-Calculul la condens :
* pe suprafaa elementelor de nchidere;
Suprafaa pereilor:
Sper=Pint*hi-St T=59,6 13,87-96,48=730,17m2
Sper =730,17m2
Pint-perimetrul interior;
St T-suprafaa total a tamplriei.
Aria total:
A= Sper+ St T+ Spl+ Spl inf
A=730, 17+96,48+2*198=1222,65m2
=0,445
INALI
ME
PERIMET
RU
PERIMET
ARI RU
E
TOTAL
ARIA
NR
TOTAL ELEMEN
A
TE
F1
0.6
0.6
2.4 0.36
24
3.6
10
F2
1.2
1.2
4.8 1.44
67.2
20.16
14
F3
2.4
1.2
7.2 2.88
72
28.8
10
F4
1.5
1.2
5.4
1.8
54
18
10
F5
0.9
1.2
4.2 1.08
42
10.8
10
U1
0.7
2.1
5.6 1.47
44.8
11.76
U2
1.6
2.1
7.4 3.36
TOTAL
7.4
347.4
3.36
96.48
[m2K/w] unde:
PERETE EXTERIOR:
Nr.
Denumire strat de
Grosimea
Conductivitatea
d/
crt
material
d(m)
(w/mk)
(m2k/w)
0,015
0,87
0,017
0,25
0,24
1,04
0,15
0,04
3,75
2
3
Tencuiala interioara
M50T
Zidarie de umplutura din
BCA(GBN35)
Izolaie termic
Tencuial exterioar
4
(tencuiala minerala
0,005
0,93
0,005
armata)
5
0,042
0,125
1 1
= = 0.125
i 8
1
1
RSe =
=
= 0.042
e 24
RSi =
(conform C107/3-97)
= 3,6m K/W
x=0,104adoptam x=0,15m
Ref =0,125+0,017 +1,04+3,75+0,005+0,042= 4,98 m2K/W > Rnec=1,8
m2K/W
Rnec=2 Rmin=21,8=3,6 m2K/W
Dimensionarea termoizolatiei:
= + + =10 m2K/W
+ 0.03 + 0.042 =
Nr.
Crt.
0
1
2
3
1
Tencuial tavan-mortar ciment i
var
Plac din beton armat
ap de egalizare din mortar de
ciment
d
(m)
d/
(W/mK) (m2K/W)
0,015
0,87
0,017
0,13
1,74
0,074
0,03
0,93
0,032
Barier de vapori
0.18
Strat de pant-bca
0,08
0,24
0,333
0,03
0,93
0,032
0,35
0,044
7.95
0,03
0,93
0,032
6
7
8
9
10
Hidroizolaie
11
Nisip
0,03
12
Pietri
0,03
13
0.042
14
0.125
(d/)
8.63
Nr.
Denumire strat de
Strat
material
Strat de uzura(placa
d (m)
[w/mk]
d/ [m2k/w]
0.015
2.03
0.007
ceramica+adeziv )
2
0.03
0.93
0.032
0.13
1.74
0.074
0.25
0.044
5.68
0.013
0.41
0.03
PEX
5
Ri = 0.167 m2K/W
Ri = 0.083 m2K/W
+ 0.03 + 0.083 =
5.8m K/W
x=0.26adoptam x=0.25m
Ref=6.07m2K/W R nec=2.9m2K/W
c.Determinarea rezistenei termice specifice corectate:
Se utilizeaz metoda coeficienilor specifici liniari i punctuali de transfer
termic .Calculul
termice ce aparin anvelopei cldirii (pereii exterior cat si planeele peste ultimul
nivel respective peste subsol).
Parter: 4h =42,67=10,68 m
Etaj: 4h n =42,804=44,8
m
L=55,48 m
= =0,1W/mK
=0
P.T. curenta
Parter: 3h =32,67=8.01 m
Etaj: 3h
n =32,804=33,6m
L=8,01+33,6=41,61 m
= =0,01W/mK
P.T curent in T
= =0,01W/mK
Etaj: 5h n =5(2,805-0,13)=513,87=69,35 m
L=4Pint=459,7=238,8 m
= =0,05W/mK
P.T. soclu
L=Pint=59,7m
= 0,1W/mK
+ = 0,32W/mK
P.T atic
L=Pint=59,7m
= 0,15W/mK
P.T curenta+balcon :
L=5.724=45.6 m
= =0,4 W/mK
Contur tamplatie :
=0,16 W/mK
L= Ptampl= 347.4 m
+ =0,35W/ mK
1 L
+
U ' = +
R
A
A
R ' = 1
U'
unde:
se neglijeaza.
Element
Puni termice
U'
R'
4.9
0.37
2.64
55.4
RV col ieind
0.2
11.096
55.4
41.6
RV curent
0.02
0.8322
PERETE EXTERIOR
69.3
RV curent n T
0.02
1.387
238.
RO curent
0.05
11.94
RO soclu
0.1
59.7
5.97
RO atic
0.1
59.7
5.97
0.8
45.6
36.48
RO
curent+balcon
347.
Contur tamplrie
0.16
55.584
129.25
A=731.56mp
Planeu
superior
RO atic
0.15
59.7
A=198,99mp
8.955 8.6
3
8.955
0.32 59.7
19.104
RO perei
28.8
10.097
portani
0.35
0.16
6.21
6.0
0.31
3.21
29.201
A=198,99mp
G=
Vnclzit
A
A
A
3
perei opaci 1 + teras 2 + tmplrie 3 + placa 4 + 0,34 n GN [W(/m K)]
R 'teras
R 'tmplrie
R ' placa
n care:
V volumul nclzit, calculat pe baza dimensiunilor interioare ale cldirii,
[m3];
Perete exterior
Ri'
A /Ri'
731.56
2.649
1 276.159
198.99
6.216
32.013
198.99
3.210
0.395
24.484
96.48
0.5
192.96
Planseu
superior
PLanseu
inferior
Tamplrie
525.615
Se alege n=0,5 conform C107/4-2005.
G=0.36 [W(/m3K)]
GN=0,438 W/(m3K)> G=0.36 [W(/m3K)]