S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.

2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4122/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 129+000 - 130+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 129+200 85 88 89 83 85 86 84 87 85 83 85 88
MEDIA CITIRILOR 87 85 85 85
Sectiunea 2- KM 129+210 80 82 83 82 84 87 85 81 83 86 88 87
MEDIA CITIRILOR 82 84 83 87
Sectiunea 3- KM 129+220 82 85 87 84 85 89 82 86 88 84 87 82
MEDIA CITIRILOR 85 86 85 84
Sectiunea 4- KM 129+230 81 83 85 86 88 87 80 84 86 83 84 85
MEDIA CITIRILOR 83 87 83 84
Sectiunea 5- KM 129+240 86 88 89 82 83 81 85 87 84 82 86 84
MEDIA CITIRILOR 88 82 85 84
MEDIA VALORILOR 85 85 84 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 85 85 84 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4122/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 129+000 - 130+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 129+500 88 90 91 83 84 85 82 85 86 85 89 87
MEDIA CITIRILOR 90 84 84 87
Sectiunea 2- KM 129+510 87 90 91 87 89 89 82 83 85 86 88 89
MEDIA CITIRILOR 89 88 83 88
Sectiunea 3- KM 129+520 82 83 85 81 84 85 80 82 84 83 86 88
MEDIA CITIRILOR 83 83 82 86
Sectiunea 4- KM 129+530 82 84 85 83 86 85 80 82 81 83 80 81
MEDIA CITIRILOR 84 85 81 81
Sectiunea 5- KM 129+540 79 81 83 82 84 85 84 86 87 85 84 82
MEDIA CITIRILOR 81 84 86 84
MEDIA VALORILOR 85 85 83 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 85 85 83 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4122/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 129+000 - 130+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 129+800 87 88 89 86 87 88 84 87 86 84 86 87
MEDIA CITIRILOR 88 87 86 86
Sectiunea 2- KM 129+810 82 85 87 84 85 87 88 89 87 86 88 90
MEDIA CITIRILOR 85 85 88 88
Sectiunea 3- KM 129+820 85 89 87 83 84 87 83 87 88 84 88 89
MEDIA CITIRILOR 87 85 86 87
Sectiunea 4- KM 129+830 87 91 89 86 88 89 84 82 85 86 87 86
MEDIA CITIRILOR 89 88 84 86
Sectiunea 5- KM 129+840 84 88 89 82 84 85 83 85 84 87 88 87
MEDIA CITIRILOR 87 84 84 87
MEDIA VALORILOR 87 86 85 87
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 86 85 87
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4123/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 130+000 - 131+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 130+200 82 86 85 80 85 81 84 86 88 82 87 84
MEDIA CITIRILOR 84 82 86 84
Sectiunea 2- KM 130+210 87 86 85 83 88 85 89 86 87 83 86 89
MEDIA CITIRILOR 86 85 87 86
Sectiunea 3- KM 130+220 88 91 89 87 89 86 88 89 90 91 89 90
MEDIA CITIRILOR 89 87 89 90
Sectiunea 4- KM 130+230 87 90 89 89 92 90 90 92 91 89 87 90
MEDIA CITIRILOR 89 90 91 89
Sectiunea 5- KM 130+240 86 89 88 89 92 95 90 94 91 93 95 94
MEDIA CITIRILOR 88 92 92 94
MEDIA VALORILOR 87 87 89 89
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 87 89 89
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4123/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 130+000 - 131+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 130+600 81 85 84 86 87 85 81 80 83 79 82 84
MEDIA CITIRILOR 83 86 81 82
Sectiunea 2- KM 130+610 80 82 84 82 84 83 80 84 86 84 85 87
MEDIA CITIRILOR 82 83 83 85
Sectiunea 3- KM 130+620 79 84 82 80 85 88 83 87 84 85 89 84
MEDIA CITIRILOR 82 84 85 86
Sectiunea 4- KM 130+630 82 86 83 81 84 85 80 84 86 82 88 87
MEDIA CITIRILOR 84 83 83 86
Sectiunea 5- KM 130+640 86 89 85 84 86 82 80 85 83 84 89 85
MEDIA CITIRILOR 87 84 83 86
