Sunteți pe pagina 1din 12

Predimensionare

Medb+ = 152 KNm camp


Medb- = 192 KNm reazem
c=acoperirea minima cu beton 3 cm
d1=d2=c+/2 acoperire cu beton 4 cm
As nec=M camp/(h-d1-d2)*fyd
armatura d.bl 2 cm
poptim 1 %
bw 35 cm
r 2.8053375
h0nec 44.298638 cm
hgp nec 48.298638 cm
hgpfinal 85 cm
h0 81 cm
B=Mrmax/(bw*h0^2*fctk) 0.3800498
= 0.1363636
L= 11.7
h= 850
bw= 350
g= KN-incarcare permanenta
q= kn-incarcare variabila uniform distribuita
Caracteristicile materialelor
fyk= 345 N/mm^2
s=
1.15
fyd=fyd/s
300 N/mm^2
s= 1.5
Beton clasa : C35/45
fck= 35 N/mm^2
fctm= 3.2 N/mm^2
fctk= 2.2 N/mm^2
fcd=fck/s 23.3 N/mm^2
fcd=fctk/s 1.5 N/mm^2
Calcul unei grinzi de cadru in clasa de ductilitate medie
1.Date de intrare
Date geometrice si incarcari
m-deschiderea interax
mm-inaltimea sectiunii transversale a grinzii
mm-latimea grinzii
Armatura longitudinala-Otel BST 500S,Clasa C:
coeficient partial de siguranta
Armatura transversala-Otel BST 500S,Clasa C:
coeficient partial de siguranta
Medb+ = 152 KNm
Medb- = 192 KNm Moment max negativ pe reazem
V= 153 KN Forta taietoare
Clasa structurala S3-(SR EN 1992-1-1:2004,TABEL 4.3N)
XC2
c min=max 25 mm
ctol 10 mm-pentru grinzi si stalpi
35
d1=d2=cnom+sl/2 47.5
50
d=h-d1 800
etr 10 mm
40 mm
20 <25mm deci acoperirea etrierilor este suficienta
Cantitatea minima de armatura la partea inferioara este data de:
min=0.5x(fctm/fyk) 0.0046377
Adica Asmin=*b*d 1298.5507 mm2
Alegem armatura 420 +416 cu aria de armatura
dbl 20 mm
A s= 1500 mm2
Se verifica ca aceasta armatura etse suficienta pentru preluarea momentului de calcul
Medb+ = 152 KNm
z=0.9d 720
MRD=As*fyd*z 324 KNm > 152 KNm
Se verifica
Medb- = 192 KNm
Se presupune ca
-853.33333 mm^2
Se aleg
420
As1= 1256 mm^2
Dimensionarea armaturii longitudinale la moment negativ
Se considera sectiunea dreptunghiulara dublu armata,cu armatura comprimata
rezultata la pasul precedent si momentul de calcul:
x<3*d2As1nec=Medb/(h-d1-d2)*fyd
Sectiunea de calcul este o sectiune T;se precizeaza bratul de parghie al
eforturilor interioare
Acoperirea cu beton a armaturilor
Clasa de expunere
ctol=c min+ctol mm-valoarea nominala a stratului de acoperire
distanta de la axul barei longitudinale pana la
partea superioara
mm-inaltimea utila a sectiunii grinzii
Acoperirea cu beton aarmaturii transversale(etrieri)
cef=cnom bl-etr
cnom etr=cmin etr+ctol
Dimensionarea armaturii longitudinale
Dimensionarea armaturii longitudinale la moment pozitiv
Moment max pozitiv in camp
Eforturi de proiectare
Determinarea fortei taietoare de proiectare
0.54
0.45
0= 0.4
0.5333333
337.5 KNm
282.6 KNm
337.5 KNm
282.6 KNm
In sectiunea de abscisa x,forta taietoare de calcul este:
= 206 KN
= 100 KN
0.4854369
VEd max 206 <(2+)*bw*dfctd)
= 1020.6861
= 0.4854369 > -0.5
VEd max 206 < (2+)*bw*dfctd)
Dimensionarea armaturii transversale in zonele critice
lcr 1.275 m
cw= 1
=VEd min/VEd max
Pentru elementele cu armaturi transversale de forta taietoare ,rezistenta la
