kV Disconnectors

Caracteristici tehnice Separatoare 123kV Eximprod


Technical Characteristics of the Eximprods 123 kV
Disconnectors

Tensiune nominal / Rated Voltage 123 kV


Curent nominal / Rated Current 1600 A
Curentul nominal termic de scurt durat /
Rated thermal shortcircuit current 40 kA
Curentul nominal dinamic /
Rated dynamic shortcircuit current 100 kA
Durat scurtcircuit / Shortcircuit duration 3s
Tensiunea nominal de inere la frecven industrial / 50Hz, 1 min.
Insulation withstand voltages at power frequency
Fa de pmnt / To earth 230 kV
ntre contactele deschise / Between open contacts 265 kV
Tensiunea de inere la impuls de trznet / 1,2/50s
Insulation withstand voltages at impulse
Fa de pmnt / to earth 550 kV
ntre contactele deschise / between open contacts 630 kV
(continuare pe verso / continued on back)

13 Eximprod Power Systems 2016


Separatoare 123 kV
123 kV Disconnectors

Caracteristici tehnice
Technical Characteristics

Grosimea maxim a stratului de Ghea / 24 mm


Maximum ice tickness
Grad de protecie dispozitiv acionare / IP54
Protection degree of the operating mechanisms box
Tensiune nominal alimentare motor dispozitiv acionare/ 220 V c.a., 400 V c.a.
Rated input voltage of the operating mechanism
Tensiunea nominal de comand dispozitiv acionare / 110 V c.a., 110 V c.c., 220 V c.a., 220 V c.c.
Rated command voltage of the operting mechanism
Dimensiune ntre axele izolatorilor aceluiai pol / 1400 mm
Dimension between the insulators axes of the same pole

Eximprod Power Systems 2016 14


Separatoare 123 kV
123 kV Disconnectors

Separator 123 kV montaj n linie


123 kV Disconnector design in line

15 Eximprod Power Systems 2016


Soluii complete de modernizare - Separatoare 123 kV
Complete Solutions for 123 kV - Disconnectors Refurbishing

Soluii complete de modernizare separatoare 123 kV:


nlocuire separator i dispozitive acionare separator cu pstrarea suportului existent;
nlocuirea cuitelor principale, a izolatoarelor i a dispozitivelor de acionare cu pstrarea
suportului i a cinematicii existente;
nlocuirea cuitelor principale i a izolatoarelor existente cu pstrarea suportului, a
dispozitivelor de acionare i a cinematicii existente.

Eximprod Power Systems 2016 16


Soluii complete de modernizare - Separatoare 123 kV
Complete Solutions for 123 kV - Disconnectors Refurbishing

Complete solutions for 123 kV Disconnectors


refurbishing:
Replacement of the disconnector and of the operating
mechanism and maintening the existing support;
Replacement of the main blades, the insulators and
the operating mechanisms and maintening the
existing support and the existing kinematic
Replacement of the main blades and the insulators
and maintening the existing support, operating
mechanism and the kinematic.

17 Eximprod Power Systems 2016


Descrctoare cu ZnO pentru staii 110-400 kV
ZnO Surge Arresters for 110-400 kV Sustations

