Documente Academic
Documente Profesional
Documente Cultură
1. Predimensionarea sectiunii
2
Forta axiala normalizata- ν d=NEd/(b ·f cd)<0.25= 0.0307
Ned (kN)=A· q= 590.976
Sectiune propusa stalp b(mm)= 850
2
Aria aferenta stalp A(m )=t·L=288
Travee hala t(m)= 12.00
Deschidere hala L(m)= 24.00
2
Incarcare la niv. acop. q (kN/m )= 2.052
f cd (N/mm2)= 26.67
2
f ck (N/mm )= 40 C 40/50
γc= 1.5
val. in comb.
val. caract. coef. incarc.
Evaluare Incarcari la nivelul acoperisului seismica
(kN/m )
2 Ψ2,i 2
(kN/m )
a) Grinzi principale (precomprimate) 0.800 1.00 0.8
b) Pane (precomprimate) 0.000 1.00 0
c) Pane (metalice) 0.000 1.00 0
d) Contravantuiri 0.050 1.00 0.05
e) Spatiu tehnic 0.250 1.00 0.25
f) Hidroizolatie cu membrana 0.050 1.00 0.05
g) Termoizolatie (20cm) 0.240 1.00 0.24
i) Tabla cutata 0.150 1.00 0.15
j) Zapada 1.280 0.40 0.512