Sunteți pe pagina 1din 1

6 .

9
0

C
E
RD
VE N
NA

A
E
ZO
N
D
IN
A
RD
JA

R
9
5.9
N
E
8 A NT

R
9

E
LE

R
L
CA

A
A
ZO

N
NA

D
VE
NO

NE
RD

N
E

B
ZO

O
A

NA

E
N

2
VE
D

RD
E

A
N

SE

SO
N

N
C

D
A
E
RD

E
VE N
A

NZ
NA E

N
ZO N D
A I N
RD
R

JA S
NT
E
A
R

A
M
E
R

P10
28
A

625
E
OT LOCALIZACIÓN
5

L
A

1 29
NA
C

27

TZ 2X1
E
28

TZ
TE OT
A

2X /0+1
ZA
.00

L
LO
R

4+
30

28
N

4 A /0
R

TE
MA 26

.00

P
LO
E

P6 T E
R

625 LO
31
A

10 25 TE
TE TE LO
5

LO LO P9
32 626
11 24 E
E
9
T E TE LOT
TZ 2X1

T
TZ

LO LO LO
2X /0+

12 33
4+ 1/0

23 E
28

TZ 2X1
OT
4A

TE

TZ
TE TE
.0

2X /0+1
LO
P

O LO
X
0

L
X

4+
X
X

34
X
X
X
X

29
X
X
X

13
X
X

4 A /0
X

P3E
X

22 TE
X
X

.40
7 TE
X

P
P5
X

TE LO
X

523A E
X

LO
X

OT LO
X

626
X

625 35
X

L
X

14
X
X

TE
X

21
X

TE
X

6 O RD
E
X

VE
X

TE E L N
X

NA

LO
E
X

OT
ZO D
X

2
X

N
TZ 2X

LO
X

A
8.0
X

L
X

TZ

36
X

2X 4+4
X

15
X

P8
X

20
0

E 40
1/0 A
X

5 T
TE
X

O .
X

E 16 625/625
X

TE
LIN

TZ 2X1
+1 P
X

OT L
X

LO
229X4+4/0+1/0
X

/0
TZ
/0
X

LO +2
EA

L
X

2/0 4 AP
X

16
.40 AP
X

X
EX

2 +
X

19 TZ 2X4
X

4 TE
X

X
IST

E TZ
X

LO E
X

OT OT
X

X
EN

L L 60
X

P2 P7
X
TE

17 3.
X

626 3 2 626
X
DE

/0
TE
X

TE +2
X

2/0 AP
X

O
ME

LO L
X

X +4
X

2
X

TZ 2X4
X
D

18 0
X

X
IA

TZ 1
X

E
X
TE

2 E
X

OT
X

E L
X
N

L
X

T L
X

29
SIO

LO
TZ 2X4
X

P4 A
X

TZ
X

.40

C
N

RED M.T. EXISTENTE 13.2 KV ESSA


2X +4 A
X

626
X

1 SUBESTACION: SAN MARTIN -/- CIRCUITO:56-501 SAN MARTIN


X

1
2.8
X

1/0 P

NUMERO DE APOYO: 9914277


X

TE
X

3
X

+1
X

/0
X

O
X

L +2
X

/0
X

2/0 AP
X

X +4
CONECTOR COMPRESION TIPO H
X

N
2
X

E ESTRIBO PARA LÍNEA ENERGIZADA

TZ 2X4
X

D
X

N
X

A
X

TZ
X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

P1E
X
X

CORTACIRCUITO 15 KV - 100 A CORTACIRCUITO 15 KV - 100 A


X

2 X 6 AMP - TIPO H
X

2 X 5 AMP - TIPO K
X

523A/710
X
X

Punto de Apoyo
X
X
X

625/625
X
X
X
X

9914277
X
X
X

T1 PROY
X

75 KVA 1Ø
X

PARARRAYOS 12 KV / 10 KA POLIMERICO
X

13.200/240-120 v
X

SOBRE LA CUBA DEL TRANSFORMADOR


X

TRANSFORMADOR 2F 75 KVA
X

13200/120-240 V
X

AEREO TIPO POSTE


X

SUMERGIDO EN ACEITE ONAN


X

Red de Baja Tensión


X

Trenzado 2x2/0+2/0 xlpe


X

Red de Baja Tensión


X

Trenzado 2x4+4 xlpe A.P.


