Documente Academic
Documente Profesional
Documente Cultură
Curs NR 1+fizica PDF
Curs NR 1+fizica PDF
FIZICA CONSTRUCIILOR
Curs nr. 1
Universitatea Politehnica din Timisoara
Fizica constructiilor - Constructii II
FIZICA CONSTRUCIILOR
FIZICA CONSTRUCIILOR
DOMENIUL ACOPERIT CONINE 3 SUBDOMENII
FIZICA CONSTRUCIILOR
2. ACUSTICA CLDIRILOR
FIZICA CONSTRUCIILOR
DOMENIUL ACOPERIT CONINE 3 SUBDOMENII
3. ILUMINATUL
DIRECIILE SPECIFICE:
- ILUMINATUL NATURAL
- ILUMINATUL ARTIFICIAL
- IMPACTUL ILUMINATULUI ASUPRA CONSUMULUI
TOTAL DE ENERGIE
EVOLUIA EFICIENEI
ENERGETICE N CONSTRUCII
1973 - 1983
1997 - 2009
1983 - 1997
STAS 6472 2 83 Building Physics. HYGROTHERMICS. External climatic parameters.
STAS 6472 3 89 Building Physics. THERMOTECHNICS. Thermotechnics calculus of
building structural elements.
STAS 6472 4 89 Building Physics. HEAT ENGINEERINGS. Response of structural
elements to water vapour diffusion. Calculation specifications.
STAS 6472 6 88 Building Physics. Thermotechnic design of structural elements with
thermal bridges.
STAS 6472 7 85 Building Physics. Thermotechnics. Calculus of air permeability of
building materials and components.
STAS 6472 10 85 Building Physics. Thermotechnics. Thermal transfer at floor contact.
Classification and determination method.
STAS 6472 11 85 Building Physics. Thermotechnics. Determination of air permeability of
building materials and components.
R0 Ri R Re
Ro Rezistena total la transfer termic [m2K/W];
Ri Rezistena la transfer termic pe suprafaa interioar [m2K/W];
Re Rezistena la transfer termic pe suprafaa exterioar [m2K/W];
R - Rezistena la transfer termic a elementului [m2K/W]
DETERMINAREA REZISTENEI LA
TRANSFER TERMIC PN N 1989
R0
R oc R 0 nec
m
Ro Rezistena total la transfer termic [m2K/W];
Roc Rezistena la transfer termic innd cont de masivitatea elementuli [m2K/W];
m masivitatea elementului funcie de ineria materialului;
Ro nec Rezistena minim la transfer termic [m2K/W].
VERIFICATION OF CONDENSE
APPEARANCE ON THE INTERIOR SURFACE
Tsi r
Tsi Temperatura suprafeei interioare [C];
r Temperatura punctului de rou [C].
Wef Wadmis
1950 1961 - - - - - - -
1985 1987 STAS 6472/3 84 0.76 0.87 0.56 0.76 0.87 0.56
1988 1989 STAS 6472/3 84 0.76 0.87 0.56 0.76 0.87 0.56
1990 1997 STAS 6472/3 89 1.00 1.24 0.67 1.00 1.24 0.67
1988 1989 STAS 6472/3 84 0.76 0.87 0.56 0.76 0.87 0.56
1990 1997 STAS 6472/3 89 1.00 1.24 0.67 1.00 1.24 0.67
AAC
5 5 5
25 cm 37 cm 30 cm 5 12 9
27 cm
E F G
reinforced reinforced
AAC concrete
concrete
reinforced
concrete
mineral AAC
wool
5 5 5 5
6 8 12 30 cm 5 12 12
27 cm 30 cm
Rezistena la transfer termic 0.68 0.57 0.54 0.57 0.97 0.93 0.67
R0,ef [m2K/W]
R0,ef / R0,nec 0.57 0.48 0.45 0.48 0.81 0.77 0.56
5 5
35 cm 15 30 2 8 7 12
45 cm 30 cm
d e f
reinforced AAC
concrete
AAC reinforced
masonry mineral concrete
