INTRODUCERE .......................................................................................................... 4
OPERARE ................................................................................................................... 9
Dezarmarea ........................................................................................................................ 12
Alte comenzi de operare .................................................................................................... 12
Izolarea zonelor ..................................................................................................................... 12
Afiarea strii sistemului ....................................................................................................... 13
Afiarea memoriei de alarm ................................................................................................ 13
Funcia "Chime" On/Off ......................................................................................................... 13
Programarea/Modificarea codurilor de utilizator .................................................................. 14
Oprirea apelrii telefonice ..................................................................................................... 15
INTRODUCERE
CARACTERISTICI
GENERALE
primele 9 evenimente tip alarm, care au avut loc dup ultima armare, sunt
afiabile pe tastatur;
7 numere de telefon programabile pentru transmisia unui mesaj pentru
modelul Cerber C41V1, respectiv a 4 mesaje pentru modelul Cerber
C41V4;
durata mesajelor i numrul de apeluri sunt programabile;
monitorizarea strii sistemului, a bateriei i a tensiunii de reea;
memorie EEPROM care pstreaz configuraia programat, n cazul
ntreruperii alimentrii cu tensiune;
pn la 4 tastaturi pot fi cuplate pe o unitate central, prin legare pe 4 fire;
opiune de protecie a tastaturii la sabotaj, prin microntreruptor;
LED-uri individuale de stare a zonelor cu indicarea strii de alarm;
LED-uri de stare a sistemului: PREGTIT, SISTEM, ARMAT.
SPECIFICAII
TEHNICE
Alimentare
acumulator: 12V/4Ah;
Intrri
Ieiri
CENTRALEI
MONTAREA
TASTATURII
CABLAREA
NOT: Se realizeaz toate conexiunile nainte alimentarea centralei de
la baterie sau de la reeaua de curent alternativ 220Vca.
Cablarea se va face conform uneia dintre diagramele ce urmeaz, n funcie
de modelul Cerber C41V1 sau Cerber C41V4.
F2
F1
AUX
1,6A
SIREN
1,6A
PLAY RECORD
MIC
DIF
LINIE
TELEFONIC
APARAT
TELEFONIC
IESIRE
SIR E NA
M AX 1A
R E S P E C TAT I
P O L A R ITAT E A
+
ROU
NEGRU
REZISTEN
EOL 2K2
REZISTEN
EOL 2K2
GRN
YEL
MASA
AC UM U L AT O R
12V/4Ah
+12VCC
UR
TAT
TAS
A
CHEIE CU
REVENIRE
NC
REZISTEN
EOL 2K2
BUSY
RECORD
F2
F1
AUX
1,6A
SIREN
1,6A
M1 M2 M3 M4
R EC
MIC
DIF
LINIE
TELEFONIC
APARAT
TELEFONIC
+
ROU
NEGRU
IESIRE
SIRE NA
M AX 1A
R E S P E C TAT I
P O L A R ITAT E A
12V/4Ah
REZISTEN
EOL 2K2
GRN
YEL
AC UM U L AT O R
REZISTEN
EOL 2K2
MASA
+12VCC
UR
TAT
TAS
A
CHEIE CU
REVENIRE
NC
REZISTEN
EOL 2K2
BORNELE
DE CONEXIUNI
PUNEREA
N FUNCIUNE
OPERARE
CODURILE
DE OPERARE
CODUL
DE INSTALATOR
ARMAREA
[COD
DE UTILIZATOR]
ALTE
MODURI DE ARMARE
INSTANTANEE)
DE UTILIZATOR]
DE UTILIZATOR]
DEZARMAREA
[COD
DE UTILIZATOR]
ALTE
COMENZI DE OPERARE
IZOLAREA
ZONELOR
DE UTILIZATOR]
12
STRII SISTEMULUI
[*] [4]
Sistemul de alarm supravegheaz permanent o serie de condiii impuse
pentru buna sa funcionare. Cnd una din aceste condiii nu este
respectat, LED-ul SISTEM se va aprinde.
Pentru a afia starea acestor condiii se tasteaz [*] [4]. Afiarea acestor
condiii se face pe LED-urile de zone, dup cum urmeaz:
LED Zona 1
Baterie descrcat: dac bateria este deconectat sau
are tensiunea mic, atunci acest LED este aprins. LED-ul se va stinge la 8s
dup restabilirea circuitului bateriei.
