In cazul simularii redresorului monofazat s-au folosit urmatoarele valori:
Usursa = 230 [V];
f =50 [Hz];
L1 = 3 x 10 [mH];
Rs = 45 [];
Cs = 10 [mF];
= 30 [grade]
Amplitudine [A]
Ordinal Frecventa
armonicii
[Hz]
R
S
1
50
7.078
7.08066
3
150
0.005078
0.001949
5
250
1.05107
1.04745
7
350
0.473411
0.477235
9
450
0.003156
0.002661
11
550
0.132818
0.13394
13
650
0.084269
0.08627
15
750
0.002058
0.001753
17
850
0.06153
0.062412
19
950
0.054577
0.055276
THD
Calculat 0.164787694 0.164534
THD
Masurat
0.164885
0.162792
Puteri
30
45
60
75
90
P
2255.17
2078.53
1691.72
1169.1
633.136
Q
706.862
896.671
1125.39
1218.8
1079.79
R
0.164885
0.207961
0.260682
0.321833
0.415519
THD
S
0.162792
0.207167
0.263281
0.324355
0.418476
T
7.08317
0.004799
1.05025
0.478597
0.000852
0.134329
0.087279
0.000568
0.062285
0.056949
0.164938
0.1663
T
0.1663
0.209383
0.265474
0.324019
0.415378
Puteri
2000
1500
P
1000
Q
500
0
0
20
40
60
80
100
0.3
0.25
THD R
0.2
THD S
0.15
THD T
0.1
0.05
0
0
20
40
60
80
100
Observatii si concluzii
Din graficele de dependenta a puterii / factorului THD si unghiul de comanda observam ca la
crestrea unghiului de comanda performantele sistemului si calitatea curentului electric absorbit de la retea
scad. In momentul conectarii altor consumatori (receptori) la un redresor comandat (sarcina neliniara)
acestia vor fi influentati de modul de operare al redresoarelor.
La modificarea unghiului de comanda factorul THD are valori aproximativ egale pe toate cele trei
faze R, S si T ceea ce ar insemna un sistem echilibrat