wool
45 cm 7 8 12 20 15
27 cm 35 cm
ELEMENT Rm[m2K/W]
PN LA 01. 01. 1998 DUP 01. 01. 1998 /
RECOMANDAT
Lighting, 14%
Lighting
Gas, 10%
Gas
Heating, 55% Hot water
Hot water,
Heating
21%
2. C107/2 - 1997 Normativ pentru calculul coeficientului global de izolare termic la cldiri cu alt
destinaie dect cele de locuit
3. C107/3 - 1997 Normativ privind calculul termotehnica al elementelor de constructie ale cladirilor
4. C107/4 - 1997 Ghid pentru calculul performantelor termotehnice ale cladirilor de clocuit
5. C107/5 - 1997 Normativ privind calculul termotehnic al elementelor de constructie in contact cu solul
6. NP 048- 2000 Normativ pentru expertizarea termica si energetica acladirilor existente si a instalatiilor
de incalzire si preparare a apei calde de consum aferente acestora
7. NP 047- 2000 Normativ pentru realizarea auditului energetic al caldirilor existentesi al instalatiilor de
incalzire si preparare a apei calde de consum aferente acestora
8. NP 049- 2000 Normativ pentru elaborarea si acordarea certificatului energetic al cladirilor existente
9. GP 058 - 2000 Ghid privind optimizarea nivelului de protectie termica la cladirile de locuit
10. GP 015 - 2000 Ghid pentru expertiazarea si adoptarea solutiilor de imbunatatire a protectiei termice si
acustice la cladiri existente unifamniliale sau cu numar redus de apartamente
22. SC 007 - 2002 Solutii cadru pentru reabilitarea termo-higro-energetica a anvelopei cladirilor
de locuit existente
23. C107/0 - 2002 Normativ pentru proiectarea si executia lucrarilor de izolatii termice la cladiri
24. C107/7 - 2002 Normativ pentru proiectarea stabilitatii termice a elementelor de inchidere ale
cladirilor,
25. C107/6 - 2002 Normativ general privind calculul transferului de masa (umiditate) prin
elementele de constructie
26. C107/7 - 2002 Normativ pentru proiectarea la stabilitate termica a elementelor de inchidere
ale cladirilor
PRESCRIPII EUROPENE
NORMATIVE I STANDARDE -
REVIZUITE
NORMATIVE I STANDARDE
ROMANETI
1997 - 2006
ROMANIAN CODES
30
24
25
20
15
10
10
7
5
0
1973 - 1983 1983 - 1997 1997 - 2006
reinforced
Tip perete exteror Panou prefabricat 27 cm concrete
- Beton armat
- BCA AAC
- Beton armat
5 5
5 12 9
SECTIUNE ORIZONTALA
1
C Logia Logia
27
27
27
27
s=3.28 mp s=3.28 mp
hp=90 hp=90 hp=90 hp=90 hp=90 hp=90 h p=90
1.20
1.20
5 5 5 5
27 2.73 27 3.46 14 1.28 7 1.50 14 2.26 14 1.50 7 1.28 14 3.46 27 2.73 27
80 25
2.10
27
27
10
10
hp=90 hp=90
2.75
2.75
2.10
2.10
80
80
Baia Bucataria Bucataria Baia
s=4.12 mp s=4.57 mp s=4.57 mp s=4.12 mp
4.87
4.66
4.66
Dormitor
s=9.90 mp
3.46
3.46
Dormitor Camera de zi Camera de zi
s=9.90 mp s=16.07 mp s=16.07 mp
76
76
80 1.26 80 80 1.26 80
2.10 2.10 2.10 2.10
2.10
2.10
90
90
1.15
1.15
Hol Hol
2.10
90
90
2.10
s=3.47 mp s=3.47 mp
10 24 20
10 24 20
10 10
10 10
10.00