LED Zona 2
Tensiune de 220V lips: dac tensiunea de la reeaua de
220Vac se ntrerupe, transformatorul este ars sau sigurana de pe circuitul
de reea este ars, atunci acest LED este aprins. LED-ul se va stinge
imediat la restabilirea circuitului de alimentare de la reea.
Ieirea din acest mod de afiare se face prin apsarea tastei [#].
AFISAREA
MEMORIEI DE ALARM
[*] [5]
Alarmele produse n decursul ultimei armri sunt memorate. Pentru a afia
zonele care au intrat n alarm se tasteaz [*] [5].
LED-ul SISTEM va clipi, precum i LED-urile zonelor care au intrat n
alarm. Pentru a vizualiza primele 9 zone alarmate n timpul ultimei armri,
se pot apsa tastele de la 1 la 9, la tasta 1 afindu-se prima alarm, iar la
9 cea mai recent. Pentru vizualizarea simultan a tuturor zonelor care au
fost alarmate, se va apsa tasta 0.
Ieirea din acest mod de afiare se face prin apsarea tastei [#].
Memoria de alarm se va terge odat cu o nou armare a sistemului.
FUNCIA CHIME ON/OFF
[*] [6]
Funcia Chime activat va face ca tastatura s emit 6 "beep"-uri de
fiecare dat cnd o zon ntrziat este activat. Aceat funcie este util
13
CODURILOR DE UTILIZATOR
14
LED DE
ZON
stins
aprins
clipete
CODUL
DE UTILIZATOR ESTE:
neprogramat
programat
n curs de programare
Dup ce s-au fcut toate modificrile dorite, ieirea din acest mod de
programare/modificare se face prin apsarea tastei [#].
OPRIREA
APELRII TELEFONICE
MESAJE VOCALE)
16
DE INSTALATOR]
stins
clipete
aprins
stinse
aprins
clipete
aprins
stinse
17
Cifra HEX:
A
Se introduce [*][0]
D
Se introduce [*][3]
B
Se introduce [*][1]
E
Se introduce [*][4]
C
Se introduce [*][2]
F
Se introduce [*][5]
De remarcat c dup apsarea tastei [*] LED-ul PREGTIT va clipi, iar
dup apsarea cifrei va rmne aprins.
SECIUNILE
DE PROGRAMARE
NUMR DE TELEFON
DE CICLURI DE APELARE
ZONELOR
ZONEI
KEY
20
DE SISTEM
DE INSTALATOR
IESIRILOR PROGRAMABILE
PGM1, PGM2
Se introduc 2 cifre.
Prima cifr se refer la ieirea programabil PGM1, respectiv a doua
cifr la ieirea PGM2 i au semnificaia de mai jos:
[0] ALARM CU MEMORARE
Ieirea se activeaz la producerea unei alarme i se dezactiveaz la
dezarmare ("latch").
[1] URMRIREA STRII SISTEMULUI
Ieirea se activeaz la armare i se dezactiveaz la dezarmare.
[2] TEMPORIZAREA LA INTRARE
Ieirea se activeaz pe perioada temporizrii la intrare.
[3] TEMPORIZAREA LA IESIRE
Ieirea se activeaz pe perioada temporizrii la ieire.
[4] AVARIE
Ieirea se activeaz ct timp n sistem se nregistreaz o avarie (lips reea
de alimentare, lips baterie, comunicare nereuit cu staia de
monitorizare).
[5] SIREN CONTINU
Ieirea se activeaz ct timp este activat sirena n modul Continuu.
[6] SIREN PULSATORIE
Ieirea se activeaz ct timp este activat sirena n modul Pulsatoriu.
[7] SIREN "SILENT"
Ieirea se activeaz ct timp este activat o alarm de tip Silent.
[8] PANIC
Ieirea se activeaz la activarea funciei de Panic (la activarea zonei de
Panic sau la apsarea simultan a tastelor [*]+[#]).
