H (25 10) 5 20 m
g
g
70
60
50
[%]
40
H [m]
30
20
H H =H (Q)
s inst inst
10
0
0 0.005 0.01 0.015 0.02 0.025 0.03
3
Q [m /s]
2. Caracteristicile celor 2 pompe
Q1 Q0 H1 50 65000 Q12
H1 H 0
1 7700 Q1 260000 Q12
1 0 Q0
Q2 r2 Q0 0,9 Q0
H 2 50 0,92 65000 0,9 2 Q02
H 2 r H 0 0,9 H 0
2
2 2
70
60
= (Q )
1 1 1
50
= (Q ) cu relatia (1)
[%]
2 2 2
40
H [m]
30
H = H (Q )
1 1 1
H =H (Q )
20 red1 red1 1
H H =H (Q) H = H (Q )
s inst inst 2 2 2
H =H (Q )
red2 red2 2
10
0
0 0.005 0.01 0.015 0.02 0.025 0.03
3
Q [m /s]
4. Caracteristica energetică a cuplajului paralel
• se consideră valori de referință ale sarcinii, Href (unde Href 40,5 m),
pentru care Hred 1 = Hred 2 = Href
50 H red1 H cp H ref
Q1
72000 50 H ref 40,5 H ref
Q Q1 Q2
40,5 H red 2 72000 72000
Q2
72000
1 F1 F1 F1
total 1 2
60 = 56.93%
F1
= (Q )
1 1 1
= 53.87%
F2
50
= (Q ) cu relatia (1)
2 2 2
40
H = 34.69 m F F F
F1 2 1
H = 33.77 m
F2
30 H = 33.04 m
F
H = H (Q)
cp cp
H = H (Q )
1 1 1
H =H (Q )
20 red1 red1 1
H H =H (Q) H = H (Q )
s inst inst 2 2 2
H =H (Q )
red2 red2 2
10
3
Q = 0.0153 m /s
F1
0
0 0.005 0.01 0.015 0.02 0.025 0.03
3 3
Q = 0.0102 m /s Q [m3/s] Q = 0.0255 m /s
F2 F
5. Puterea totală consumată pentru pompare
QF 1 H F 1 0,0153 34,69
P1 9,81 [kW ] 9,81 9,17 kW
F1 0.5693
QF 2 H F 2
P2 9,81 [kW ]
F 2
Ptotal P1 P2 [kW ]
Se dau următoarele
valori:
zi = 0 m; ze = 5 m;
pi/g = 10,17 m;
pe/g = 30,17 m;
za1 = za2 = 3 m;
pv/g = 0,17 m;
Înălțimea statică: H s
pe pi z zi 30,17 10,17 5 0 25 m
e
g
NPSHinst1
pabsi pv H M1a Q12
ga
g
10,17 0,17 3 6000 Q12 7 6000 Q12
NPSHinst 2
pabsi pv H M 2aQ22
ga
g
10,17 0,17 3 6000 Q22 7 6000 Q22
QF1 < Qlim și QF2 < Qlim pompele nu cavitează
F1
60
60
(Q
(Q )) (Q
(Q ))
F2 11 11 22 22
50
50
H
H (Q)
(Q)
cp
cp
[%], H [m], NPSH [m]
H F
F22
F2 F
F11
40
40 F
F
H
H
F
F
30
30
H
H (Q)
(Q) H (Q )) H
H (Q H (Q
(Q ))
inst
inst 11 11 22 22
20
20 H
H (Q
(Q ))
red1
red1 11
H
H (Q
(Q ))
red2
red2 22
10
10 NPSH (Q )
inst j j C1 C2
NPSH (Q ) Q
Q
j j F
F
00
00 0.005
0.005 0.01
0.01 Q
Q Q
Q 0.015
0.015 Q 0.02
0.02 0.025
0.025 0.03
0.03
F2
F2 F1
F1 lim Q [m33/s]
Q [m /s]
4. Puterea totală consumată pentru pompare
QF 1 H F 1
P1 9,81 [kW ]
F1
QF 2 H F 2
P2 9,81 [kW ]
F 2
Ptotal P1 P2 [kW ]