B
14
14
14
14
14
14
Hol Hol
s=4.73 mp s=4.73 mp
2.10
2.10
1.15
1.15
90
90
2.10
2.10
90
90
80 1.26 80 80 1.26 80
2 2.10 2.10 2.10 2.10 2
76
s=16.07 mp
3.46
3.46
5 5
27 2.86 14 3.46 14 1.28 7 1.50 14 2.26 14 1.50 75 1.28 5 14 3.46 14 2.86 27
4.66
4.87
Baia Baia
s=4.12 mp s=4.12 mp
2.10
2.10
80
80
4.66
38 1.50
Bucataria
2.75
2.75
hp=90 2.10 hp=90
Bucataria s=4.57 mp
10
10
s=4.57 mp
27
27
Logia Logia
1.20
1.20
s=3.28 mp s=3.28 mp
hp=90 hp=90 hp=90 hp=90 hp=90 hp=90
A
5
27
27
27
27
13
5 5 5 5
13 3.06 3.60 3.00 2.40 3.00 3.60 3.07 13
21.92
1 2 3 4 5 6 7 8
1
R 'm
[m2] [m2K/W] [m2K/W] - [W/K] [W/m3K]
REABILITAREA CMINULUI C 20
PREZENTARE GENERAL
- SISTEM ORIZONTAL:
CMINUL STUDENESC C 20
SECIUNE ORIZONTAL
4 5 6 7 8 9 10 11 12 12' 13
S=62,78mp
SALA DE LECTUR +1,44 +1,44 mozaic
A ETAJ 1
S=62,78mp
mozaic
CAMERA 110 B CAMERA 110 A CAMERA 109 B CAMERA 109 A CAMERA 108 B CAMERA 108 A CAMERA 107 B CAMERA 107 A CAMERA 106 B CAMERA 106 A
S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp
covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC
MAGAZIE MAGAZIE
+2,88 +2,88
S=2,20mp S=2,20mp
mozaic mozaic
HOL, WC, DUS 110 HOL, WC, DUS 109 HOL, WC, DUS 108 HOL, WC, DUS 107 HOL, WC, DUS 106
HOL S=10,00mp S=10,00mp S=10,00mp S=10,00mp S=10,00mp
4,67mp mozaic mozaic mozaic mozaic mozaic
ozaic
C
CULOAR ETAJ I
S=108,18mp
mozaic
B
HOL,WC,DUS100
S=5,25mp
mozaic HOL, WC, DUS 101 HOL, WC, DUS 102 HOL, WC, DUS 103 HOL, WC, DUS 104 HOL, WC, DUS 105
S=10,00mp S=10,00mp S=10,00mp S=10,00mp S=10,00mp
mozaic mozaic mozaic mozaic mozaic HOL+WC+GHENA
S= 8,00 mp
mozaic
CAMERA 100 CAMERA 101 B CAMERA 101 A CAMERA 102 B CAMERA 102 A CAMERA 103 B CAMERA 103 A CAMERA 104 B CAMERA 104 A CAMERA 105 B CAMERA 105 A SPALATORIE
S=20,57mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp S=20,90mp (FUMOAR)
beton covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC covor PVC S=17,80 mp
mozaic
1 2 3 4 5 6 7 8 9 10 11 12 13
CMINUL STUDENESC C 20
ALCTUIREA ARHITECTURAL FUNCIONAL A UNUI APARTMENT
4 5 6
4.20 4.20
2.40 1.80 2.40
1.30 1.30
p=90 p=90
-2 CAMERE
- 1 HOL (2 LAVOARE)
ROOM ROOM
S=20,90mp S=20,90mp - 1 CAMER DE DU
- 1 WC SERVICIU
.15 2.10 .08 .10 .90 .88 .15 .88 .90 .10 .07 2.10 .15
2.10 2.10
.55
.23 .55
.23 .08
2.10
.80
.80
Fizica constructiilor - Constructii II
- EXPERTIZA STRUCTURAL
- IZOLAREA TERMIC
- Rezisten mic la transfer termic ~ 0.8 [m2K/W]
de pe direcia NV
- SISTEMUL DE NCLZIRE
- nclzirea a fost asigurat de sistemul centralizat de la nivelul oraului
Fizica constructiilor - Constructii II
- INTERVENII STRUCTURALE
1
30
15
15
15
15
30 645 15
- NOUL PLANEU
1 PROPUS ARE GRINZI
1
20
DE BETON ARMAT
PENTRU PRELUAREA
Beam Ge 1 25x25
Beam Ge 1 25x25
Beam Ge 1 25x25
Beam Ge 1 25x25
NCRCRILOR
VERTICALE
CONCENTRATE
ADUSE DE
1 1
405
ECHIPAMENTELE DIN
CENTRALA TERMIC
4
2 3