Poz. Caracteristici tehnice U.M. Valoare


Item Technical characteristics M.U. Value
PVI VH3 VH3
1. Tensiunea cea mai ridicat a reelei kV 123 245 420
Maximum system voltage
2. Tensiunea de funcionare continu kV 76 153,50 268,80
Maximum continous operating voltage
3. Tensiunea nominal kV 96 192 336
Rated voltage
4. Stabilitatea la supratensiuni temporare
Temporary overvoltage stabilility kV 111 235 385
la 1 secund / at 1 second kV 106 220 365
la 10 secunde / at 10 seconds
5. Curentul nominal de descrcare, unda 8/20 s kAmax 10 10 10
Rated discharge current, wave 8/20 s
6. Curentul de mare amplitudine, unda 4/10 s kAmax 100 100 100
Permissible impulse current, wave 4/10 s
7. Curentul rectangular, unda 2000 s Amax 500 500 500
Permissible impulse current, wave 2000 s
8. Clasa de descrcare a liniei 2 3 3
Line discharge class
9. Clasa limitatorului de presiune kA 60 65 65
Pressure relief class
10. Tensiunea rezidual la 10kAmax 8/20 s kVmax 234 454 795
Discharge voltage at 10kAmax 8/20 s
11. Tensiunea rezidual la impuls de comutaie la 500 Amax:
kVmax 183,20 430 650
Discharge voltage at switching surge impulse at 500 Amax
12. Nivelul descrcrilor pariale la 1.05 Un pC max. 10 max. 10 max. 10
Partial discharge level at 1.05 Ur
Not / Note:
Caracteristici tehnice i ncercri conform standardului IEC 99-4 / Technical data and testing per IEC 99-4
Set de 3 izolatoare suport baz i un contor nregistrare descrcri, cu miliampermetru ncorporat, incluse n furnitura
fiecrui descrctor / 3 pcs. Subbases insulators and 1 pc. surge counter with a build-in miliammeter are included for
each arrester.

Eximprod Power Systems 2016 18


Descrctoare cu ZnO pentru LEA 110-400 kV
ZnO Surge Arresters for 110-400 kV
Overhead Transmision Line

Poz. Caracteristici tehnice U.M Valoare


Item Technical characteristics M.U. Value
1. Tensiunea cea mai ridicat a reelei
kV 123 245 420
Maximum system voltage
2. Tensiunea de func ionare continu (Uc)
Continous operating voltage (Uc) kV 84 180 255
3. Tensiunea nominal (UR )
kV 108 228 318
Rated voltage (U R)
4. Stabilitatea la supratensiuni temporare
Temporary overvoltage stabilility
114,48 kV/Ur
la 1 secund / at 1 second kV 262 357
108 kV/Ur
la 10 secunde / at 10 seconds kV 251 336
5. Curentul nominal de descrcare, unda 8/20 s
kAmax 10 10 10
Rated discharge current, wave 8/20 s
6. Tensiunea rezidual al impuls de comutaie: Amax.
Residual voltage at switching impulse:
la 500Amax (unda 30/60 s) / at 500 A max. (30/60 s wave) 211 435 676
la 1000 Amax (unda 30/60 s) / at 1000 A max. (3 0/60 s wave ) 453 710

la 2000 Amax (unda 30/60 s) / at 2000 A max. (30/60 s wave ) 744

la 5000 Amax (unda 30/60 s) / at 5000 A max. (8/20 s wave) 249 511 778

la 10000 Amax (unda 30/60 s) / at 10000 A max. (8/20 s wave) 268 548 838

la 20000 Amax. (unda 30/60 s) / at 10000 A max. (8/20 s wave) 298 593 914

7. Curentul de mare amplitudine, unda 4/10 s


kAmax 100 100 100
Permissible impulse current, wave 4/10 s
8. Tensiunea de inere la impuls tip trsnet (unda (1,2/50 s) / Withstand
kV max
voltage at lighting impulse of the housing (1,2/50 s wave) 742 1166 2100

9. Tensiunea de inere la impuls de frecven industrial 50 Hz, 1 minut, 800 kV


312 kV rms la
sub ploaie / Withstand voltage at industrial frequency, 50 Hz, 1 kVef 977 rms la
60 Hz
minute, wet conditions 60 Hz
Not / Note:
Caracteristici tehnice i ncercri conform standardului IEC 99-4 / Technical data and testing per IEC 99-4

19 Eximprod Power Systems 2016


Izolatoare i lanuri de izolatoare compozite 110-400 kV
110-400 kV Insulators and Strings with Composite Insulators

