Sunteți pe pagina 1din 20

~Tema 2~

-studiu de caz individualIntegrarea surselor regenerabile de energie n cldiri nZEB

S se studieze eficiena energetic a unor colectoare solare fotovoltaice sau


termice, integrate n construcia unei locuine unifamiliare, amplasate n Cluj-Napoca.

Locuinta unifamiliara avand regim de inaltime S+P+E, cu acoperis de tip terasa. Solutia
aleasa de colectoare solare fotovoltaice sau termice se va monta pe acoperisul de tip terasa.

Contents
Poziia (orientarea) colectorilor / captatorilor pe acoperi sau pe diverse elemente arhitecturale
ale cldirii.................................................................................................................................... 2
ANALIZA GRAFICA.................................................................................................................... 2
ANALIZA VALORICA.................................................................................................................. 6
Influena unui sistem de urmrire (tracking) a Soarelui pe cer;................................................10
Numrul (suprafaa colectorilor / captatorilor);.........................................................................11
Dimensionarea colectorilor solari termici :............................................................................. 11
Dimensionarea colectorilor solari electrici:........................................................................... 13

arh. Ioana Dorina BURCEZAN

Poziia (orientarea) colectorilor / captatorilor pe acoperi sau pe


diverse elemente arhitecturale ale cldirii
ANALIZA GRAFICA
t =0-orizontal / t =0-SUD

t =30 / t =0-SUD

t =35 / t =0-SUD

t =37.5/ t =0-SUD

t =40 / t =0-SUD

arh. Ioana Dorina BURCEZAN

t =45 / t =0-SUD

t =60 / t =0-SUD

t =90 / t =0-SUD

Din studiul graficelor de mai sus se poate observa ca pozitia optima (inclinarea optima) a panourilor orientate spre
S este de 37.5o.
-Randamentul electric maxim martie= 30o-45o / -Randamentul maxim electric iunie= 30o-45o
-Randamentul termic martie= 30o-45o / -Randamentul termic iunie= 600
t =0-orizontal
t =90-VEST

arh. Ioana Dorina BURCEZAN

t =30
t =90-VEST

t =35
t =90-VEST

t =37.5
t =90-VEST

t =40
t =90-VEST

arh. Ioana Dorina BURCEZAN

t =45
t =90-VEST

t =60
t =90-VEST

t =90
t =90-VEST

-Din studiul graficelor de mai sus se poate observa ca pozitia optima (inclinarea optima) a panourilor orientate spre
V este de 30o -40o.

In luna martie randamentul colectorilor electrici este mai bun, dar in luna iunie eficienta colectorilor
termici este mai optima, dar in luna iunie eficienta colectorilor termici este mai optima,si a scazut fata
de luna martie si eficienta colectorilor electrici.

t =0-orizontal
t =270-EST

arh. Ioana Dorina BURCEZAN

t =30
t =270-EST

t =35
t =270-EST

t =37.5
t =270-EST

t =40
t =270-EST

arh. Ioana Dorina BURCEZAN

t =45
t =270-EST

t =60
t =270-EST

t =90
t =90-VEST

-Din studiul graficelor de mai sus se poate observa ca pozitia optima (inclinarea optima) a panourilor
orientate spre E este de 30o -40o. In luna martie randamentul colectorilor electrici este mai bun, dar in
luna iunie eficienta colectorilor termici este mai optima, dar a crescut fata de luna martie si eficienta
colectorilor electrici.

t =37.5
t =0-SUD

arh. Ioana Dorina BURCEZAN

t =37.5
t =90-VEST

t =37.5
t =270-EST

Pozitia optima a panourilor solare din studiul graficelor alaturate reiese ca ar fi


37.5 orientare Sudica, cu exceptia eficientei colectorilor electrici care au valori mai
mari in luna martie avand orientare Vestica.
0

ANALIZA VALORICA
-

Valorile s-au extras din fisierul A2_radiatie_suprafete_inclinate_tema.xlsx, sheet:


CALCULATION.
arh. Ioana Dorina BURCEZAN

Pentru precizie s-a ales si analiza valorica a pozitiei si orientarii colectorilor solari in
functie de Igt (radiatia solara global ape o suprafata inclinata[W/m2])

arh. Ioana Dorina BURCEZAN

arh. Ioana Dorina BURCEZAN

arh. Ioana Dorina BURCEZAN

In tabelele de mai jos s-au extras valorile medii maxime in functie de inclinari de 0 o,30
o
,35 o,37.50 o,40 o,45 o,
60 o,90 o pe cele 3 orientari : Sud, Vest, Est
Se poate observa ca la inclinarea de 300, orientare Sudica avem Igt mediu maxim (radiatia
solara global ape o
suprafata inclinata[W/m2])