91.5 25 129 25 129 25 129 25 66.5
2
15
15
15
15
15
Fizica constructiilor - Constructii II
Section 1-1
FIRST STOREY
+3.05 5 4 5 5 5
12
25
15
10
5
2
5 5 5
GROUND LEVEL
30 645 15
1. TIPURI DE ELEMENTE
1. TIPURI DE ELEMENTE
Single-wing windows
A B C D E F G H I J
G
A B C D E F G H I J
A B C D E F G H I J
TMPLRIA EXISTENT
- a fost complet nlocuit cu ferestre cu rame de PVC i geam termoizolant.
CENTRALA TERMIC
- a fost propus o central termic local pe gaz,
- schimbarea radiatoarelor i conductelor de distribuie
- Conductele de distribuie propuse se vor executa din polipropilen de nalt densitate,
preizolate dispuse la subsolul cldirii.
Fizica constructiilor - Constructii II
A B C D E F G H I J
80 121 166 217 277 347 433 544 700
AP CALD 54 [KWh/m2an]
C
A B C D E F G H I J
A B C D E F G H I J
105 164 229 303 389 490 615 775 1000
Fizica constructiilor - Constructii II
Faada SV
REABILITAREA TERMIC
FAADA SE
Fizica constructiilor - Constructii II
REABILITAREA INTERIOAR
Heating, 5.06
Ventilation, 1.27
Sanitary, 10.60
160
Heating consumption [GCal]
134.1
140
120 101.5
100 91.1 89.7 91
76.5 82.4 2004/2005
75.4
80
2006/2007
60
40
20
0
decembre january february march
Months
Fizica constructiilor - Constructii II
CONCLUZII
Dup reabilitare reducerea energiei totale consumate este de 50%. Reducerea este datorat
dublrii rezistenei la transfer termic pe cldire i reducerii pierderilor de pe coloanele de
distribuie. Nu este de neglijat faptul c prin poziionarea n cldire a centralei termice pierderile de
cldur de la punctul de furnizare la consumator au fost eliminate.
Reducerea important a consumului de energie pentru prepararea apei calde de consum este
datorat eficienei centralei termice i randamentului crescut al acesteia.
Lund n considerare costul total privind reabilitarea termic care este de aproximativ 110.000
Euro i economia de 2100 Euro/lun pentu nclzire i ap cald de consum, valoarea investiiei
pentru reabilitarea termic se amortizeaz n aproximativ 6 ani.
Fizica constructiilor - Constructii II
- 72. 000 m2
- 3 ETAJE
- PISCIN
- MULTIPLEX CINEMA
- KIDS LAND
- ~ 3.000 t ARMTURI I OEL STRUCTURAL - FOOD COURT
- ~ 80.000 m3 BETON
- 13.847 m2 VAT MINERAL 5 cm grosime + PANOURI SANDWICH 6 cm
- 18.500 m2 POLISTIREN 10 cm grosime
- 4.200 m2 FERESTRE DUBLE I UI TERMOIZOLATE
CORP D
CORP E
CORP C
CORP N
IZOLAII
TERMICE I
HIDROFUGE
SISTEMUL DE
IZOLARE
TERMIC LA
FAAD
DETERMINAREA REZISTENEI
LA TRANSFER TERMIC
R Rsi Rs Ra R se
R Rezistena total la transfer termic [m2K/W];
Rsi Rezistena la transfer termic pe suprafaa interioar [m2K/W];
Rse Rezistena la transfer termic pe suprafaa exterioar [m2K/W];
1
U [W/(m2K)]
R
U '
1 1
l
R' R A A
n care :
- R este rezistena termic specific unidirecional aferent ariei A;
- l este lungimea punilor liniare de acelai fel, din cadrul suprafeei A.