Izolatoare compozite pentru LEA i staii 110-400 kV


Composite Insulator for 110-400kV Overhead Lines
and Substations

Poz. Caracteristici tehnice U.M Valoare


Item Technical characteristics M.U. Value
1. Tensiunea maxim a reelei
kV 123 245 420
Maximum system voltage
2. Tensiunea nominal
kV 110 220 400
Rated voltage
3. Tensiunea de inere la impuls tip
trsnet (unda 1,2/50 s)
kVmin 550 1050 1550
Dry lighting impulse voltage
withstand (1,2/50 s wave)
4. Tensiunea de inere la frecven
industrial sub ploaie (50 Hz, 1 min)
Wet power frequency withstand kVef 230 460 680
voltage (50 Hz, 1 min.)
5. Tensiunea disruptiv 50% la impuls de
tensiune tip trsnet (unda 1,2/50 s)
kVmax 690 1310 1930
50% dry lighting impulse voltage
(1,2/50 s wave)
6. Tensiunea de inere la impuls de
comutaie sub ploaie
(unda 250/2500 s) kVmax 440 750 1050
Wet switching impulse withstand
voltage (wave 250/2500 s)
7. Curent de scurt circuit timp de o secund kA 31,5 31,5/40 40
Short circuit current (1 sec.)
8. Nivelul RIV
V 2500 2500 2500
RIV level
9. Sarcina mecanic specificat (SMS)
kN 120 160 120 160 120 160
Specified mechanical load (SML)
10. Lungime de montaj
mm 1240 1270 1240 1332 2276 2432 2588 2497 2497 2653 3673 3517 3747 3895 3895 3813
Mounting length
11. Linia de fug specific mm/
20,24 20,14 31,14 31,11 20,57 25,59 31,22 22,04 26,22 31,22 20,33 25,50 31,45 21,12 25,35 31,45
Specified creepage distance kV
12. Mod de cuplare
(CEI 120) 16 20 16 20 16 20
Coupling (CEI 120)
Not / Note:
Caracteristici tehnice i ncercri conform standardului CEI 1109 / Technical characteristics and testing per CEI 1109
Valorile caracteristicilor electrice corespund echiprii izolatoarelor cu armturi de protecie / Electrical characteristics
available for insulators equiped with arcing horns

Eximprod Power Systems 2016 20


Izolatoare i lanuri de izolatoare compozite 110-400 kV
110-400 kV Insulators and Strings with Composite Insulators

Lanuri echipate cu izolatoare compozite


pentru LEA i staii 110-400 kV
Strings Equiped with Composite Insulator for 110-400kV
Overhead Lines and Substations
Poz. Simbol / Symbol
Tip lan / Type
Item 110 kV 220 kV 400 kV
1 Lanuri LEA / strings for overhead lines
Lan simplu de susinere LSS110120II(III,IV) LSS220120(160) LSS400120(160)
1.1
Single suspension string 185/32(240/40) II(III,IV) (300/50)450/75 II(III,IV)2x450/75
Lan dublu de susinere LDS110120II(III,IV) LDS220120(160) LDS400120(160)
1.2
Double suspension string 185/32(240/40) II(III,IV) (300/50)450/75 II(III,IV)2x450/75
Lan simplu de ntindere LSI110120(160)II(III,IV) LSI220120(160)
1.3
Single tension string 185/32(240/40) II(III,IV) (300/50)450/75
Lan dublu de ntindere LDS110120(160)II(III,IV) LDI220120(160) LDI400160II(III,IV)
1.4
Double tension string 185/32(240/40) II(III,IV) (300/50)450/75 2x450/75
Lan triplu de ntindere LTI400160II(III,IV)
1.5
Triple tension string 2x450/75
2 Lanuri staii / strings for substations
Lan simplu de susinere LSSs110120(160)II(III,IV) LSSs220120(160) LSSs400120(160)
2.1
Single suspension string (300/50)450/75 II(III,IV)(2x)450/75 II(III,IV)2x450/75
Lan dublu de susinere LDSV110120(160)II(III,IV) LDSV220120(160) LDSV400120(160)
2.2
Double suspension string (2x)(300/50)450/75 II(III,IV)(2x)450/75 II(III,IV)2x450/75
Lan dublu de ntindere n V LIVs110120(160)II(III,IV) LIVs220120(160) LIVs400160II(III,IV)
2.3
V type double tension string (2x)450/75 II(III,IV)(2x)450/75 2x450/75
Exemplu echipare lan dublu de ntindere 110 kV / Example of double tension string 110 kV:
- Crlig traciune tip B / Swivel type B = 1 buc.;
- Ochi dublu rsucit OD 20 / Double twisted eye OD 20 = 2 buc.;
- Jug simplu Js 300/16 / Single yoke Js 300/16 = 2 buc.;
- Izolator compozit 110 kV/ Composite insulator 110 kV = 2 buc.;
- Corn descrcare CP110/ Arcing horn CP110 = 4 buc.;
- Ochi de susinere OTp / Suspension eye OTp = 4 buc.;
- Clema de traciune TPDF(c) / Compression clamp TPDF(c) = 1 buc.;