MEDIA VALORILOR 83 84 83 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 83 84 83 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4123/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 130+000 - 131+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 130+900 84 86 80 81 84 86 88 90 86 89 92 90
MEDIA CITIRILOR 83 84 88 90
Sectiunea 2- KM 130+910 89 88 87 84 89 85 83 87 82 85 87 85
MEDIA CITIRILOR 88 86 84 86
Sectiunea 3- KM 130+920 90 88 92 91 89 87 88 92 90 89 88 90
MEDIA CITIRILOR 90 89 90 89
Sectiunea 4- KM 130+930 80 82 79 81 85 83 86 89 84 82 84 81
MEDIA CITIRILOR 80 83 86 82
Sectiunea 5- KM 130+940 83 85 80 82 87 88 84 86 82 85 88 83
MEDIA CITIRILOR 83 86 84 85
MEDIA VALORILOR 85 85 86 87
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 85 85 86 87
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4124/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 131+000 - 132+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 131+250 86 91 89 91 92 90 89 90 92 88 90 92
MEDIA CITIRILOR 89 91 90 90
Sectiunea 2- KM 131+260 89 87 90 89 87 92 90 91 94 93 95 92
MEDIA CITIRILOR 89 89 92 93
Sectiunea 3- KM 131+270 82 84 82 85 87 89 83 83 84 85 81 83
MEDIA CITIRILOR 83 87 83 83
Sectiunea 4- KM 131+280 87 84 86 89 89 87 85 83 86 82 82 83
MEDIA CITIRILOR 86 88 85 82
Sectiunea 5- KM 131+290 89 91 87 90 88 87 84 86 83 85 84 82
MEDIA CITIRILOR 89 88 84 84
MEDIA VALORILOR 87 89 87 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 89 87 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4124/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 131+000 - 132+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 131+500 90 92 88 93 88 89 84 88 85 86 84 85
MEDIA CITIRILOR 90 90 86 85
Sectiunea 2- KM 131+510 83 85 82 85 87 89 83 83 84 85 81 83
MEDIA CITIRILOR 83 87 83 83
Sectiunea 3- KM 131+520 87 84 86 89 89 87 85 83 86 82 82 83
MEDIA CITIRILOR 86 88 85 82
Sectiunea 4- KM 131+530 89 91 87 90 88 87 84 86 83 85 84 82
MEDIA CITIRILOR 89 88 84 84
Sectiunea 5- KM 131+540 87 85 82 82 87 89 83 88 84 82 84 81
MEDIA CITIRILOR 85 86 85 82
MEDIA VALORILOR 87 88 85 83
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 88 85 83
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4124/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 131+000 - 132+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 131+850 81 80 81 83 82 85 84 80 83 82 81 80
MEDIA CITIRILOR 81 83 82 81
Sectiunea 2- KM 131+860 88 89 84 85 89 84 85 82 86 85 82 84
MEDIA CITIRILOR 87 86 84 84
Sectiunea 3- KM 131+870 89 91 88 87 88 87 84 85 82 87 84 81
MEDIA CITIRILOR 89 87 84 84
Sectiunea 4- KM 131+880 81 85 83 88 86 89 85 83 84 86 83 84
MEDIA CITIRILOR 83 88 84 84
Sectiunea 5- KM 131+890 90 88 91 89 92 87 86 82 85 84 82 83
MEDIA CITIRILOR 90 89 84 83
MEDIA VALORILOR 86 87 84 83
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 87 84 83
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4125/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 132+000 - 133+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 132+150 92 95 90 88 91 87 89 88 86 88 92 90
MEDIA CITIRILOR 92 89 88 90
Sectiunea 2- KM 132+160 80 87 85 88 86 87 82 80 84 86 87 84
MEDIA CITIRILOR 84 87 82 86
Sectiunea 3- KM 132+170 80 82 83 85 83 84 86 86 88 82 84 81
MEDIA CITIRILOR 82 84 87 82
Sectiunea 4- KM 132+180 90 87 88 85 84 87 86 83 85 87 86 89
MEDIA CITIRILOR 88 85 85 87
Sectiunea 5- KM 132+190 81 83 85 82 88 84 88 85 82 84 85 87
MEDIA CITIRILOR 83 85 85 85
MEDIA VALORILOR 86 86 85 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 86 85 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4125/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 132+000 - 133+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 132+500 84 83 81 85 88 89 86 84 82 81 84 86