R' r R [W/(m2K)]
1
r
R [ l ]
1
A
DIMENSIONAREA TERMIC A
ELEMENTELOR DE NCHIDERE
Condiii igienico - sanitare
Rezistena termic necesar din considerente igienico-sanitare pentru elemente care separ
spaiul interior nclzit de mediul exterior, se calculeaz cu relaia :
Ti Te
R '
[m2K/W]
i Ti max
nec
n care :
-Ti max diferena maxim de temperatur, admis ntre temperatura interioar i temperatura medie a
suprafeei interioare Ti max = Ti - Tsim, la elemente care separ spaiul interior nclzit de mediul
exterior.
Valorile Ti max sunt prezentate n funcie de destinaia cldirii i de tipul elementului de
construcie;
Te -temperatura exterioar convenional de calcul. Valoarea Te se introduce cu semnul algebric
fiind considerat funcie de zonarea teritoriului Romniei;
- Ti - temperatura interioar convenional de calcul funcie de destinaia ncperilor.
DIMENSIONAREA TERMIC A
ELEMENTELOR DE NCHIDERE
Condiii igienico - sanitare
Ti max [K]
Grupa
Destinaia cldirii i (%)
cldirii
Perei Tavane Pardoseli
DIMENSIONAREA TERMIC A
ELEMENTELOR DE NCHIDERE
Condiia de economie de energie
Nr. Elementul de construcie Rmin [m2K/W]
crt.
CLDIRI PROIECTATE
pn la 1.01.1998 dup 1.01.1998
1. Perei exteriori (exclusiv suprafeele vitrate, inclusiv 1,20 1,40
pereii adiaceni rosturilor deschise)
2. Tmplrie exterioar 0,40 0,50
3. Planee peste ultimul nivel, sub terase sau poduri 2,00 3,00
4. Planee peste subsoluri nenclzite i pivnie 1,10 1,65
5. Perei adiaceni rosturilor nchise 0,90 1,10
6. Planee care delimiteaz cldirea la partea inferioar, 3,00 4,50
de exterior (la bowindouri, ganguri de trecere)
DIMENSIONAREA TERMIC A
ELEMENTELOR DE NCHIDERE
R R ' '
nec
Condiia de economie de energie
R R ' '
min
CONDENSUL IN CONSTRUCTII
VERIFICAREA APARIIEI CONDENSULUI PE SUPRAFAA INTERIOARA
Tsi r
Tsi Temperatura suprafetei interioare [C];
r Temperatura punctului de rou [C].
Wef Wadmis
(Ti Te )
Tsi Ti
i R
Tsi Temperatura suprafetei interioare [C];
Ti Temperatura interioar [C];
Te Temperatura exterioar [C];
i Coeficient superficial de transfer termic pe suprafaa interioar [C];
R Rezistena la transfer termic total [m2K/W];
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR - AN II
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR - AN II
FUNCIE DE
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR - AN II
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR - AN II
FUNCIE DE
pv ps
Curs 1
Universitatea Politehnica din Timisoara, Romania
FIZICA CONSTRUCTIILOR - AN II
(Ti Te ) R j
T j Ti
R
Tj Temperature la faa seciunii stratului j [C];
Ti Temperatura interioar [C];
i Coeficientul superficial pe suprafaa interioar [C];
R Rezistena total la transfer termic [m2K/W];
Curs 1
Universitatea Politehnica din Timisoara, Romania