fortataietoare VRd este cea mai mica dintre valorile de mai jos
VRd,s=(Asw/s)*fywd*ctg
VRd,max=(cw*bw*z*1*fcd/ctg+tg)
Pentru zonele critice de la capetele grinzilor (lcr=1.5h)se considera inclinarea
fisurilor fata de orizontala =45 iar bratul de parghie al fortelor interne Z=0.9d
pentru structuri fara precomprimare
VEd min=-(Mjd+Mjd)/l0+Ved
q'=(As1/d*bw)*100
%-procent de armare la partea
superioara a grinzii
Procentul minim de armare este:
pmin=(0.5*fctm/fck)=
%-mai mic decat procentele efective
Determinarea fortei taietoare de proiectare
MRB+=As*(h-d1-d2)*fyd
MRB-=As1*(h-d1-d2)*fyd
Mid=Mrbi*Rd*min(1,MRci/MRbi)
Mjd=Mrbj*Rd*min(1,MRcj/MRbj)
VEd max=(Mid+Mjd)/l0+Ved
Dimensionarea armaturii transversale
q=(As/d*bw)*100 %-procent de armare la partea
inferioara a grinzii
s= 120
Aleg s= 120 mm
1=0.6*(1-fck/250) 0.516
VRd,max 1517.04 > VEd max 206 KN
Asw= 114.44444 mm2
n=2Aw/2 0.5722222 mm2
Se aleg etrieri
qw,min=0.08*sqrt(fck)/fyk*100 Verificarea
qw,min= 0.1371845 %
qw,ef=(n*Aw/S*bw)*100
qw,ef= 0.0027249 %>qw,min
Verificarea cerintelor de ductilitate locala
Pentru a satisface conditia de ductilitate in regiunile critice ale grinzilor trebuie ca:
q0= 3.5 valoarea de baza a factorului de comportare
>=2*q0-1 6 pentru cladiri cu T1>=0.7 TC
Din conditii de ductilitate localas=min(h/4;150mm;6*dbl)
Asw=VRd,s*S/(z*fyd*d*ctg)
10/100mm
Beton clasa : C16/20 C20/25 C25/30
fck= 16 20 25 N/mm^2
fctm= 1.9 2.2 2.6 N/mm^2
fctk= 1.3 1.5 1.8 N/mm^2
mm-valoarea nominala a stratului de acoperire
Predimensionare
Medb+ = 152 KNm camp
Medb- = 192 KNm reazem
c=acoperirea minima cu beton 3 cm
d1=d2=c+/2 acoperire cu beton 4 cm
As nec=M camp/(h-d1-d2)*fyd
armatura d.bl 2 cm
poptim 1 %
bw 35 cm
r 2.5584086
h0nec 44.663242 cm
hgp nec 48.663242 cm
hgpfinal 85 cm
h0 81 cm
B=Mrmax/(bw*h0^2*fctk) 0.4645053
= 0.1666667
L= 11.7
h= 850
bw= 350
g= KN-incarcare permanenta
q= kn-incarcare variabila uniform distribuita
Caracteristicile materialelor
fyk= 345 N/mm^2
s=
1.15
fyd=fyd/s
300 N/mm^2
s= 1.5
Beton clasa : C25/30
fck= 25 N/mm^2
fctm= 2.6 N/mm^2
fctk= 1.8 N/mm^2
fcd=fck/s 16.7 N/mm^2
fcd=fctk/s 1.2 N/mm^2
coeficient partial de siguranta
coeficient partial de siguranta
Armatura longitudinala-Otel BST 500S,Clasa C:
Armatura transversala-Otel BST 500S,Clasa C:
Calcul unei grinzi de cadru in clasa de ductilitate medie
1.Date de intrare
Date geometrice si incarcari
m-deschiderea interax
mm-inaltimea sectiunii transversale a grinzii
mm-latimea grinzii
Medb+ = 152 KNm
Medb- = 192 KNm Moment max negativ pe reazem
V= 153 KN Forta taietoare
Clasa structurala S3-(SR EN 1992-1-1:2004,TABEL 4.3N)
XC2
c min=max 25 mm
ctol 10 mm-pentru grinzi si stalpi
35
d1=d2=cnom+sl/2 47.5
50
d=h-d1 800
etr 10 mm
40 mm
20 <25mm deci acoperirea etrierilor este suficienta
Cantitatea minima de armatura la partea inferioara este data de:
min=0.5x(fctm/fyk) 0.0037681
Adica Asmin=*b*d 1055.0725 mm2
Alegem armatura 420 +416 cu aria de armatura
dbl 20 mm
A s= 504 mm2
