Documente Academic
Documente Profesional
Documente Cultură
Coninutul cursului
3 Armarea intern a elementelor de construcii cu produse din CPAF
3.1 Materiale compozite folosite ca materiale pentru armare existente pe piaa construciilor 3.2 Standarde de calcul 3.3 Lucrarea 3
fibre de sticla si fibre de carbon, in tabel fiind prezentate caracteristicile fibrelor de sticla marca ASLAN 100
armarea betonului (suprafaa lor are o amprenta cu nisip cuaros pentru o buna aderen cu betonul).
nglobate n raini polimerice. Compozitia este de 80% din greutate fibre de sticla i 20% rain epoxidic.
pultrudere
vinilesterica, avand o rezistenta la intindere de aproximativ 1596 MPa i un modul de elasticitate de 111,1 GPa
Comparatie bare din otel vs. bare din inox vs. bare din CPAFS
Studii de caz
Studii de caz
Studii de caz
Studii de caz
Pre-stressing tendons
Studii de caz
Studii de caz
Studii de caz
Studii de caz
Fort Manoel in Valletta built by the "Knights of Malta 1723 Restoration works - Malta
Studii de caz
Studii de caz
Studii de caz
Studii de caz
Studii de caz
Studii de caz
Studii de caz
Protejarea zidariei (zona de langa rost) impotriva murdaririi accidentale cu adeziv epoxidic folosind banda de hartie autoadeziva
Montarea barelor in sliturile preformate, metoada este cunoscuta sub denumirea de NSM (near surface mounted)
Tumialan, G., P.C. Huang, A. Nanni, and P. Silva, "Strengthening of Masonry Walls with Structural Repointing," Non-Metallic Reinforcement for Concrete Structures FRPRCS-5, Cambridge, July 16-18, 2001.
Zidarie neconfinata
Tumialan, G., P.C. Huang, A. Nanni, and P. Silva, "Strengthening of Masonry Walls with Structural Repointing," Non-Metallic Reinforcement for Concrete Structures FRPRCS-5, Cambridge, July 16-18, 2001.
Tumialan, G., P.C. Huang, A. Nanni, and P. Silva, "Strengthening of Masonry Walls with Structural Repointing," Non-Metallic Reinforcement for Concrete Structures FRPRCS-5, Cambridge, July 16-18, 2001.
Zona neconsolidata
Tabliere poduri
Studii de caz
Memorial Sloan Kettering Hospital - New York City - 10th floor 2-way slabs
Studii de caz
Memorial Sloan Kettering Hospital - New York City 10th floor 2-way slabs
Concrete Columns With Internal Bars Made Of Glass Fibers Can Make A Building Sturdier ScienceDaily (July 27, 2009) Conventional means of internal reinforcement for concrete member in buildings involve steel bars. Yet for structures that function in harsh environments like coastal regions, or for structures that support sensitive equipment, such as magnetic resonance imaging units; the use of fiber reinforced polymer (FRP) is emerging as a valuable option, due to its natural resistance to corrosion, its high strength, light weight, transparency to electrical and magnetic fields and ease of manufacturing and installment.
Sursa: http://www.sciencedaily.com/releases/2009/07/090714165056.htm
Testele de durabilitate
Agitator
Regulator termic
According to the durability test programme presented, the immersion trials on a series of 216 curved samples have been initiated.
With sealed ends With sealed ends With sealed ends With sealed ends
100 days 200 days 100 days 200 days 100 days 200 days 100 days 200 days
12 12 24 24 24 24 48 48
Testele de aderenta
Testele de aderenta
CONCRETE GRADE: C18/22.5 (according to the Romanian regulation NE012-99) CEMENT TYPE: IIA32.5 - 410 kg/cm AGGREGATE: 0 3 (sand) - 640 Kg/cm 3 7 (gravel) - 600 Kg/cm 7 16 (gravel) - 425 Kg/cm WATER: - 415 Kg/cm W/C RATIO: - 0,52
Testele de aderenta
F (N) 3500 3000 2500
max
Force [N]
F (N)
0. 1 5
1.5
2.5
Displacement [mm]
CONCRETE GRADE: C18/22.5 (according to the Romanian regulation NE012-99) CEMENT TYPE: IIA32.5 - 410 kg/cm AGGREGATE: 0 3 (sand) - 640 Kg/cm 3 7 (gravel) - 600 Kg/cm 7 16 (gravel) - 425 Kg/cm WATER: - 415 Kg/cm W/C RATIO: - 0,52
Moduri de cedare
AEF
Standarde in vigoare si proiectare structurilor din beton armate cu bare din CPAF (compozite polimerice armate cu fibre)
1. CNR-DT 203/2006 (2007), Guide for Design and Construction of Concrete Structures Reinforced with Fiber-Reinforced Polymer Bars, National Research Council Advisory Committee on Technical Recommendations for Construction, Rome, Italy. 2. ** fib Task Group 9.3, bulletin 40 (2007), FRP reinforcement in RC structures, International Federation of Structural Concrete, Lausanne. 3. ACI 440.1R-06 (2006), Guide for the Design and Construction of Concrete Reinforced with FRP bars, American Concrete Institute Committee, USA. 4. CAN/CSA-S806-02 A National Standard of Canada (2004), Design and Construction of Building Components with Fibre-Reinforced Polymers, Canadian Standards Association, Mississauga, Ontario, Canada.
Lucrarea 3
1. n diagrama de mai jos este prezentat testarea la ntindere a unei bare din compozite polimerice armate cu fibre de sticl. Determinai modulul de elasticitate i deformaia ultim a barei din CPAFS.
Bara cu diametrul de 8 mm
1200.00 1000.00
800.00
200.00
Lucrarea 3
Lucrarea 3
Site-uri utile cu informatii despre armare elementelor cu bare compozite, grile polimerice etc http://www.hughesbros.com http://www.schoeck-combar.com http://tillco.com/ http://www.tensarcorp.com