Chereji Razvan

Grupa: 32401
PROIECT CBA II n=9

S se dimensioneze elementele structurii din schiele de mai jos, avnd n


vedere urmtoarele date

a 5.25 m b 4.15 m c 5.65 m d 6.65 m

l1 a + 0.05 m n = 5.7 m l1 + l2 + l1 + l2 + l1 t2 + t1 + t2

l2 b + 0.1 m n = 5.05 m

t1 c - 0.05 m n = 5.2 m

t2 d - 0.1 m n = 5.75 m

qn ncrcarea util la nivele curente (n impar = birouri, n par = locuine)

nl 4 (nr de nivele)

h1util 3.5 m -inaltimea utila a parterului

h2util 2.8 m -inaltimea utila a celelalte nivele

Cldirea studiat se afl n localitatea Focsani, avnd structur n cadre


pe cele dou direcii ortogonale. Dimensiunile n plan ale cldirii:

l1 + l2 + l1 + l2 + l1 t2 + t1 + t2 nniv 4

ag 0.4 g Tc 1 s

n=9 -> faad ventilat, perei interiori de gipscarton, pardoseal tehnic

Created with PTC Mathcad Express. See www.mathcad.com for more information.
Vedere in plan:

Sectiune in plan:

2.Evaluarea Incarcarilor

Created with PTC Mathcad Express. See www.mathcad.com for more information.
2.Evaluarea Incarcarilor
2.1.Evaluarea incarcarilor gravitationale
2.1.1.Incarcarilor permanente

Created with PTC Mathcad Express. See www.mathcad.com for more information.
kN kN kN
gkper.E.T 3.23 2
2.80 m = 9.044 bet 25
m m m3
kN kN kN
gkper.E.L 3.23 2.95 m = 9.529 gplanseu 7.88
m2 m m2
kN kN kN
gkper.P.T 3.23 3.5 m = 11.305 gterasa 6.60
m2 m m2
kN kN kN
gkper.P.L 3.23 3.65 m = 11.79 gp.despartitori 0.375
m2 m m2
kN kN
gkAtic.P.T 4.65 0.6 m = 2.79
m2 m
2.1.2.Incarcarilor utile (CR 0-2012)
Cladire pentru birouri se incadreaza in categoria B,cu incarcari utile gu 2.5
kN
m2
2.1.2.Incarcarea din zapada pe acoperis

gis 1.10 Clasa II


ce 1.00 Tip expunere:Normala
i 0.8 Panta acoperis<30
kN
S0.k 2.00 2 kN
sk gis i cme S0.k = 1.76
m2

Predimensionarea elementelor structurale:

Created with PTC Mathcad Express. See www.mathcad.com for more information.
Predimensionarea elementelor structurale:
Predimensionarea grinda secundara:

-conditii tehnologice:la grinzile monolite dimensiunile sectiunii transversale din


considerente practice se stabilesc multiplu de 50 mm
- hs , bs -multiplu de 50 mm
-conditiie de geometrie (P100-1/2013):
-latimea grinzilor va fi cel putin 200 mm( bps 200 mm )
-raportul intre latimea ( bgs ) si inaltime ( hgs ) nu va fi mai mic decat 1/4
-conditiie de rigiditate:-inaltimea minima se determina in functie de deschiderea de
calcul hgs =( ... )l
1 1
10 15

aleg
l1
hgs = 57 cm hgs 60 cm
10
-este recomandat valorile raportul hgs / bgs =1.5...3
hgs
bgs = 30 cm
2
-conditiie de rezistenta la foc: bgs 200 mm (R120)

Aleg grinda secundara: 30x60 bgs = 30 cm hgs = 60 cm

Predimensionarea grinda principala:


-conditii tehnologice:la grinzile monolite dimensiunile sectiunii transversale din
considerente practice se stabilesc multiplu de 50 mm
- hgp , bgp -multiplu de 50 mm
-conditiie de geometrie (P100-1/2013):
-latimea grinzilor va fi cel putin 200 mm( bpg 200 mm )
-raportul intre latimea ( bgp ) si inaltime ( hgp ) nu va fi mai mic decat 1/4
-conditiie de rigiditate:-inaltimea minima se determina in functie de deschiderea de
calcul hgp =( ... )l
1 1
8 12

aleg
t2
hgp = 71.875 cm hgp 75 cm
8
-este recomandat valorile raportul hgp / bgp =1.5...3
hgp
bgp = 37.5 cm
2
-conditiie de rezistenta la foc: bgp 200 mm (R120)

Aleg grinda principala: 40x75 bgp 40 cm hgp = 75 cm

Created with PTC Mathcad Express. See www.mathcad.com for more information.
Predimensionarea placa:
-Conditii tehnologice:-grosimea placi din beton armat turnat monolit se ve stabili
astgel incat sa fie multiplu de 10 mm
-Conditii de rigiditate:-ochiurile de placa au descarcare bidirectionala
avand raportul laturilor lmax / lmin <2

hp = placa este incastrata elastic pe tot conturul


lmin
45

lmin -min( ln1 , ln2 )-din ochiul de placa cel mai mare

bgs
ln1 l1 - 2 = 5.4 m
2
bgp
ln2 t2 - 2 = 5.35 m
2
lmin min ln1 , ln2 = 5.35 m
lmin
hp = 11.889 cm
45
-Conditie de grosime minima:-grosimea minima a unei placi din beton armat
turnat monolit este de hp 50 mm

-conditie de diafragma orizontala(P100-1/2013):-placile care fac parte din


structuri amplasate in zone seimice unde placile se considera diafragme
orizontale,grosimea minima a placii de beton armat va fi hp 80 mm
-conditie de rezistenta la foc-prin tema de proiect s-a prevazut rezistenta la foc
de 30 minute

hp 60 mm -conf.Tabelul 3.28

Aleg hp 13 cm
Predimensionarea stalp:

-Conditie tehnologice:-considerente practice se stabilesc multiplu de 50 mm


hc , bc -multiplu de 50mm
Conf.P100-1/2013(pct.5.3.2.2) dimensiunea hc , bc mai mare decat 300mm
-conditie de rezistenta la foc:prin tema de proiect s-a prevazut rezistenta la foc
de 120 minute
hc , bc >450 mm ,strat de acoperire 40 mm
-Conditie de ductilitate locala:

d <0.45-pentru elemente de ductilitate inalta d 0.45


hc 50 cm bc 50 cm

Greutatea grinzi transverale:


kN
ggr.T bgs hgs - hp bet = 3.53
m

Created with PTC Mathcad Express. See www.mathcad.com for more information.
hc 50 cm bc 50 cm

Greutatea grinzi transverale:


kN
ggr.T bgs hgs - hp bet = 3.53
m
Greutatea grinzi longitudinal:
kN
ggr.L bgp hgp - hp bet = 6.2
m
Incarcari gravitationale, uniform distribuite pe planseul terasei:
kN
gTerasa 1 gterasa + 0.4 sk = 7.304
m2
Incarcari gravitationale, uniform distribuite pe grinzile perimetrale
peste ultimul etaj:
kN
gAtic 1 gkAtic.P.T = 2.79
m
Incarcari gravitationale, uniform distribuite pe planseul curent:
kN
gPlanseu 1 gplanseu + 0.3 gu + 0.3 gp.despartitori = 8.743
m2
Incarcari gravitationale, uniform perimetrale pester parter(P) si
etaj curent:

kN
gkper.E.T = 9.044 m
m2
kN
gkper.E.L = 9.529 m
m2
kN
gkper.P.T = 11.305 m
m2
kN
gkper.P.L = 11.79 m
m2

Af 31.18 m 2 hsP 4.25 m


lafT 5.50 m hsE 3.55 m
lafL 4.98 m

Nsc1 gTerasa Af + nniv - 1 gPlanseu Af + gkper.E.L lafL + gkper.E.T lafT = 1.337 10 3 kN