SECIUNEA [14] - MOD
Se introduc 2 cifre:
Prima cifr are semnificaia:
0=apelarea se face n puls;
1=apelarea se face n ton (DTMF);
22
Ambuscad
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
23
Mesajul 2
Mesajul 3
Mesajul 4
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
24
SUMAR PROGRAMARE
[01] PROGRAMAREA PRIMULUI
Implicit: neprogramat
[02] PROGRAMARE
[05] PROGRAMARE
[06] PROGRAMARE
[07] PROGRAMARE
NUMR DE TELEFON
4-LEA
NUMR DE TELEFON
5-LEA
NUMR DE TELEFON
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
CELUI DE-AL
Implicit: neprogramat
3-LEA
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
CELUI DE-AL
Implicit: neprogramat
NUMR DE TELEFON
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
CELUI DE-AL
Implicit: neprogramat
2-LEA
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
CELUI DE-AL
Implicit: neprogramat
[04] PROGRAMARE
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
CELUI DE-AL
Implicit: neprogramat
[03] PROGRAMARE
NUMR DE TELEFON
6-LEA
NUMR DE TELEFON
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
CELUI DE-AL
7-LEA
NUMR DE TELEFON
Implicit: neprogramat
[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]
Implicit:
[0][3][0]
[09] DEFINIREA
[0][0][2]
TIPURILOR ZONELOR
Implicit
Cifra 1
Cifra 2
[0] [0]
[ ][ ]
Zona 1
[0] Intrare/Ieire
[0] continu
[1] [0]
[ ][ ]
Zona 2
[1] Instantanee
[1] pulsatorie
[2] [0]
[ ][ ]
Zona 3
[2] Cu urmrire
[2] silent
[2] [0]
[ ][ ]
Zona 4
[3] 24 ore
25
ZONEI
"KEY"
Implicit
[4] [0]
[ ][ ]
[11] TIMPII
Zona KEY
Cifra 1
Cifra 2
[0] continu
[4] armare/dezarmare
prin cheie
[1] pulsatorie
[2] silent
DE SISTEM
Implicit
[0] [3] [0] [ ] [ ] [ ] Timp de intrare (secunde)
[1] [2] [0] [ ] [ ] [ ] Timp de ieire (secunde)
[0] [0] [4] [ ] [ ] [ ] Timpul de activare a sirenei (minute)
Valorile corecte sunt de la 001 la 255. Nu se va introduce 000.
[12] CODUL
DE INSTALATOR
Implicit
[0] [2] [6] [9]
[ ][ ][ ][ ]
[13] TIPUL
IESIRILOR PROGRAMABILE
Implicit
PGM1, PGM2
Opiuni
[0]
[ ]
ieirea PGM1
[0]
[ ]
ieirea PGM2
[14] MOD
Implicit
Cifra 1
[0] [0]
Cifra 2
[1] trimite mesaj de alarm (zonele 1...4)
[2] trimite mesaj la panic tastatur
[4] trimite mesaj la "AC LOSS" (dup aprox. 4min)
[8] trimite mesaj la Ambuscad
Orice sum ntre cifrele de mai sus pentru a
transmite mai multe mesaje.
[F] trimite toate mesajele.
26
LIMITE
Sistemele de securitate de categoria celor din care face parte i cel pe care vi-l propunem v garanteaz
avertizarea, nu protecia mpotriva efraciei, a incendiului sau a altor situaii extreme. Totui este posibil pentru
orice sistem de alarm, fie el comercial sau instalat ntr-o locuin particular, s nu avertizeze n anumite
situaii, din diverse motive, ca de exemplu:
Infractorii pot avea acces prin zone neprotejate, sau pot avea capacitatea tehnic de a evita un detector
din sistem sau de a deconecta dispozitivul de avertizare.
Detectoarele de efracie (detectoare de prezen n IR pasiv), detectoarele de fum i multe alte dispozitive
de detecie nu funcioneaz dac nu sunt alimentate. Dispozitivele care lucreaz pe baterii nu vor funciona
dac nu au baterii, dac acestea sunt consumate sau dac nu sunt instalate corect. Dispozitivele alimentate la
reeaua de curent alternativ nu vor funciona dac sursa de alimentare este ntrerupt dintr-un motiv sau altul,
chiar i pentru scurt timp.
Semnalele transmise de emitoarele fr fir (wireless) pot fi blocate sau reflectate de obiecte metalice
nainte de a fi recepionate de sistemul de alarm. Chiar dac s-a verificat calea semnalului, regulat, n timpul
testului sptmnal, interpunerea unui obiect metalic n calea semnalului va bloca transmiterea acestuia.