Se verifica ca aceasta armatura etse suficienta pentru preluarea momentului de calcul
Medb+ = 152 KNm
z=0.9d 720
MRD=As*fyd*z 108.864 KNm > 152 KNm
Se verifica
Medb- = 192 KNm
Se presupune ca
-853.33333 mm^2
Se aleg
420
As1= 2454 mm^2
x<3*d2As1nec=Medb/(h-d1-d2)*fyd
Dimensionarea armaturii longitudinale
Dimensionarea armaturii longitudinale la moment pozitiv
Sectiunea de calcul este o sectiune T;se precizeaza bratul de parghie al
eforturilor interioare
Dimensionarea armaturii longitudinale la moment negativ
Se considera sectiunea dreptunghiulara dublu armata,cu armatura comprimata
rezultata la pasul precedent si momentul de calcul:
distanta de la axul barei longitudinale pana la
partea superioara
mm-inaltimea utila a sectiunii grinzii
Acoperirea cu beton aarmaturii transversale(etrieri)
cef=cnom bl-etr
cnom etr=cmin etr+ctol
Acoperirea cu beton a armaturilor
Clasa de expunere
mm-valoarea nominala a stratului de acoperire ctol=c min+ctol
Eforturi de proiectare
Moment max pozitiv in camp
Determinarea fortei taietoare de proiectare
0.18
0.88
0= 0.4
0.4333333
113.4 KNm
552.15 KNm
113.4 KNm
552.15 KNm
In sectiunea de abscisa x,forta taietoare de calcul este:
= 209.88462 KN
= 96.115385 KN
0.4579439
VEd max 209.88462 <(2+)*bw*dfctd)
= 825.86916
= 0.4579439 > -0.5
VEd max 209.88462 < (2+)*bw*dfctd)
Dimensionarea armaturii transversale in zonele critice
lcr 1.275 m
cw= 1 pentru structuri fara precomprimare
VEd max=(Mid+Mjd)/l0+Ved
VEd min=-(Mjd+Mjd)/l0+Ved
=VEd min/VEd max
Pentru zonele critice de la capetele grinzilor (lcr=1.5h)se considera inclinarea
fisurilor fata de orizontala =45 iar bratul de parghie al fortelor interne Z=0.9d
Pentru elementele cu armaturi transversale de forta taietoare ,rezistenta la
fortataietoare VRd este cea mai mica dintre valorile de mai jos
VRd,s=(Asw/s)*fywd*ctg
pmin=(0.5*fctm/fck)=
%-mai mic decat procentele efective
VRd,max=(cw*bw*z*1*fcd/ctg+tg)
MRB+=As*(h-d1-d2)*fyd
MRB-=As1*(h-d1-d2)*fyd
Mid=Mrbi*Rd*min(1,MRci/MRbi)
Mjd=Mrbj*Rd*min(1,MRcj/MRbj)
Determinarea fortei taietoare de proiectare
Dimensionarea armaturii transversale
%-procent de armare la partea
inferioara a grinzii
q=(As/d*bw)*100
q'=(As1/d*bw)*100
%-procent de armare la partea
superioara a grinzii
Procentul minim de armare este:
s= 120
Aleg s= 100 mm
1=0.6*(1-fck/250) 0.54
VRd,max 1134 > VEd max 209.8846 KN
Asw= 116.60256 mm2
n=2Aw/2 0.5830128 mm2
Se aleg etrieri
qw,min=0.08*sqrt(fck)/fyk*100 Verificarea
qw,min= 0.115942 %
qw,ef=(n*Aw/S*bw)*100
qw,ef= 0.0027763 %>qw,min
Verificarea cerintelor de ductilitate locala
Pentru a satisface conditia de ductilitate in regiunile critice ale grinzilor trebuie ca:
q0= 3.5 valoarea de baza a factorului de comportare
>=2*q0-1 6 pentru cladiri cu T1>=0.7 TC
Din conditii de ductilitate localas=min(h/4;150mm;6*dbl)
Asw=VRd,s*S/(z*fyd*d*ctg)
10/100mm
Beton clasa : C16/20 C20/25 C25/30
fck= 16 20 25 N/mm^2
fctm= 1.9 2.2 2.6 N/mm^2
fctk= 1.3 1.5 1.8 N/mm^2
mm-valoarea nominala a stratului de acoperire