Sunteți pe pagina 1din 2

Butnaru Alexandru

IPSE
N=7

TEST FINAL MASTER IPSE, martie 2020

Se da un transformator trifazat, cu urmatoarele date nominale si de catalog:


a) Sn=N*500=7*500=3500 (VA), U1n=600V (conexiune
triunghi),U2n=300V(conexiune stea)
unde N este numarul de ordine din catalog
b) pkn=0.06u.r; ukn=0.1u.r; pon=0.02u.r; ion=0.1u.r
Se cer urmatoarele:
I. Date nominale
1. Calculati: a) I1,n= Sn/U1n = 3500/600=5.83(A),
I1,n,f=Sn/sqrt3*U1n=3500/1.73*600=3.43(A), b) I2,n= Sn/U2n = 3500/300=11.68(A),
I2,n,f=I2,n=11.68(A)
2. Calculati: a) R1=r1*Z1n=0.03*103=3.1(  ), Z1n = U1n/I1n=600/5.83=103(  ),
r1 = R1 / Z 1,n  r2, = R2, / Z 1, n  p k ,n / 2 = 0.06/2=0.03 b) R2= R2, / k w2 =3.1/4= 0.775 (  ),
R2,  r2,  Z 1,n = 0.03*103=3.1(  ), kW  w1 / w2  U 1, n / U 2,n =600/300=2, stiind ca
PJ,1,n=PJ,2,n=Pk,n/2=210/2=105(W), Pkn=pkn*Sn=0.06*3500=210(W)
3. Calculati:
a) Consumul propriu (intern) de energie electrica activa(Pkn si Pon),in T=24 ore, la
functionarea in regim nominal, (   I 2 / I 2,n  I 1 / I 1,n =1) ,
Whn=Pkn*T=210*24=5.04kWh, Whn=Pon*T=70*24=1.68kWh,
Pon=pon*Sn=70(W)
b) Idem la functionarea in sarcina optima,     p / p =0.58, Whm=2.61kWh
m o,n k ,n

II. Determinarea experimentala a rezistentelor infasurarilor R1, R2


4. Dimensionarea schemei de executie (metoda A,V, tensiunea sursei c.c, UC=100V)
a) pentru Rx=R1, Ix=0.5I1,n=0.5*5.83=2.92(A), Rp,max= Uc/Ic=100/2.92=34.25(  ),
, Ip,max=2.92A?
b) pentru Rx=R2, Ix=0.5I2,n=0.5*11.68=5.84(A), Rp,max= Uc/Ic=100/5.84=17.12( 
), Ip,max=5.84A?
5. Masuratori estimate
a) Ax,1 =6A, Vx,1=200V,
b) Ax,2=12A, Vx,2=200V,
6. Rezultate estimate: a) R1=  , R2=  , respectiv r1 =….u.r, r2, =….u.r

III. Incercarea la mersul in gol, nominal

7. Definitii, valori uzuale(in u.r),semnificatii fizice


8. Dimensionarea schemei de executie(A,V,W) si estimare masuratori,in 2 variante:
a) alimentare infasurare I.T(Uo=U1,n=600V, I2=0), Ao,1=11A, Vo,1=1200V,
Wo,1=1200/11=109.1W
b) alimentare infasurare J.T(Uo=U2,n=300V,I1=0), Ao,2=6A,Vo,2=600V,
W0,2=600/6=100W
9. Marimi calculate:
a) alimentare infasurare I.T (600V)
U 1,o =…..V, I 1, 0 =……A, P1,o =…..W , io , n =…..u.r, p o , n =…..u.r, cos  o, n
=….,
b) alimentare infasurare J.T (300V)
U 1,o =…..V, I 1, 0 =……A, P1,o =…..W , io , n =…..u.r, p o , n =…..u.r, cos  o, n
=….,