X

MEDIDOR TIPO 2 MONOFÁSICO


X

TRIFILAR ALUMBRADO PUBLICO


X

TIPO CONEXION DIRECTA 240/120V


X

POSTE EXISTENTE
X

ESTRUCTURA NC-RA2-301
NC-RA2-907 MONOFÁSICA
SUBEST. AEREA
PRESENTA:
CONVENCIONES: POSTE DE CONCRETO EXISTENTE 8m 510Kg POSTE DE CONCRETO EXISTENTE 12m 1050Kg OBSERVACIONES: MODIFICACIONES:
E
LMT AEREA MEDIA TENSION EXISTENTE M.P. SN 205-28580
1. TODAS LAS LUMINARIAS SON NUEVAS.
X
POSTE DE CONCRETO PROYECTADO 8m 510Kg
POSTE DE CONCRETO PROYECTADO 12m 1050Kg PROPIETARIO:
XX
LMT AEREA MEDIA TENSION PROYECTADA
POSTE DE CONCRETO EXISTENTE 8m 750Kg P PAOLA ANDREA VARGAS
XX
LMT AEREA MEDIA TENSION PROYECTADA CABLE ECOLOGICO
POSTE DE CONCRETO PROYECTADO 8m 750Kg POSTE DE CONCRETO EXISTENTE 12m 1500Kg
LBT AEREA TRENZADA CUADRUPLEX 3x2/0+1/0 E
CABLE TRENZADO 2x1/0"+1/0. PROYECTO:
LBT AEREA TRENZADA CUADRUPLEX 3x1/0+1/0 POSTE DE CONCRETO EXISTENTE 8m 1050Kg
POSTE DE CONCRETO PROYECTADO 12m 1500Kg
P CALLE 10 CON CARRERA 5 MUNICIPIO DE SAN MARTIN - CESAR
LBT AEREA TRENZADA EXISTENTE POSTE DE CONCRETO PROYECTADO 8m 1050Kg
POSTE DE CONCRETO EXISTENTE 12m 2000Kg CONTIENE:
TRANSFORMADOR EXISTENTE POSTE DE CONCRETO EXISTENTE 8m 1500Kg E

POSTE DE CONCRETO PROYECTADO 8m 1500Kg POSTE DE CONCRETO PROYECTADO 12m 2000Kg ING. WILLIAM HERRARA FECHA: PLANO DE No. De Factibilidad
TRANSFORMADOR PROYECTADO P
3. ALUMBRADO PUBLICO ES RESPONSABILIDAD DE LA
POSTE DE CONCRETO EXISTENTE 12m 510Kg CARLOS CASTRO AGOSTO DE 2021 1 2 .
LUMINARIAS SODIO 70 W EXISTENTES POSTE DE CONCRETO EXISTENTE 14m 1050Kg APROBACIÓN:
E ESCALA:
POSTE DE CONCRETO PROYECTADO 12m 510Kg
SPT POSTE DE CONCRETO PROYECTADO 14m 1050Kg 1 : 500
P
POSTE DE CONCRETO EXISTENTE 12m 750Kg
POSTE DE CONCRETO PROYECTADO 12m 1350Kg
P

10 CANTIDAD DE USUARIOS EXISTENTES POSTE DE CONCRETO PROYECTADO 12m 750Kg POSTE DE CONCRETO PROYECTADO 14m 1350Kg
P P FIRMA

S-ar putea să vă placă și