Not / Note:
La cerere, asigurm toate tipurile i configuraiile de lanuri destinate LEA i staiilor 110-400 kV
Full equiped strings for 110-400 Overhead Lines and Substations, per your request.

21 Eximprod Power Systems 2016


Izolatoare compozite suport 110 kV
110-400 kV Station Post Insulators

Izolatoare compozite suport pentru separatoare 110 kV i


susinerea barelor
Composite Post Insulators for 110 kV Disconnectors and
Busbar Support

Valoarea
Caracteristica U.M. Value
Technical data U.M.
ICS 110-550 ICS 110-650
Tensiunea nominal a reelei
kV 110 110
Nominal system voltage
Linia de fug minim
mm 3820 5000
Minimum creepage distance
Tensiunea de inere la impuls de trsnet
(1,2/50 s) kV 550 650
Dry lightning impulse voltage (1,2/50 s)
Tensiunea de inere la frecven industrial
sub ploaie (1 min) kV 230 275
Wet powerfrequency withstand (1 min.)
Sarcina de traciune specificat (STL)
kN 100 100
Specified tensile load (STL)
Sarcina de ncovoiere specificat (SCL)
kN 10 10
Specified cantilever load (SCL)
Momentul de torsiune specificat (SToL)
kNm 4 4
Specified torsion load (SToL)
Lungime (L)
mm 1210 1515
Length (L)
Durata de via ani
40 40
Life span years

SIMBOLIZARE / SYMBOL: ICS 110 550 (650)

Izolator Compozit Suport


ICS
composite post insulator
tensiunea nominal a reelei (kV)
110
nominal system voltage (kV)
550 tensiunea de inere la impuls de trsnet (kV)
(650) dry lightning impulse voltage (kV)

Eximprod Power Systems 2016 22


Izolatoare compozite suport 110 kV
110-400 kV Station Post Insulators
Izolatoare compozite suport
pentru susinerea barelor plate n staii
Station Post Insulators for Flat Busbars
Valoarea
Caracteristica U.M. Value
Technical data U.M.
ICS-24A/SB ICS-CF/SB
Tensiunea maxim de serviciu a reelei
kV 24 33
Maximum system voltage
Linia de fug
mm 605 1207
Creepage distance
mm x mm 20x100 20x100
Crosssection of the busbar
Tensiunea de inere la impuls de trsnet (1,2/50 s)
kV 125 250
Dry lighting impulse voltage (1,2/50 s)
kV 50 125
Wet powerfrequency withstand (1 min.)
kN 40 100
Specified tensile load (STL)

kN 4 6

Sarcina maxim de ncovoiere n exploatare (MDCL)


kN 2 5
Maximum design cantilever load (MDCL)
Masa
kg 2,77 5.00
Weight
Durata de via ani
40 40
Life span years

