Sunteți pe pagina 1din 4

1 EVALUAREA INCARCARILOR

gk gama G gama Q gLD gSD


utila 2.5 0.3 1.5 0.75 3.75
zapada 2 0.4 1.5 0.8 3

compartimentari si pardoseala 3.5 1 1.35 3.5 4.725


inchideri (pereti grei) 4.6 1 1.35 4.6 6.21
finisaje 2 1 1.35 2 2.7
parapet 2.5 1 1.35 2.5 3.375

2 PREDIMENSIONAREA ELEMENTELOR
A PLACA Hp P/180+10..20mm
CLASIC
conditie de rigiditate BxH mp Perimetru hp min (cm) l min/40
perioada proprie a planseului <0.25s 9x9 81 36 22 22.5
8x8 64 32 20 20
7x7 49 28 18 17.5
6x7 42 26 16 15
6x6 36 24 15 15
5x6 30 22 14 12.5
planseu dala 5x5 25 20 13 12.5

conditie fonica hp min 13cm

B GRINZI
conditia de rigiditate (in special laterala a structurii)
Hmin L L/12 L/10 L/8
9 75 90 113
8 67 80 100
7 58 70 88
6 50 60 75
5 42 50 63
4 33 40 50
3 25 30 38

C STALPI
conditia de ductilitate limiteaza forta axiala la 40% din fcd

daN/mp A daN
nivel curent g placa 20 500 25 12500
finisaje si 350 25 8750
incarcare ut 250 25 1875

b h L
g grinda 0.25 0.5 10 3125
g stalp 0.4 0.4 3 1200
27450

5 niveluri 137250
b stalp h stalp fcd miu
45 45 20 0.34

ductilitatea inseamna... deformatia ultima/deformatia la curgere


miu ... limiteaza zona comprimata
de ce zapada e 0.4?

gruparea de lunga durata aplicata cu coeficienti mai mici


gruparea de scurta durata aplicata cu coeficenti mai mari (un fel de soc pentru structura)

DALA cu grinzi perimetrale


l min/33
27
24
21
18
18
15
15

hp dala min = 15cm

b min 0.5H 0.33H


b min 200 mm
daN

daN