MEDIA CITIRILOR 83 87 84 84
Sectiunea 2- KM 132+510 85 82 84 84 87 86 82 85 81 80 83 82
MEDIA CITIRILOR 84 86 83 82
Sectiunea 3- KM 132+520 83 86 87 84 86 88 82 85 84 88 87 86
MEDIA CITIRILOR 85 86 84 87
Sectiunea 4- KM 132+530 83 85 84 83 85 88 86 85 87 85 87 88
MEDIA CITIRILOR 84 85 86 87
Sectiunea 5- KM 132+540 83 87 85 86 88 87 84 89 86 88 87 85
MEDIA CITIRILOR 85 87 86 87
MEDIA VALORILOR 84 86 85 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 84 86 85 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4125/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 132+000 - 133+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 132+700 82 85 80 84 83 85 81 83 80 84 87 81
MEDIA CITIRILOR 82 84 81 84
Sectiunea 2- KM 132+710 88 85 83 83 82 80 82 80 84 81 84 86
MEDIA CITIRILOR 85 82 82 84
Sectiunea 3- KM 132+720 80 84 82 85 87 81 79 82 84 80 84 81
MEDIA CITIRILOR 82 84 82 82
Sectiunea 4- KM 132+730 85 87 89 90 89 85 83 86 85 83 81 84
MEDIA CITIRILOR 87 88 85 83
Sectiunea 5- KM 132+740 88 91 95 83 85 84 87 90 88 89 88 86
MEDIA CITIRILOR 91 84 88 88
MEDIA VALORILOR 86 84 84 84
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 84 84 84
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4126/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 133+000 - 134+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 133+100 88 89 85 80 82 84 80 87 85 90 91 89
MEDIA CITIRILOR 87 82 84 90
Sectiunea 2- KM 133+110 80 83 81 85 82 86 89 87 87 84 82 86
MEDIA CITIRILOR 81 84 88 84
Sectiunea 3- KM 133+120 88 89 85 82 84 83 88 90 87 83 83 85
MEDIA CITIRILOR 87 83 88 84
Sectiunea 4- KM 133+130 84 87 86 89 89 85 90 91 88 84 85 85
MEDIA CITIRILOR 86 88 90 85
Sectiunea 5- KM 133+140 83 80 82 81 85 84 86 83 84 88 85 86
MEDIA CITIRILOR 82 83 84 86
MEDIA VALORILOR 85 84 87 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 85 84 87 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4126/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 133+000 - 134+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 133+400 82 83 81 85 87 84 83 82 85 87 84 86
MEDIA CITIRILOR 82 85 83 86
Sectiunea 2- KM 133+410 84 87 85 88 86 87 82 80 84 86 87 84
MEDIA CITIRILOR 85 87 82 86
Sectiunea 3- KM 133+420 90 87 88 85 86 83 82 81 84 87 82 85
MEDIA CITIRILOR 88 85 82 85
Sectiunea 4- KM 133+430 91 88 88 86 84 85 83 83 84 87 85 86
MEDIA CITIRILOR 89 85 83 86
Sectiunea 5- KM 133+440 89 90 87 84 83 86 87 84 85 83 81 86
MEDIA CITIRILOR 89 84 85 83
MEDIA VALORILOR 87 85 83 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 85 83 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4126/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 133+000 - 134+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 133+900 80 82 83 85 83 84 86 86 88 82 84 81
MEDIA CITIRILOR 82 84 87 82
Sectiunea 2- KM 133+910 90 87 88 85 84 87 86 83 85 87 86 89
MEDIA CITIRILOR 88 85 85 87
Sectiunea 3- KM 133+920 83 81 84 85 85 87 82 86 87 90 88 87
MEDIA CITIRILOR 83 86 85 88
Sectiunea 4- KM 133+930 84 86 83 87 85 87 89 87 88 89 90 87
MEDIA CITIRILOR 84 86 88 89
Sectiunea 5- KM 133+940 84 86 85 87 82 85 84 86 89 82 87 88
MEDIA CITIRILOR 85 85 86 86
MEDIA VALORILOR 84 85 86 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 84 85 86 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4127/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 134+000 - 135+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 134+200 86 89 88 89 92 95 90 94 91 93 95 94
MEDIA CITIRILOR 88 92 92 94