SIMBOLIZARE / SYMBOL: ICS 24A / SB SIMBOLIZARE / SYMBOL: ICS CF / SB

ICS- Izolator Compozit Suport ICS - Izolator Compozit Suport


composite line post insulator composite line post insulator
24 - tensiunea maxim a reelei (kV) SB - destinat Susinerii Barelor plate n staii
maximum system voltage (kV) for busbars
A - pentru Aparate
for apparatus
SB - destinat Susinerii Barelor plate n staii
for busbars

Nota / Note:
n comand se va specifica grosimea efectiv a barei plate, intensitatea curentului care circul prin bara plat i materialul barei
plate. / Effective witdth of busbar, rated current in the busbar and the material of busbar will be mentioned in your order.

23 Eximprod Power Systems 2016


Distanoare interfaz 110 kV
110-400 kV Interphase Spacer

Distanor interfaz
pentru liniile electrice aeriene de 110 kv
Interphase Spacer for 110 kv Overhead Line

SIMBOLIZARE / SYMBOL
DI - 110 / d
DI - distanor interfaz / interphase spacer
110 kV- tensiunea nominal a reelei / rated voltage
d distana dintre conductoarele liniei electrice (mm) / distance
between OHL conductors (mm)

Poz. /
Componen / Componence Buc. / Pcs.
Pos.
1 Izolator 1 / Insulator 1 1
2 Distanier / Spacer 1
3 Izolator 2 / Insulator 2 1
4 Ochi cu prindere pe ptrat OT p / Suspension eye type OTp 2
5 Clem / Clamp 2
Band aluminiu (se nfoar pe conductor la montaj) /
6 1
Aluminium band (enfold around the conductor in situ)

Nr. crt. / Valori /


Caracteristici / Characteristics UM
Pos. Values
1 Tensiunea nominal / Rated Voltage kV 110
2 Tensiunea maxim a reelei / Maximum system voltage kV 123
Tensiunea nominal de inere la impuls de tensiune de trsnet (1,2/50
3
s) / Dry lightning impulse withstand voltage (1,2 / 50s ) kVmax 550
Tensiunea nominal de inere 1 minut la tensiune de frecvena
4
industrial sub ploaie / Wet powerfrequency withstand voltage (1 min.) kVef 230
5 Linia de fug a izolatorului / Creepage distance mm 2477
6 Linia de fug total / Total creepage distance mm 4954
7 Sarcina de rupere la traciune / Tensile load kN 50
min. 3000
8 Distana dintre conductoare / Distance between conductors mm
max. 7000
9 Durata de via normat / Life span ani/years min. 40

Eximprod Power Systems 2016 24


Soluii moderne de consolidare a structurilor de beton
din staii i linii electrice folosind beton textil

Prezenta tehnologie s-a dezvoltat n urma derulrii unui contract de cercetare ncheiat cu
TUDAG/Deutschen Zentrum Textilbeton (German Centre for Textile Reinforced Concrete),
reprezentat de Dl. Ammar Al-Jamous (Dipl.-Ing.), CEO of the German Centre for Textile
Reinforced, Universitatea de Construcii din DRESDA, Germania, care deine brevetul cu
nr. 302008014750.4, nregistrat la Registrul German pentru Brevete i Mrci.

Tehnologia propus reprezint o alternativ la nlocuirea cu structuri din metal a structurilor


din beton armat montate n reelele electrice.

This technology was developed after the completion of a


research contract with TUDAG / Deutschen Zentrum
Textilbeton (German Centre for Textile Reinforced
Concrete), represented by Mr. Ammar Al-Jamous (Dipl.-
Ing.), CEO of the German Centre for Textile Reinforced
University Building in Dresden, Germany, which holds
the patent no. 302008014750.4, registered at the
German Patent and Trade Mark Registry.

