SISTEME DE MONITORIZARE, ACHIZIIE A DATELOR I CONTROL
(SCADA)
N STAIA DE EPURARE DE LA S.C. COMCEH S.A. CLRAI
Grigore VLAD, Bogdan HUMOREANU, Ciprian POP
S.C. ICPE Bistria S.A., Bistria, Romnia
Abstract: Supervisory control and data acquisition (SCADA) systems in the purging station of
trading
CO. COMCEH S.A. Clrai. In the complex system of interaction between the environment
and the
industrial processes some of the most important aspects still debating, consist in efficient resource
consumption and diminishing the impact the industrial activities have upon the environment. By
taking
advantage of the newest technological achievements, these interactions are brought to a new level, by
successful implementations of powerful control method and process analysis instruments. In the
present
material, we will have a look at a residual water treatment process at Comceh S.A. Clrai, where
we have a
case of successful implementation of SCADA system and modern online process analysis devices.
Key words: SCADA systems, industrial water treatment, water treatment efficiency
Introducere
Din punct de vedere tehnologic, procesul de epurare a apelor industriale de la Comceh S.A.
Clrai are la baz dou etape principale distincte, respectiv treapta fizico-chimic i
treapta
biologic. n proces apare o etap secundar de recirculare prin care se realizeaz
recuperarea unor
nsemnate cantiti de ap pentru procesul de producie. Msurarea
parametrilor de ieire se
realizeaz prin intermediul unei reele de traductoare de mrimi de proces,
conectate la instalaia de
automatizare. Capacitatea proiectat a staiei este de 4800 m.c. pe zi, la ieire
apele trebuind s fie
conforme NTPA 001, pentru a putea fi deversate n emisar.
Instalaia de automatizare se structureaz n jurul automatului programabil principal
care
conduce n mod automat procesul de epurare, de la nivel ierarhic primar. n structura
sistemului
exist i un automat programabil subordonat ierarhic celui principal, care
gestioneaz buna
funcionare a staiei de pompare. La nivel ierarhic superior, se afl sistemul de achiziie a
datelor,
supervizare i control (SCADA), care este interconectat la nivel informatic cu memoria
intern a
automatelor programabile din proces i care permite conducerea
automat a procesului, att la nivel
local, de la staia principal cu rol de server, ct i de la distan [1].
Arhitectura sistemului
Elementele componente principale ale sistemului de automatizare sunt prezentate n fig.1.
Fig. 1. Arhitectura sistemului de automatizare
Ecoterra, no. 26, 2011
162
Funciile sistemului SCADA
de valori. Aceste rapoarte sunt stocate pe hard-disk-ul staiei server, ca fiiere n format
.rtf,
fiecare fiier coninnd cte un raport [4].
Din punct de vedere al interfeei, aplicaia SCADA are ca punct de plecare o schem
sinoptic a ntregului proces, prin intermediul creia operatorul poate s
identifice cu uurin starea
n care se afl att procesul tehnologic, ct i elementele componente ale acestuia (fig. 2).
Prin
intermediul elementelor interactive de control se pot accesa direct diferitele zone de interes
ale
aplicaiei, respectiv lista de alarme (fig. 3), seciunea dedicat graficelor de
proces (fig. 4), seciunea
dedicat modificrilor parametrilor tehnologici, sau seciunea dedicat
vizualizrilor de rapoarte de
activitate. Corespunztor fiecrui subproces, seciunea dedicat graficelor
ofer posibilitatea
vizualizrii predefinite a anumitor grupuri de mrimi, n scopul evidenierii
interdependenelor ntre
acestea, pe perioade corespunztoare de timp. Aceste vizualizri sunt
accesibile prin intermediul
butoanelor de acces rapid [3].
Ecoterra, no. 26, 2011
163
Fig. 2. Pagina principal
Fig. 3. Lista de alarme
Fig. 4. Pagina cu grafice de proces
Ecoterra, no. 26, 2011
164
Concluzii
Utilizarea de aplicaii de tip SCADA n procesele de automatizare aduce
importante
beneficii n ceea ce privete eficiena i utilizarea n exploatare, mai ales n cazul
proceselor
tehnologice de epurare a apelor uzate, situaii n care este vital urmrirea pe
termen lung a
variaiilor parametrilor de proces. Datorit posibilitii de intervenie
asupra procesului, de la nivel
ierarhic superior, se pot elabora metode specifice de control, n scopul minimizrii
resurselor
implicate n procesul de epurare. Un bun exemplu n acest scop este oferit de posibilitatea de
modificare a parametrilor algoritmului de control PID implementat la controlul suflantelor
astfel
nct s rezulte o maximizare a eficienei utilitzii acestora.
Bibliografie
1. *** Datasheet Catalog.Com - Catalog internet componente electronice-Tranzistor
MOSFET
IRF840PBF
2. *** Datasheet Catalog.Com - Catalog internet componente electronice - Circuit integrat
UC2825
3. *** DatasheetCatalog.Com - Catalog internet componente electronice - IR 2113
4. *** www.automatizari-scada.ro
Date de contact
Grigore VLAD: S.C. ICPE Bistria S.A., str. Parcului, nr. 7, 420035, Bistria,
jud. Bistria-Nsud,
Romnia, e-mail: icpe@icpebn.ro