Sectiunea 2- KM 134+210 84 86 80 81 84 86 88 90 86 89 92 90
MEDIA CITIRILOR 83 84 88 90
Sectiunea 3- KM 134+220 89 88 87 84 89 85 83 87 82 85 87 85
MEDIA CITIRILOR 88 86 84 86
Sectiunea 4- KM 134+230 90 88 92 91 89 87 88 92 90 89 88 90
MEDIA CITIRILOR 90 89 90 89
Sectiunea 5- KM 134+240 83 85 80 82 87 88 84 86 82 85 88 83
MEDIA CITIRILOR 83 86 84 85
MEDIA VALORILOR 86 87 88 89
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 87 88 89
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4127/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 134+000 - 135+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 134+500 86 89 85 84 86 82 80 85 83 84 89 85
MEDIA CITIRILOR 87 84 83 86
Sectiunea 2- KM 134+510 82 86 83 81 84 85 80 84 86 82 88 87
MEDIA CITIRILOR 84 83 83 86
Sectiunea 3- KM 134+520 81 85 84 86 87 85 81 80 83 79 82 84
MEDIA CITIRILOR 83 86 81 82
Sectiunea 4- KM 134+530 87 90 89 89 92 90 90 92 91 89 87 90
MEDIA CITIRILOR 89 90 91 89
Sectiunea 5- KM 134+540 85 87 89 90 89 85 83 86 85 83 81 84
MEDIA CITIRILOR 87 88 85 83
MEDIA VALORILOR 86 86 85 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 86 85 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4127/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 134+000 - 135+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 134+800 82 84 82 85 87 89 83 83 84 85 81 83
MEDIA CITIRILOR 83 87 83 83
Sectiunea 2- KM 134+810 89 91 87 90 88 87 84 86 83 85 84 82
MEDIA CITIRILOR 89 88 84 84
Sectiunea 3- KM 134+820 83 85 82 85 87 89 83 83 84 85 81 83
MEDIA CITIRILOR 83 87 83 83
Sectiunea 4- KM 134+830 87 85 82 82 87 89 83 88 84 82 84 81
MEDIA CITIRILOR 85 86 85 82
Sectiunea 5- KM 134+840 89 91 88 87 88 87 84 85 82 87 84 81
MEDIA CITIRILOR 89 87 84 84
MEDIA VALORILOR 86 87 84 83
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 87 84 83
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4128/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 135+000 - 136+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 135+150 80 82 83 85 83 84 86 86 88 82 84 81
MEDIA CITIRILOR 82 84 87 82
Sectiunea 2- KM 135+160 90 87 88 85 84 87 86 83 85 87 86 89
MEDIA CITIRILOR 88 85 85 87
Sectiunea 3- KM 135+170 83 81 84 85 85 87 82 86 87 90 88 87
MEDIA CITIRILOR 83 86 85 88
Sectiunea 4- KM 135+180 84 86 83 87 85 87 89 87 88 89 90 87
MEDIA CITIRILOR 84 86 88 89
Sectiunea 5- KM 135+190 85 86 85 87 82 85 84 86 89 82 87 88
MEDIA CITIRILOR 85 85 86 86
MEDIA VALORILOR 84 85 86 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 84 85 86 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4128/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 135+000 - 136+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 135+500 82 83 81 85 87 84 83 82 85 87 84 86
MEDIA CITIRILOR 82 85 83 86
Sectiunea 2- KM 135+510 84 87 85 88 86 87 82 80 84 86 87 84
MEDIA CITIRILOR 85 87 82 86
Sectiunea 3- KM 135+520 90 87 88 85 86 83 82 81 84 87 82 85
MEDIA CITIRILOR 88 85 82 85
Sectiunea 4- KM 135+530 91 88 88 86 84 85 83 83 84 87 85 86
MEDIA CITIRILOR 89 85 83 86
Sectiunea 5- KM 135+540 89 90 87 84 83 86 87 84 85 83 81 86
MEDIA CITIRILOR 89 84 85 83
MEDIA VALORILOR 87 85 83 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 85 83 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4128/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 135+000 - 136+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 135+750 83 80 82 81 85 84 86 83 84 88 85 86
MEDIA CITIRILOR 82 83 84 86
Sectiunea 2- KM 135+760 84 87 86 89 89 85 90 91 88 84 85 85
MEDIA CITIRILOR 86 88 90 85
Sectiunea 3- KM 135+770 88 89 85 82 84 83 88 90 87 83 83 85