Utilizatorul se poate gsi n situaia n care s nu poat aciona destul de repede un buton de urgen sau
de panic.
n anumite situaii, detectoarele de fum pot s nu reacioneze, din diverse motive, dei ele joac un rol
foarte important n reducerea numrului de decese n incendii izbucnite la locuine particulare. Unele dintre
motivele pentru care detectoarele de fum folosite pe acest sistem nu reacioneaz pot fi: Detectoarele nu sunt
instalate i poziionate corespunztor. Detectoarele nu vor sesiza focul care izbucnete n locuri de unde fumul
nu poate ajunge la detector, cum ar fi emineele, pereii, tavanele sau de partea cealalt a unei ui nchise.
Detectoarele nu vor sesiza incendiile izbucnite pe alte nivele ale cldirii. De exemplu, un detector instalat la
etajul I s-ar putea s nu sesizeze fumul de la un incendiu izbucnit la parter sau subsol. Mai mult dect att,
detectoarele au limitri n detecia fumului.Nici un detector nu poate sesiza orice tip de fum, de fiecare dat. n
general, detectoarele nu vor avertiza asupra incendiilor cauzate de imprudene sau neatenie, cum ar fi: fumatul
n pat, explozii violente, scpri de gaz, depozitare necorespunztoare a materialelor inflamabile, circuite electrice
supuse la suprasarcin, copii nesupravegheai, piromanie. n funcie de natura focului i/sau de poziionarea
detectoarelor, acestea, chiar dac funcioneaz aa cum s-a prevzut iniial, pot s nu avertizeze suficient de
repede, pentru a permite tuturor persoanelor din spaiul protejat s evacueze la timp, pentru a preveni accidentele
sau decesul acestora.
Detectoarele de prezen n IR pasiv vor sesiza efracia numai n raza de aciune conform instruciunilor
de instalare. Ele nu pot asigura o protecie volumetric total a spaiului protejat. Detectoarele de acest tip
creeaz mai multe fascicule de protecie, iar efracia va fi detectat doar n zonele, neobstrucionate, acoperite
de aceste fascicule. Ele nu vor sesiza micarea dincolo de perei, tavane, duumele, ui nchise, perei de
sticl sau ferestre. Protecia mecanic la sabotaj, mascarea, vopsirea sau acoperirea prin pulverizare cu orice
tip de material a oricreia dintre componentele optice ale detectorului poate reduce sensibilitatea acestuia.
Sirenele i sistemele de avertizare pot s nu fie auzite de cealalt parte a unei ui nchise sau parial
deschise. Dac dispozitivul de avertizare sun pe un alt nivel dect sunt poziionate dormitoarele, este posibil
ca acestea s nu fie auzite de persoanele din dormitoare. Este posibil ca semnalul de avertizare s nu fie auzit
chiar de ctre persoanele care nu dorm, n condiiile n care funcioneaz aerul condiionat sau instalaii audio.
De asemenea, este posibil ca dispozitivele de avertizare s nu fie auzite de persoanele care au probleme
auditive sau care dorm profund.
Liniile telefonice necesare pentru transmiterea semnalului de alarm la staia central de monitorizare
pot fi inoperante. Infractorii experimentai pot decupla liniile telefonice excluznd astfel transmiterea la staia de
dispecerat a unei eventuale efracii.
Chiar n situaiile n care sistemul se comport aa cum a fost prevzut, este posibil ca persoanele din
sistemulu protejat s nu aib timp suficient pentru a se proteja. De asemenea, n cazul unui sistem de alarm
monitorizat, exist posibilitatea ca echipele de intervenie s nu ajung n timp util.
Cea mai frecvent cauz a nefuncionrii corespunztoare a unui sistem de alarm este ntreinerea
necorespunztoare. Sistemul va trebui testat sptmnal pentru a verifica funcionarea corespunztoare a
detectoarelor.
CARACTERISTICI TEHNICE
Numr de zone
Tipul zonelor
Rezistena de nchidere a zonei
Ieiri programabile PGM1 i PGM2
Sarcina maxim a ieirilor PGM1 i PGM2
Consum tipic al plcii centralei (stand-by)
Consum tipic al tastaturii
Tensiunea nominal de funcionare a plcii
S.A.
4 + 1 zona Tamper
programabile
2,2kOhm
2
100mA
35mA
12mA