Nsc2 gkper.P.L lafL + gkper.P.T lafT + n ggr.T lafT + ggr.L lafL = 573.261 kN
Nsc3 ((n - 1)) hc bc hsE bet + hc bc hsP bet = 204.063 kN
Nsc Nsc1 + Nsc2 + Nsc3 = 2.114 10 3 kN

C25/30 -rezulta
N fck N
fck 25 fcd = 16.667
mm 2 1.5 mm 2

h c = bc

Nsc
= [[ 53.096 ]] cm
d fcd

Aleg stalp : hc 55 cm bc 55 cm

Calculul fortei taietoare de baza:

Created with PTC Mathcad Express. See www.mathcad.com for more information.
hc 55 cm bc 55 cm

Calculul fortei taietoare de baza:


I.e 1.0 (clasa III)

Fb I.e SdT1 m ag 0.40 g


Tc 1.0 s => Tb 0.2 s

H h1util + 3 h2util + 4 hgp + 0.6 m = 15.5 m Td 3.00 s


ct 0.05
3

4
T1 ct H h2util = 2.8 m

T1 0.446 s 0 2.5

TB < T1 < Tc => ((T)) 0

u
q5 q 5.75
1
((T)) m
SdT1 ag = 1.706
q s2
0.85

-ultimul etaj

G4.1 gterasa 470.19 m 2 + 0.3 sk 470.19 m 2 + gAtic 88.9 m + ggr.T 98.8 m + ggr.L 96.9 m
1 1 1
G4.2 gkper.E.T 32.30 m + gkper.E.L 49.4 m + 24 hc bc bet h1util + hgp
2 2 2
G4 G4.1 + G4.2 = 5.316 10 3 kN

-etaj 2-3

G23.1 gplanseu 470.19 m 2 + 0.3 gu 470.19 m 2 + 0.3 gp.despartitori 470.19 m 2

G23.2 ggr.T 98.8 m + ggr.L 96.9 m + gkper.E.T 32.30 m + gkper.E.L 49.4 m + 24 hc bc bet h1util + hgp

G23 G23.1 + G23.2 = 6.594 10 3 kN


-parter
G1.1 gplanseu 470.19 m 2 + 0.3 gu 470.19 m 2 + 0.3 gp.despartitori 470.19 m 2
G1.2 ggr.T 98.8 m + ggr.L 96.9 m + gkper.P.T 32.30 m + gkper.P.L 49.4 m + 24 hc bc bet h1util + hgp

G1 G1.1 + G1.2 = 6.779 10 3 kN

Gtot G1 + 2 G23 + G4 = 2.528 10 4 kN

Created with PTC Mathcad Express. See www.mathcad.com for more information.
Gtot G1 + 2 G23 + G4 = 2.528 10 4 kN
Gtot
masa = 2.578 10 3 tonne
g
Fb I.e SdT1 masa = 3.737 10 3 kN
1.Evaluarea incarcarilor din vant

-cf CR 1-1-4/2012

Valoarea presiunii dinamice de referinta a vantului:


qb 0.6 kPa (figura 2.1)

Lungimea de rugozitate(categorie teren IV)

z0 1 m (tabelul 2.1)

Inaltimea constructiei:

z 15.5 m

Factorul de proportionalitate:

2.12 2
= 2.12 (tabelul 2.3)

Intensitatea turbulentei:

(relatia 2.11)


Ivz = 0.309
z
2.5 ln
z0

Factorul de varf:

g 3.5

Factorul de rafala:

cpv ((z)) 1 + g Ivz = 2.083 relatia 2.14

Factorul de rugozitate:
kr 0.233
2
2 z
crz kr ln = 0.408
z0

Created with PTC Mathcad Express. See www.mathcad.com for more information.
2
2 z
crz kr ln = 0.408
z0