arh. Ioana Dorina BURCEZAN


t t

Igt
(tot
al/a
n)
Kw/
mp

Igt
(medi
e/zi/a
n)
Kw/m
p

0 0 124
5.7
02
9 124
0 5.7
02
2 124
7 5.7
0 02

3.460

3.460
3.460

Igt
(tota
l/an)
Kw/
mp

Igt
(medie/
zi/an)
Kw/mp

3 0
0
9
0
2
7
0

1369
.068
1252
.734
1022
.935

3.802

Igt
(total
/an)
Kw/m
p

Igt
(medie/
zi/an)
Kw/mp

3
5

1361.
106
1231.
368
981.0
60

3.780

9
0
2
7
0
t

3.479
2.841

Igt
(total/
an)
Kw/m

3.420
2.725

Igt
(medie/zi
/an)
arh. Ioana Dorina BURCEZAN

37
.5

0
9
0
2
7
0

Kw/mp

1353.
981
1218.
756
959.3
31

3.761
3.385
2.664

Igt
(total/a
n)
Kw/mp

Igt
(medie/zi/
an)
Kw/mp

4
0

1344.75
8
1204.68
9
937.180
4

3.735

90
27
0

3.346
2.603

Igt
(total/an
) Kw/mp

Igt
(medie/zi/
an)
Kw/mp

4
5

1320.08
4
1173.29
6
893.529

3.666

90
27
0

3.259
2.482

Igt
(total/an
) Kw/mp

Igt
(medie/zi/
an)
Kw/mp

6
0

1198.91
9
1054.30
4
755.110

3.330

90
27
0

2.928
2.097

arh. Ioana Dorina BURCEZAN

Igt
(total/an
) Kw/mp

Igt
(medie/zi/
an) Kw/mp

9
0

0
90
27
0

786.536
731.044
461.625

2.184
2.030
1.282

arh. Ioana Dorina BURCEZAN

Influena unui sistem de urmrire (tracking) a Soarelui pe cer;

Daca analizam tebelul de mai sus observam ca valorile maxime sunt in perioada de
vara, dar pentru orientarea colectorilor solari termici si electrici vom avea un exces de energie
oricum in aceasta perioada, deci orientarea si dimensionarea lor trebuie sa fie optima pentru
celelalte perioade ale anului, primavera-toamna si daca se poate si iarna, cand valorile sunt
destul de scazute.
Scopul unui system de tracking solar este pentru obtinerea unei eficiente maxime
pentru un sistem de generare a energiei electrice cu panouri solare. Un dispozitiv de tracking
are doua grade de libertate, comandate de doua servomotoare care actioneaza pe directii
perpendiculare, simuland miscarea soarelui pe parcursul unei zile si deplasarea de la o zi la
alta
Maximizarea aportului de energie solar la producerea apei calde menajere i
nclzirea spaiilor conduce la necesitatea utilizrii sistemelor de orientare solar i pentru
colectoarele solar-termice. Scopul sistemelor de orientare este de a minimiza unghiul de
inciden, format ntre raza solar i normala la panoul solar. n acest fel, sistemele de
orientare cresc cantitatea de energie captat de colector, reducnd astfel i suprafaa total
de colectoare necesar pentru a acoperi necesarul termic dorit.

Numrul (suprafaa colectorilor / captatorilor);


Dimensionarea colectorilor solari termici :
Dimensionarea optim a suprafeei de captare este necesar pentru a asigura producia
de energie termic cu o eficien ct mai ridicat n timpul exploatrii sistemului termic solar.
Se va aproxima necesarul de ap cald pentru patru persoane este de 270 l/zi pentru
care energia zilnic necesar nclzirii de la 10 0C la 45 0C este n medie de 11 kWh/zi. La
dimensionarea captatoarelor solare se va lua n considerare energia zilnic necesar i
energia solar zilnic disponibil pentru locaia dat.
S-a ales tipul de collector solar termic:
VACUUM TUBE COLLECTOR : VITOSOL 300-T, type SP3A Viessmann
Randament 80.40% / K1=1.33[W/(m2K2)] / K2=0.0067[W/(m2K2)] / tmw=85 [oC]
VALORI pt 1 COLECTOR

VALORI pt 2 COLECTORI

Pentru colectorii solari termici solutia aleasa este de 2 colectori solari termici, VITOSOL
300-T, type SP3A Viessmann, pozitionati cu inclinare de 37,5 o, orientare SUDICA, dimensionare
aleasa in functie de luna martie din an.
Analiznd variaia energiei solare disponibile pe perioada anului reiese c pentru
asigurarea energiei necesare pe timp de var avem nevoie de o suprafa minim de captare
iar pe timp de iarn pentru acoperirea deficitului de energie suprafaa de captare trebuie
mrit pentru a compensa scderea energiei solare disponibile.
Din punct de vedere ethnic este imposibil evitarea supradimensionrii sau
subdimensionrii suprafeei de captare, o dimensionare optim pentru lunile de iarn implic o
supradimensionare pentru lunile de var i invers.

Dimensionarea colectorilor solari electrici:


Daca consideram ca o familie ar consuma intre 2 si 4 kWh/zi si alegem un colector
fotovoltaic cu urmatoarele caracteristici:

Numarul colectorilor fotovoltaici ales este intre 3 si 4, pentru un consum intre 2 si 4


kWh/zi. Investitia fiind foarte mare, cu supradimensionari pe perioada de vara si
subdimensionare, pe perioada de iarna, avand recuperarea investitiei intr-un numar mare de
ani.

S-ar putea să vă placă și