The proposed technology is an alternative to replacing


the metal structures of reinforced concrete structures
installed in electric networks.

Eximprod Power Systems 2016 26


Modern solutions to strengthen concrete structures of
electric stations and power lines using concrete textile

Avantaje:
valorile parametrilor mecanici ai structurilor din beton armat reparate/ntrite,
aplicnd tehnologia cu beton textil, depesc cu peste 40% parametrii mecanici
iniiali ai structurilor existente;
o economie semnicativ de timp i costuri comparativ cu soluia clasic de ntrire a
structurilor din beton existente cu structuri metalice i fundaie din beton;
evitarea utilizrii componentelor din oel la exterior i, n consecin, riscuri minime de
apariie a coroziunii i cheltuieli reduse de mentenan;
durat redus de indisponibilitate a echipamentelor (o parte din lucrri se pot executa cu
instalaiile n funciune cu respectarea distanei de apropiere fa de prile din instalaii
aate sub tensiune);
implementarea tehnologiei nu presupune obinerea de avize i acorduri;
durata de via a structurilor dup reparaii se prelungete cu 30 de ani n
condiiile exploatrii normale cu solicitri n limita valorilor avute n calcul la
proiectarea unei linii noi.

Advantages:
values of mechanical parameters
of reinforced concrete structures
repair / strengthened by applying
concrete textile technology,
exceeding by 40% the original
mechanical parameters of
existing structures;
signicant savings of time and
cost than the alternative of
strengthening existing concrete
structures with steel structures
and concrete foundation;
avoiding the use of steel
components on the outside and
therefore minimal risk of
corrosion and low maintenance
costs;
shortened unavailability of
equipment (some of the works
can be carried out with respect
plant running distance closer to
the energized parts of plants);
technology implementation does
not involve obtaining approvals
and agreements;
life of structures repaired lasts 30
years under normal operation
with requests for the amounts
taken into account in the design of
a new line.

27 Eximprod Power Systems 2016


Sediul Central / Headquarters Office Germania / German Office
Str. Bistriei, nr. 3, Buzu, Romnia, 120038 Sdliche Mnchner Str. 15 D82031 Grnwald, Germany
Tel.: +40 238 710 242 Fax: +40 238 710 384 Phone: +49(0)8969758613
Email: office@eximprod.ro Email: info@epsenergie.de
Web: www.eximprod.ro Web: www.epsenergie.de

Reeaua Comercial Naional / National Commercial Network:


BUCURETI, Splaiul Unirii, nr. 313, Tel/Fax: 021. 346. 46. 92

CLUJ - NAPOCA, Str. Teleorman, nr. 68, Tel/Fax: 0264. 430. 456

BACU, Str. Republicii, nr. 166, Tel/Fax: 0234. 588. 890

BRAOV, Str. 13 Decembrie, nr. 17A, Tel: 0268. 413. 967

TIMIOARA, Str. Martir Ion Miron (fost Scrioara), nr. 30, Tel/Fax: 0256. 212. 135

TG. MURE Distribuitor: SC ENERGO GTI SRL, Tel: 0720. 531. 537, Fax: 0265. 219. 145

IAI, Bd. Tudor Vladimirescu, nr. 4244, et. 3, cod potal 700305, Tel: 0730.650.406, Fax: 0332.816.832

Copyright 2016 Eximprod Power Systems SRL. 2EPS\VNZ\INT\00040.

Toate drepturile rezervate. Este interzis copierea, fotocopierea, reproducerea sau traducerea, prin orice mijloc, n ntregime sau n parte, a oricrei pri din acest catalog, inclusiv grafice,
tabele sau desene, fr permisiunea prealabil scris a Eximprod Power Systems SRL
All rights reserved. No part of this catalogue including graphics, tables or designs may be copied, photocopied, reproduced or translated, by any means, in whole or in part, without prior
written consent of Eximprod Power Systems SRL

S-ar putea să vă placă și