MEDIA CITIRILOR 87 83 88 84
Sectiunea 4- KM 135+780 80 83 81 85 82 86 89 87 87 84 82 86
MEDIA CITIRILOR 81 84 88 84
Sectiunea 5- KM 135+790 88 89 85 80 82 84 80 87 85 90 91 89
MEDIA CITIRILOR 87 82 84 90
MEDIA VALORILOR 85 84 87 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 85 84 87 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4129/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 136+000 - 137+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 136+100 82 80 81 84 83 85 84 83 85 81 80 79
MEDIA CITIRILOR 81 84 84 80
Sectiunea 2- KM 136+110 88 84 81 86 84 85 82 81 80 83 81 82
MEDIA CITIRILOR 84 85 81 82
Sectiunea 3- KM 136+120 79 82 80 81 83 84 80 84 86 88 87 86
MEDIA CITIRILOR 80 83 83 87
Sectiunea 4- KM 136+130 84 83 82 85 84 82 87 85 88 82 84 80
MEDIA CITIRILOR 83 84 87 82
Sectiunea 5- KM 136+140 85 87 86 86 81 84 83 85 84 82 86 85
MEDIA CITIRILOR 86 84 84 84
MEDIA VALORILOR 83 84 84 83
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 83 84 84 83
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4129/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 136+000 - 137+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 136+550 82 81 80 85 87 84 83 82 85 87 84 86
MEDIA CITIRILOR 81 85 83 86
Sectiunea 2- KM 136+560 86 91 89 91 92 90 89 90 92 88 90 92
MEDIA CITIRILOR 89 91 90 90
Sectiunea 3- KM 136+570 85 87 88 85 86 83 82 81 84 87 82 85
MEDIA CITIRILOR 87 85 82 85
Sectiunea 4- KM 136+580 81 83 85 82 88 84 88 85 82 84 85 87
MEDIA CITIRILOR 83 85 85 85
Sectiunea 5- KM 136+590 89 86 87 84 83 86 87 84 85 83 81 86
MEDIA CITIRILOR 87 84 85 83
MEDIA VALORILOR 85 86 85 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 85 86 85 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4129/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 136+000 - 137+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 136+900 82 81 83 81 85 84 86 83 84 88 85 86
MEDIA CITIRILOR 82 83 84 86
Sectiunea 2- KM 136+910 84 87 86 89 89 85 90 91 88 84 85 85
MEDIA CITIRILOR 86 88 90 85
Sectiunea 3- KM 136+920 88 84 85 82 84 83 88 90 87 83 83 85
MEDIA CITIRILOR 86 83 88 84
Sectiunea 4- KM 136+930 80 83 81 85 82 86 89 87 87 84 82 86
MEDIA CITIRILOR 81 84 88 84
Sectiunea 5- KM 136+940 88 87 85 80 82 84 80 87 85 90 91 89
MEDIA CITIRILOR 87 82 84 90
MEDIA VALORILOR 84 84 87 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 84 84 87 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/3
RAPORT DE INCERCARE
NR. 4130/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 137+000 - 138+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 137+200 82 86 85 80 85 81 84 86 88 82 87 84
MEDIA CITIRILOR 84 82 86 84
Sectiunea 2- KM 137+210 87 86 85 83 88 85 89 86 87 83 86 89
MEDIA CITIRILOR 86 85 87 86
Sectiunea 3- KM 137+220 88 91 89 87 89 86 88 89 90 91 89 85
MEDIA CITIRILOR 89 87 89 88
Sectiunea 4- KM 137+230 87 85 84 83 81 84 90 92 91 89 87 86
MEDIA CITIRILOR 85 83 91 87
Sectiunea 5- KM 137+240 86 89 88 89 92 95 90 94 91 89 88 87
MEDIA CITIRILOR 88 92 92 88
MEDIA VALORILOR 87 86 89 87
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 87 86 89 87
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 2/3
RAPORT DE INCERCARE
NR. 4130/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 137+000 - 138+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 2 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 137+500 81 85 84 86 87 85 81 80 83 79 82 84
MEDIA CITIRILOR 83 86 81 82
Sectiunea 2- KM 137+510 80 82 84 82 84 83 80 84 86 84 85 87
MEDIA CITIRILOR 82 83 83 85
Sectiunea 3- KM 137+520 79 84 82 80 85 88 83 87 84 85 89 84