Valoarea de varf a presiunii dinamice a vantului:


kN
qpz cpv ((z)) crz qb = 0.51
m2
Factorul de importanta-expunere: Iw 1.15 (CLASA II)

a)Vantul actioneaza pe directia transversala a cladirii: h 15.5 m


h<b => ze h b 27.10 m

e min ((b , 2 h))

e = 27.1 m
e
= 5.42 m
5

4
4 = 3.2
5

h
= 2.331
d

Created with PTC Mathcad Express. See www.mathcad.com for more information.
h
= 2.331
d

ZONA A: cpe.10A -1.2

ZONA B: cpe.10B -0.8

ZONA D: cpe.10D 0.8

ZONA E: cpe.10E -0.566

ZONA A: we Iw cpe.10A qpz = -0.703 kPa

ZONA B: we Iw cpe.10B qpz = -0.469 kPa

ZONA D: we Iw cpe.10D qpz = 0.469 kPa

ZONA E: we Iw cpe.10E qpz = -0.332 kPa

a)Vantul actioneaza pe directia longitudinala a cladirii:

b 17.35 m d 27.10 m

h 15.5 m

e min ((b , 2 h)) = 17.35 m


e 4
= 3.47 m e = 13.88 m d - e = 9.75 m
5 5

Created with PTC Mathcad Express. See www.mathcad.com for more information.
2
2 z
crz kr ln = 0.408
z0
Valoarea de varf a presiunii dinamice a vantului:
h
= 0.572
d
kN
qpz cpv ((z)) crz qb = 0.51
m2

ZONA A: cpe.10A -1.2

ZONA B: cpe.10B -0.8

ZONA C: cpe.10C -0.5

ZONA D: cpe.10D 0.743

ZONA E: cpe.10E -0.385

ZONA A: we Iw cpe.10A qpz = -0.703 kPa

Created with PTC Mathcad Express. See www.mathcad.com for more information.
ZONA A: we Iw cpe.10A qpz = -0.703 kPa

ZONA B: we Iw cpe.10B qpz = -0.469 kPa

ZONA C: we Iw cpe.10C qpz = -0.293 kPa

ZONA D: we Iw cpe.10D qpz = 0.435 kPa

ZONA E: we Iw cpe.10E qpz = -0.226 kPa

Calculul presiunii vantului la acoperisurile plate:

a) directia transversala a cladirii:

b 27.10 m

h 15.5 m

e min ((b , 2 h)) = 27.1 m


e e e
= 6.775 m = 2.71 m = 13.55 m
4 10 2

hp 0.6 m

Created with PTC Mathcad Express. See www.mathcad.com for more information.
hp 0.6 m
hp
= 0.039
h
ZONA F: cpe.10F -1.59

ZONA G: cpe.10G -1.09

ZONA H: cpe.10H -0.7

ZONA I: cpe.10I -0.2

ZONA F: we Iw cpe.10F qpz = -0.932 kPa

ZONA G: we Iw cpe.10G qpz = -0.639 kPa

ZONA H: we Iw cpe.10H qpz = -0.41 kPa

ZONA I: we Iw cpe.10I qpz = -0.117 kPa

b) directia longitudinala a cladirii:

b 17.35 m h 15.5 m

d 27.10 m

e min ((b , 2 h)) = 17.35 m


e e e
= 4.338 m = 8.675 m = 1.735 m
4 2 10

Created with PTC Mathcad Express. See www.mathcad.com for more information.
ZONA F: cpe.1F -1.59

ZONA G: cpe.10G -1.09

ZONA H: cpe.10H -0.7

ZONA I: cpe.10I -0.2

ZONA F: we Iw cpe.10F qpz = -0.932 kPa

ZONA G: we Iw cpe.10G qpz = -0.639 kPa

ZONA H: we Iw cpe.10H qpz = -0.41 kPa

ZONA I: we Iw cpe.10I qpz = -0.117 kPa

ZONA I: we Iw cpe.10I qpz = -0.117 kPa

Created with PTC Mathcad Express. See www.mathcad.com for more information.