Sunteți pe pagina 1din 2

Nota de utilizare:_________________________________

Ordin de Serviciu principal:_________________________


Ordin de serviciu secundar:_________________________
Tip Achizitie:____________________________________
Tip Notificare:___________________________________
FIA DE SOLUIE nr.141897446./25.02.2015.
Obiectiv LOCUINTA................................
Tip aviz ..nou-casnic captivi...............

Nr. inregistrare 141897446./Data05.02.2015


Aprobat,
SEF SSP DOINA GHENEA

Retiparire pentru schimbare data: ______________ Data intrare: ____________ Termen limita: ______________
ID GDS: _____ ID GDS aviz referinta.: _________ Descr. Sursa Alin: __________ Putere solicitata (kW): _21,8_____
Nume utilizator_CALIN CROITORU CRISTIAN DAN
Adresa: str DRUMUL REGIMENTULUI, nr 73-79_, telefon ___________, cod postal _______, localitatea BUCURESTI,
SECTOR 1_, CF ____________, nr. cad . __________, POD _______________
Tip:
Putere instalata (kW): 31,2 Putere maxima abs. (kW): 21,8 Tensiune: 400 V
Faze:
Note pentru biroul tehnic
Furnizare ceruta:
Tensiune racord:
Tensiune masura:
Termen solutie:
Furnizarea actuala corespunde Da/Nu
1) Date tehnice ale consumatorului: _ CALIN CROITORU CRISTIAN DAN
_
1.1 . putere instalata 31,2..kW
1.2 . putere maxim absorbita 21,8kW
1.3 . puterea celui mai mare receptor kW
2) Date despre instalatia existenta in zona :
2.1. Denumire statie de transformare 1
BANEASA - 110 /20kV
2.2. Capacitate statie de transformare 1 (Capacitate PT)____________________________________________
2.3. Sarcina maxima pe medie teniune statie de transformare 1(Sarcina maxima pe joasa tensiune a PT)
T1 ______ MVA R _____ S ______T ________ (A)
T2 ______ MVA R _____ S ______T ________ (A)
2.4. Denumire linie medie tensiune 1__LEA 20 kV JANDARMERIE
2.5. __
2.6. Denumirea plecarii pe j.t. pe care se face racordarea___________________________________________
2.7. Sectiunea minima a liniei de MT (a plecarii de j.t.), pana in punctul de racordare____________________
2.8. Incarcarea pe linia 1 T1 (plecarea jt pe care se face racordarea) R _____ S ______T ________ (A);
2 T2 R _____ S
______T ________ (A)
Situatie existenta Bransament trifazat subteran colectiv cu FDCP realizat conf ATR nr IERDC

04078/26.02.2007
3)

Solutia propusa :
4.1 Descriere solutie: Montare contor trifazat in FDCP 2-8 trifazat echipat cu intrerupatoare
automate diferentiale avand Ir=16A,cu inlocuirea unui intrerupator existent cu unul automat
cu protectie diferentiala avand Ir=35A ,amplasat pe support betonat pe domeniul public la
limita drum de servitute in exterior, realizat cu cablu jt 3x150+70mmp,racordat din CD a PT
3129.
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
_________________________________________________________________________________________________________

4.2 Parametrii tehnici ai instalatiei de racordare propuse:


- tip retea: subteran
- lungime _____________________________________________________________________________________________
sectiune _cablu jt ACYABY 3x150+70mmp__
4.3 Localizarea exacta a punctului de racordare:
- numarul stalpului (in cazul LEA) _________________________________________________________________________
- distanta fata de sursa __________________________________________________________________________________
- numarul de inventar al mijlocului fix din care se face racordarea PT3129 / 250 kVA__
- anul PIF _____________________________________________________________________________________________
- sursa de finantare ___FP/TR_____________________________________________________________________________
- lucrari de intarire a capacitatii in amonte de punctul de racordare: _______________________________________________
(inlocuire stalpi, marire sectiune etc)
_____________________________________________________________________________________________________
_____________________________________________________________________________________________________
valoare lucrari de intarire_____________________termenul posibil de realizare_____________________________________
5) Schema electrica monofilara a retelei existente si propuse:

6) Punctul de delimitare a instalaiilor este stabilit la nivelul de tensiune __0,40_ kV, la _borne iesire contor_ (elementul
fizic unde se face delimitarea); elementele menionate sunt n proprietatea _operatorului de retea_(dup caz, proprietar este
utilizatorul sau operatorul de reea).
7)Punctul de msurare este stabilit la nivelul de tensiune:0,4_kV,in FDCP/pe (capacitatile energetice).
Msurarea energiei electrice se realizeaz prin contor trifazat___ (cerintele tehnice minime pentru echipamentele de
masurare).
8) Cerine pentru proteciile i automatizrile la interfaa cu reeaua electric ______________________________
9) Alte cerine:
- de monitorizare i reglaj ______________________________________________________________________________
- interfeele sistemelor de monitorizare, comand, achiziie de date, msurare a energiei electrice, telecomunicaii _____
- pentru principalele echipamente de msurare, protecie, control i automatizare din instalaiile utilizatorului
___________________________________________________
10) Condiii specifice pentru racordare _Necesar depunere dosar instalatie de utilizare de catre un electrician

autorizat.____________________________________________
11)Datele nregistrate care necesit verificarea n timpul funcionrii _______________________________________
12) Cerine i condiii specifice pentru furnizarea de servicii tehnologice de sistem ctre operatorul de transport i de sistem sau
ctre operatorii de distribuie (daca este cazul) ______________________________________________________________;
13) Situatia juridica a terenului pe care se va amplasa instalatia de racordare propusa:____________________________

Verificat,
Sef Centru :Ing M.Carasol

Intocmit
Th V. Bulisache