MEDIA CITIRILOR 82 84 85 86
Sectiunea 4- KM 137+530 82 86 83 81 84 85 80 84 86 82 88 87
MEDIA CITIRILOR 84 83 83 86
Sectiunea 5- KM 137+540 86 89 85 84 86 82 80 85 83 84 89 85
MEDIA CITIRILOR 87 84 83 86
MEDIA VALORILOR 83 84 83 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 83 84 83 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin

S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015


Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 3/3
RAPORT DE INCERCARE
NR. 4130/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 137+000 - 138+000 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 137+800 84 86 80 81 84 86 88 90 86 89 92 90
MEDIA CITIRILOR 83 84 88 90
Sectiunea 2- KM 137+810 83 85 80 82 87 88 84 86 82 85 88 83
MEDIA CITIRILOR 83 86 84 85
Sectiunea 3- KM 137+820 82 84 82 85 87 89 83 83 84 85 81 83
MEDIA CITIRILOR 83 87 83 83
Sectiunea 4- KM 137+830 80 82 79 81 85 83 86 84 84 82 84 81
MEDIA CITIRILOR 80 83 85 82
Sectiunea 5- KM 137+840 83 85 80 82 87 88 84 81 82 85 88 83
MEDIA CITIRILOR 83 86 82 85
MEDIA VALORILOR 82 85 84 85
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 82 85 84 85
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin
S.C. CONSIM LABORATOR S.R.L. Autorizatie laborator grad II , nr. 3030/30.06.2015
Str. Barlea, Nr.5-13, Etaj 2, Sector 5 - Bucuresti Cod :CON-RI-LC-D-15
Tel. : (021)4247020 Fax :(021)4574914 Pag 1/1
RAPORT DE INCERCARE
NR. 4131/30.09.2017
MASURATORI CU RUGOZIMETRUL SRT
CLIENT: S.C. ROADMAX CONSTRUCT S.R.L.
ADRESA: Strada Nicolae Iorga Nr. 20, etaj 2, camera nr. 6, Constanta
Lucrari de straturi rutiere foarte subtiri turnate la rece in doua straturi executate pentru DRDP Constanta in anul 2017,
LUCRAREA: SDN Constanta - DN 3 Km 129+000 - Km 138+201
Data efectuarii determinarii : 27.09.2017 Temperatura atmosferica : 19 ᵒC Comanda nr. 3858/22.09.2017

STANGA DREAPTA
KM 138+000 - 138+201 Distanta de margine 1m Distanta de ax 0.5m Distanta de ax 0.5m Distanta de margine 1m
SECTOR 1 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3 CITIREA 1 CITIREA 2 CITIREA 3
Sectiunea 1- KM 138+100 92 95 90 88 91 87 89 88 86 88 92 90
MEDIA CITIRILOR 92 89 88 90
Sectiunea 2- KM 138+110 80 87 85 88 86 87 82 80 84 86 87 84
MEDIA CITIRILOR 84 87 82 86
Sectiunea 3- KM 138+120 80 82 83 85 83 84 86 86 88 82 84 81
MEDIA CITIRILOR 82 84 87 82
Sectiunea 4- KM 138+130 90 87 88 85 84 87 86 83 85 87 86 89
MEDIA CITIRILOR 88 85 85 87
Sectiunea 5- KM 138+140 81 83 85 82 88 84 88 85 82 84 85 87
MEDIA CITIRILOR 83 85 85 85
MEDIA VALORILOR 86 86 85 86
VALORI CORECTATE (COEFICIENT DE CORECTIE +0 SRT.)
VALORI 86 86 85 86
Valorile limita admisibile - Normativ AND 523/2003 Valori SRT ˃ 65 UNITATI SRT
Metoda de determinare : SR EN 13036- 4/2004; CON-PL-D-60
Temperatura atmosferica : 19 ᵒC
Temperatura imbracamintii rutiere : 21°C
Valoarea coeficientului de corectie pentru t <30°C = +0 SRT.
Urmare incercarilor efectuate nu sunt incertitudini cu privire la rezultatul acestora cauzate de: utilizarea aparaturii din dotare,vicii de procedura,modul de prelevare al probelor
Raportul de incercare emis este valabil numai pentru materialele supuse incercarilor.
Prezentul raport de incercare contine o pagina si s-a eliberat in vederea utilizarii pentru verificarea caracteristicilor fizico-mecanice.
Raportul de incercare nu poate fi multiplicat sau utilizat in alte scopuri fara aprobarea scrisa a laboratorului.
Declaram pe propria raspundere ca incercarile nu s-au efectuat sub presiune de nici o forma.
SEF LABORATOR SEF PROFIL
Ing. Stoica Silviu Tehn. Alexe Valentin